Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation
Purpose: We describe a rare case of tube obstruction caused by intraocular lens (IOL) capture following a PreserFlo MicroShunt (PMS) surgery and its subsequent management. Observations: Tube obstruction was noted following PMS implantation at 8 days postoperatively. The intraocular pressure (IOP) in...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2024-03-01
|
Series: | American Journal of Ophthalmology Case Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2451993623001597 |
_version_ | 1797301417922265088 |
---|---|
author | Kentaro Iwasaki Shogo Arimura Masaru Inatani |
author_facet | Kentaro Iwasaki Shogo Arimura Masaru Inatani |
author_sort | Kentaro Iwasaki |
collection | DOAJ |
description | Purpose: We describe a rare case of tube obstruction caused by intraocular lens (IOL) capture following a PreserFlo MicroShunt (PMS) surgery and its subsequent management. Observations: Tube obstruction was noted following PMS implantation at 8 days postoperatively. The intraocular pressure (IOP) increased to 42 mmHg because of tube occlusion that was caused by iris and IOL capture at the tip of the tube. The occlusion was released surgically to free the lumen, and the IOP rapidly decreased to 14 mmHg. Conclusions and importance: IOP elevation due to tube obstruction caused by iris and IOL capture after PMS surgery was resolved by surgical intervention without tube reinsertion. Extra care is required regarding the IOL position in relation to the PMS tube when hypotony occurs in the early postoperative period. |
first_indexed | 2024-03-07T23:22:17Z |
format | Article |
id | doaj.art-d7bcd49e76b744169b79045c25b294b3 |
institution | Directory Open Access Journal |
issn | 2451-9936 |
language | English |
last_indexed | 2024-03-07T23:22:17Z |
publishDate | 2024-03-01 |
publisher | Elsevier |
record_format | Article |
series | American Journal of Ophthalmology Case Reports |
spelling | doaj.art-d7bcd49e76b744169b79045c25b294b32024-02-21T05:29:09ZengElsevierAmerican Journal of Ophthalmology Case Reports2451-99362024-03-0133101951Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantationKentaro Iwasaki0Shogo Arimura1Masaru Inatani2Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Fukui, JapanDepartment of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Fukui, JapanCorresponding author. Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Eiheiji, Yoshida, Fukui 910-1193, Japan.; Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Fukui, JapanPurpose: We describe a rare case of tube obstruction caused by intraocular lens (IOL) capture following a PreserFlo MicroShunt (PMS) surgery and its subsequent management. Observations: Tube obstruction was noted following PMS implantation at 8 days postoperatively. The intraocular pressure (IOP) increased to 42 mmHg because of tube occlusion that was caused by iris and IOL capture at the tip of the tube. The occlusion was released surgically to free the lumen, and the IOP rapidly decreased to 14 mmHg. Conclusions and importance: IOP elevation due to tube obstruction caused by iris and IOL capture after PMS surgery was resolved by surgical intervention without tube reinsertion. Extra care is required regarding the IOL position in relation to the PMS tube when hypotony occurs in the early postoperative period.http://www.sciencedirect.com/science/article/pii/S2451993623001597PreserFloMicroShuntGlaucoma drainage deviceObstructionMinimally invasive glaucoma surgery |
spellingShingle | Kentaro Iwasaki Shogo Arimura Masaru Inatani Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation American Journal of Ophthalmology Case Reports PreserFlo MicroShunt Glaucoma drainage device Obstruction Minimally invasive glaucoma surgery |
title | Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation |
title_full | Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation |
title_fullStr | Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation |
title_full_unstemmed | Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation |
title_short | Tube obstruction caused by intraocular lens capture following PreserFlo MicroShunt implantation |
title_sort | tube obstruction caused by intraocular lens capture following preserflo microshunt implantation |
topic | PreserFlo MicroShunt Glaucoma drainage device Obstruction Minimally invasive glaucoma surgery |
url | http://www.sciencedirect.com/science/article/pii/S2451993623001597 |
work_keys_str_mv | AT kentaroiwasaki tubeobstructioncausedbyintraocularlenscapturefollowingpreserflomicroshuntimplantation AT shogoarimura tubeobstructioncausedbyintraocularlenscapturefollowingpreserflomicroshuntimplantation AT masaruinatani tubeobstructioncausedbyintraocularlenscapturefollowingpreserflomicroshuntimplantation |