Power Injection on Single Phase Grid System

This paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of...

Full description

Bibliographic Details
Main Authors: Fauzan Ismail, Asnal Effendi, witrionanda witrionanda
Format: Article
Language:Indonesian
Published: Department of Electrical Engineering, Faculty of Engineering, Tanjungpura University 2019-09-01
Series:Elkha: Jurnal Teknik Elektro
Subjects:
Online Access:http://jurnal.untan.ac.id/index.php/Elkha/article/view/30932
_version_ 1811207450810908672
author Fauzan Ismail
Asnal Effendi
witrionanda witrionanda
author_facet Fauzan Ismail
Asnal Effendi
witrionanda witrionanda
author_sort Fauzan Ismail
collection DOAJ
description This paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of inverter becomes a feedback (IL). Both current are derived to produce PWM using current mode controller method. As long as the grid system on fault condition like voltage distortion, therefore the single-phase inverter that connected into the grid should change the role and keep stabilization. The voltages sag and swell are the possible conditions that occurred on a power system. Voltage Sag is an event where the line voltage decreases from the nominal line-voltage for a short period of time. Voltage swell is the event when the line voltage increase from the nominal line voltage. By using PSIM software, the injection and absorption of power into a grid system is verified during a voltage sag, swell, and normal. The simulation shows voltage grid vg, current inverter iinv, current grid, active power P, reactive power Q. The waveform of the measured parameter is analized to define the role of inverter toward grid. the The result shows performance of the proposed inverter to absorb reactive power during swell, and inject reactive power when sagging.
first_indexed 2024-04-12T04:04:28Z
format Article
id doaj.art-d6e63dac91854770a12fea7c2a1e4464
institution Directory Open Access Journal
issn 1858-1463
2580-6807
language Indonesian
last_indexed 2024-04-12T04:04:28Z
publishDate 2019-09-01
publisher Department of Electrical Engineering, Faculty of Engineering, Tanjungpura University
record_format Article
series Elkha: Jurnal Teknik Elektro
spelling doaj.art-d6e63dac91854770a12fea7c2a1e44642022-12-22T03:48:39ZindDepartment of Electrical Engineering, Faculty of Engineering, Tanjungpura UniversityElkha: Jurnal Teknik Elektro1858-14632580-68072019-09-01111475210.26418/elkha.v11i1.3093224340Power Injection on Single Phase Grid SystemFauzan Ismail0Asnal Effendi1witrionanda witrionanda2Power Electronics and Renewable EnergyPower EngineeringTeknik Tenaga ListrikThis paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of inverter becomes a feedback (IL). Both current are derived to produce PWM using current mode controller method. As long as the grid system on fault condition like voltage distortion, therefore the single-phase inverter that connected into the grid should change the role and keep stabilization. The voltages sag and swell are the possible conditions that occurred on a power system. Voltage Sag is an event where the line voltage decreases from the nominal line-voltage for a short period of time. Voltage swell is the event when the line voltage increase from the nominal line voltage. By using PSIM software, the injection and absorption of power into a grid system is verified during a voltage sag, swell, and normal. The simulation shows voltage grid vg, current inverter iinv, current grid, active power P, reactive power Q. The waveform of the measured parameter is analized to define the role of inverter toward grid. the The result shows performance of the proposed inverter to absorb reactive power during swell, and inject reactive power when sagging.http://jurnal.untan.ac.id/index.php/Elkha/article/view/30932power injection, grid connected, photovoltaics, renewable energy, voltage sag and swell.
spellingShingle Fauzan Ismail
Asnal Effendi
witrionanda witrionanda
Power Injection on Single Phase Grid System
Elkha: Jurnal Teknik Elektro
power injection, grid connected, photovoltaics, renewable energy, voltage sag and swell.
title Power Injection on Single Phase Grid System
title_full Power Injection on Single Phase Grid System
title_fullStr Power Injection on Single Phase Grid System
title_full_unstemmed Power Injection on Single Phase Grid System
title_short Power Injection on Single Phase Grid System
title_sort power injection on single phase grid system
topic power injection, grid connected, photovoltaics, renewable energy, voltage sag and swell.
url http://jurnal.untan.ac.id/index.php/Elkha/article/view/30932
work_keys_str_mv AT fauzanismail powerinjectiononsinglephasegridsystem
AT asnaleffendi powerinjectiononsinglephasegridsystem
AT witrionandawitrionanda powerinjectiononsinglephasegridsystem