Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi
The demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Universitas Semarang
2021-11-01
|
Series: | Elektrika |
Subjects: | |
Online Access: | https://journals.usm.ac.id/index.php/elektrika/article/view/3707 |
_version_ | 1797448218326335488 |
---|---|
author | Melingga lingga Abdul Azis Irine Kartika Pebrianti |
author_facet | Melingga lingga Abdul Azis Irine Kartika Pebrianti |
author_sort | Melingga lingga |
collection | DOAJ |
description | The demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency response before load shedding, to calculate the frequency response after load shedding and to analyze the load recovery after normal frequency in the load. The methods to be used in writing and discussing this research are: Observation Method, Interview Method / Interview, Literature Study Method. Based on the calculation of the data in the previous chapter, the following conclusions can be drawn, the calculation of the conditions before carrying out the load shedding is based on the rate of decreasing frequency from the result obtained is 1.6 Hz / s, then to calculate the time used in determining the frequency at the time of load shedding then the results obtained are 54 Hz, Meanwhile, to calculate the frequency after load shedding that is obtained is 49.1 Hz, Calculation of load shedding time is expected when there is a decrease in frequency of 10.5 seconds, Calculation of the load rate of increase expected after load shedding then the optimal load value that must be removed is 5.55 w. |
first_indexed | 2024-03-09T14:07:17Z |
format | Article |
id | doaj.art-d6c5021c18394216ba18ad6caf48c39f |
institution | Directory Open Access Journal |
issn | 2085-0565 |
language | Indonesian |
last_indexed | 2024-03-09T14:07:17Z |
publishDate | 2021-11-01 |
publisher | Universitas Semarang |
record_format | Article |
series | Elektrika |
spelling | doaj.art-d6c5021c18394216ba18ad6caf48c39f2023-11-30T03:58:46ZindUniversitas SemarangElektrika2085-05652021-11-01132717310.26623/elektrika.v13i2.37072132Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan FrekuensiMelingga lingga0Abdul Azis1Irine Kartika Pebrianti2Program Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangProgram Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangProgram Studi Teknik Elektro, Fakultas Teknik, Universitas PGRI PalembangThe demand for electric power increases along with the development of technological progress and development. The use of electricity is an important factor in people's lives, both in households, lighting, communication, and industrial. The purpose of this research is to calculate the frequency response before load shedding, to calculate the frequency response after load shedding and to analyze the load recovery after normal frequency in the load. The methods to be used in writing and discussing this research are: Observation Method, Interview Method / Interview, Literature Study Method. Based on the calculation of the data in the previous chapter, the following conclusions can be drawn, the calculation of the conditions before carrying out the load shedding is based on the rate of decreasing frequency from the result obtained is 1.6 Hz / s, then to calculate the time used in determining the frequency at the time of load shedding then the results obtained are 54 Hz, Meanwhile, to calculate the frequency after load shedding that is obtained is 49.1 Hz, Calculation of load shedding time is expected when there is a decrease in frequency of 10.5 seconds, Calculation of the load rate of increase expected after load shedding then the optimal load value that must be removed is 5.55 w.https://journals.usm.ac.id/index.php/elektrika/article/view/3707load shedding, decrease in frequency, electric power generation |
spellingShingle | Melingga lingga Abdul Azis Irine Kartika Pebrianti Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi Elektrika load shedding, decrease in frequency, electric power generation |
title | Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi |
title_full | Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi |
title_fullStr | Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi |
title_full_unstemmed | Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi |
title_short | Studi Pelepasan Beban Pada PLTU Keramasan Saat Terjadi Penurunan Frekuensi |
title_sort | studi pelepasan beban pada pltu keramasan saat terjadi penurunan frekuensi |
topic | load shedding, decrease in frequency, electric power generation |
url | https://journals.usm.ac.id/index.php/elektrika/article/view/3707 |
work_keys_str_mv | AT melinggalingga studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi AT abdulazis studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi AT irinekartikapebrianti studipelepasanbebanpadapltukeramasansaatterjadipenurunanfrekuensi |