A fault-tolerance topology of three-level four-leg NPC inverter
In view of problem that it is difficult to accurately locate device failure of inverter, a fault tolerance topology of three-level four-leg NPC inverter was proposed. In the topology, short-circuit fault and open-circuit fault can be located accurately by switching device used when topology changes,...
Main Authors: | , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2016-10-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2016.10.016 |
Summary: | In view of problem that it is difficult to accurately locate device failure of inverter, a fault tolerance topology of three-level four-leg NPC inverter was proposed. In the topology, short-circuit fault and open-circuit fault can be located accurately by switching device used when topology changes, so as to provide a basis for fault-tolerant control of inverter. The topology enables half-leg replacement, and can achieve fault-tolerant control of up to three inverter legs at the same time. |
---|---|