Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi

The demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency...

Full description

Bibliographic Details
Main Authors: Melingga lingga, Abdul Azis, Irine Kartika Pebrianti
Format: Article
Language:Indonesian
Published: Universitas Semarang 2021-11-01
Series:Elektrika
Subjects:
Online Access:https://journals.usm.ac.id/index.php/elektrika/article/view/3707
_version_ 1797448218326335488
author Melingga lingga
Abdul Azis
Irine Kartika Pebrianti
author_facet Melingga lingga
Abdul Azis
Irine Kartika Pebrianti
author_sort Melingga lingga
collection DOAJ
description The demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency response before load shedding, to calculate the frequency response after load shedding and to analyze the load recovery after normal frequency in the load. The methods to be used in writing and discussing this research are: Observation Method, Interview Method / Interview, Literature Study Method. Based on the calculation of the data in the previous chapter, the following conclusions can be drawn, the calculation of the conditions before carrying out the load shedding is based on the rate of decreasing frequency from the result obtained is 1.6 Hz / s, then to calculate the time used in determining the frequency at the time of load shedding then the results obtained are 54 Hz, Meanwhile, to calculate the frequency after load shedding that is obtained is 49.1 Hz, Calculation of load shedding time is expected when there is a decrease in frequency of 10.5 seconds, Calculation of the load rate of increase expected after load shedding then the optimal load value that must be removed is 5.55 w.
first_indexed 2024-03-09T14:07:17Z
format Article
id doaj.art-d6c5021c18394216ba18ad6caf48c39f
institution Directory Open Access Journal
issn 2085-0565
language Indonesian
last_indexed 2024-03-09T14:07:17Z
publishDate 2021-11-01
publisher Universitas Semarang
record_format Article
series Elektrika
spelling doaj.art-d6c5021c18394216ba18ad6caf48c39f2023-11-30T03:58:46ZindUniversitas SemarangElektrika2085-05652021-11-01132717310.26623/elektrika.v13i2.37072132Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan FrekuensiMelingga lingga0Abdul Azis1Irine Kartika Pebrianti2Program Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangProgram Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangProgram Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangThe demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency response before load shedding, to calculate the frequency response after load shedding and to analyze the load recovery after normal frequency in the load. The methods to be used in writing and discussing this research are: Observation Method, Interview Method / Interview, Literature Study Method. Based on the calculation of the data in the previous chapter, the following conclusions can be drawn, the calculation of the conditions before carrying out the load shedding is based on the rate of decreasing frequency from the result obtained is 1.6 Hz / s, then to calculate the time used in determining the frequency at the time of load shedding then the results obtained are 54 Hz, Meanwhile, to calculate the frequency after load shedding that is obtained is 49.1 Hz, Calculation of load shedding time is expected when there is a decrease in frequency of 10.5 seconds, Calculation of the load rate of increase expected after load shedding then the optimal load value that must be removed is 5.55 w.https://journals.usm.ac.id/index.php/elektrika/article/view/3707load shedding, decrease in frequency, electric power generation
spellingShingle Melingga lingga
Abdul Azis
Irine Kartika Pebrianti
Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
Elektrika
load shedding, decrease in frequency, electric power generation
title Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
title_full Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
title_fullStr Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
title_full_unstemmed Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
title_short Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
title_sort studi pelepasan beban pada pltu keramasan saat terjadi penurunan frekuensi
topic load shedding, decrease in frequency, electric power generation
url https://journals.usm.ac.id/index.php/elektrika/article/view/3707
work_keys_str_mv AT melinggalingga studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi
AT abdulazis studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi
AT irinekartikapebrianti studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi