Design, fabricating, and calibration of a new personal dosimeter

This study aimed to produce a personal dosimeter to connect the electronic devices to transfer the dosimetry data online including dose rate data and integral dose. At first, an electronic board was designed. Afterwards, the board was simulated using Altium Designer software. Then, the microcontroll...

Full description

Bibliographic Details
Main Authors: M. Zolghadr, S.M.M. Abtahi, K. Sepanloo, E. Zarifie
Format: Article
Language:fas
Published: Nuclear Science and Technology Research Institute 2021-04-01
Series:مجله علوم و فنون هسته‌ای
Subjects:
Online Access:https://jonsat.nstri.ir/article_1193_6186e9684f6e899aa1b1b72551a35287.pdf
_version_ 1797835415182376960
author M. Zolghadr
S.M.M. Abtahi
K. Sepanloo
E. Zarifie
author_facet M. Zolghadr
S.M.M. Abtahi
K. Sepanloo
E. Zarifie
author_sort M. Zolghadr
collection DOAJ
description This study aimed to produce a personal dosimeter to connect the electronic devices to transfer the dosimetry data online including dose rate data and integral dose. At first, an electronic board was designed. Afterwards, the board was simulated using Altium Designer software. Then, the microcontroller programming was performed using Code Vision software. The performance of the elements was tested using Proteus Design Suite software and the circuit diagnosis and testing were practically implemented. Afterwards, the calibration factor and the count-to-dose conversion coefficient were obtained using an ionization chamber in the Secondary Standard Dosimetry Laboratory of Iran. Furthermore, dose distribution as a function of distance to the source, was obtained using the produced dosimeter and was compared using a calibrated ionization chamber. To this purpose, an unmitigated Cs-137 source, a Cs-137 source with a 22 mm Pb shield, and a Cs-137 source with a 22 mm plus 18 mm shield were used. The results showed a calibration factor of 0.99 ± 0.02 for the designed dosimeter. Calibration results showed that the produced dosimeter passed the ISO/IEC 17025:2005 criteria. Furthermore, the dose distribution results demonstrated negligible differences of less than 0.01% between the produced dosimeter and the reference ionization chamber. It was concluded that the produced dosimeter could be used as a reference and standard dosimeter in laboratories, for monitoring and dosimetry of ionizing photon radiations.
first_indexed 2024-04-09T14:53:38Z
format Article
id doaj.art-d6851a6781dd4ce2a75d9f4bd1cb065d
institution Directory Open Access Journal
issn 1735-1871
2676-5861
language fas
last_indexed 2024-04-09T14:53:38Z
publishDate 2021-04-01
publisher Nuclear Science and Technology Research Institute
record_format Article
series مجله علوم و فنون هسته‌ای
spelling doaj.art-d6851a6781dd4ce2a75d9f4bd1cb065d2023-05-02T09:06:30ZfasNuclear Science and Technology Research Instituteمجله علوم و فنون هسته‌ای1735-18712676-58612021-04-0142112313010.24200/nst.2021.11931193Design, fabricating, and calibration of a new personal dosimeterM. Zolghadr0S.M.M. Abtahi1K. Sepanloo2E. Zarifie3Physics Department, Basic Science Faculty, Imam Khomeini International University, P.O. Box: 3414896818, Qazvin, IranPhysics Department, Basic Science Faculty, Imam Khomeini International University, P.O. Box: 3414896818, Qazvin, IranReactor and Nuclear Safety Research School, Nuclear Science and Technology Research Institute, P.O.Box: 14155-1339, Tehran - IranReactor and Nuclear Safety Research School, Nuclear Science and Technology Research Institute, P.O.Box: 14155-1339, Tehran - IranThis study aimed to produce a personal dosimeter to connect the electronic devices to transfer the dosimetry data online including dose rate data and integral dose. At first, an electronic board was designed. Afterwards, the board was simulated using Altium Designer software. Then, the microcontroller programming was performed using Code Vision software. The performance of the elements was tested using Proteus Design Suite software and the circuit diagnosis and testing were practically implemented. Afterwards, the calibration factor and the count-to-dose conversion coefficient were obtained using an ionization chamber in the Secondary Standard Dosimetry Laboratory of Iran. Furthermore, dose distribution as a function of distance to the source, was obtained using the produced dosimeter and was compared using a calibrated ionization chamber. To this purpose, an unmitigated Cs-137 source, a Cs-137 source with a 22 mm Pb shield, and a Cs-137 source with a 22 mm plus 18 mm shield were used. The results showed a calibration factor of 0.99 ± 0.02 for the designed dosimeter. Calibration results showed that the produced dosimeter passed the ISO/IEC 17025:2005 criteria. Furthermore, the dose distribution results demonstrated negligible differences of less than 0.01% between the produced dosimeter and the reference ionization chamber. It was concluded that the produced dosimeter could be used as a reference and standard dosimeter in laboratories, for monitoring and dosimetry of ionizing photon radiations.https://jonsat.nstri.ir/article_1193_6186e9684f6e899aa1b1b72551a35287.pdfpersonal dosimeterdosimetrygeiger mullercalibration
spellingShingle M. Zolghadr
S.M.M. Abtahi
K. Sepanloo
E. Zarifie
Design, fabricating, and calibration of a new personal dosimeter
مجله علوم و فنون هسته‌ای
personal dosimeter
dosimetry
geiger muller
calibration
title Design, fabricating, and calibration of a new personal dosimeter
title_full Design, fabricating, and calibration of a new personal dosimeter
title_fullStr Design, fabricating, and calibration of a new personal dosimeter
title_full_unstemmed Design, fabricating, and calibration of a new personal dosimeter
title_short Design, fabricating, and calibration of a new personal dosimeter
title_sort design fabricating and calibration of a new personal dosimeter
topic personal dosimeter
dosimetry
geiger muller
calibration
url https://jonsat.nstri.ir/article_1193_6186e9684f6e899aa1b1b72551a35287.pdf
work_keys_str_mv AT mzolghadr designfabricatingandcalibrationofanewpersonaldosimeter
AT smmabtahi designfabricatingandcalibrationofanewpersonaldosimeter
AT ksepanloo designfabricatingandcalibrationofanewpersonaldosimeter
AT ezarifie designfabricatingandcalibrationofanewpersonaldosimeter