Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial

Introduction: There are many available Nickel Titanium (Ni-Ti) rotary systems that are used for canal cleaning and shaping of the permanent teeth. The new emerging concept in pediatric dentistry is the use of rotary files for canal instrumentation in primary teeth. In literature, there are no clinic...

Full description

Bibliographic Details
Main Authors: Sofiya Juliet, Ganesh Jeevanandan, Lavanya Govindaraju, Vignesh Ravindran, Erulappan Muthuganapathy Subramanian
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Journal of Orofacial Sciences
Subjects:
Online Access:http://www.jofs.in/article.asp?issn=0975-8844;year=2020;volume=12;issue=1;spage=30;epage=34;aulast=Juliet
_version_ 1818026600250212352
author Sofiya Juliet
Ganesh Jeevanandan
Lavanya Govindaraju
Vignesh Ravindran
Erulappan Muthuganapathy Subramanian
author_facet Sofiya Juliet
Ganesh Jeevanandan
Lavanya Govindaraju
Vignesh Ravindran
Erulappan Muthuganapathy Subramanian
author_sort Sofiya Juliet
collection DOAJ
description Introduction: There are many available Nickel Titanium (Ni-Ti) rotary systems that are used for canal cleaning and shaping of the permanent teeth. The new emerging concept in pediatric dentistry is the use of rotary files for canal instrumentation in primary teeth. In literature, there are no clinical studies comparing three different rotary systems in primary teeth. The aim of this study was to compare and evaluate the quality of obturation and instrumentation time using three rotary file systems in primary mandibular molars. Materials and Methods: A total of 45 primary mandibular molars were included in the study and were randomly allotted to one of the three groups. Group 1: ProTaper files; Group 2 Kedo-S files and Group 3: RaCe files. Standardized digital radiographs were taken to the assess quality of obturation as underfill, optimal fill and overfill. Statistical analysis was done using SPSS software version 17.0. An intergroup comparison of the quality of obturation and instrumentation time was done using Chi-square test and ANOVA with the level of significance set at 0.05. Results: No significant difference was observed in the quality of obturation among the three groups (P = 0.661). However, a statistically significant was noted in the instrumentation time among the groups (P < 0.05). In Kedo-S files group 80% of the teeth were optimally filled followed by 60% in ProTaper files and 46.67 % in RaCe files group. The instrumentation time was least in RaCe files 31.67 secs followed by ProTaper files 45.93 secs and Kedo-S (78.53 secs). Conclusion: No significant difference was noted with respect to quality of obturation using S2 ProTaper files, Kedo-S files and RaCe files in primary teeth. There was a significant difference in instrumentation time among the three groups with least working time with RaCe files.
first_indexed 2024-12-10T04:34:35Z
format Article
id doaj.art-d7c202b3aad343f1bf06ca9c30fdaeee
institution Directory Open Access Journal
issn 0975-8844
language English
last_indexed 2024-12-10T04:34:35Z
publishDate 2020-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Orofacial Sciences
spelling doaj.art-d7c202b3aad343f1bf06ca9c30fdaeee2022-12-22T02:02:02ZengWolters Kluwer Medknow PublicationsJournal of Orofacial Sciences0975-88442020-01-01121303410.4103/jofs.jofs_99_18Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled TrialSofiya JulietGanesh JeevanandanLavanya GovindarajuVignesh RavindranErulappan Muthuganapathy SubramanianIntroduction: There are many available Nickel Titanium (Ni-Ti) rotary systems that are used for canal cleaning and shaping of the permanent teeth. The new emerging concept in pediatric dentistry is the use of rotary files for canal instrumentation in primary teeth. In literature, there are no clinical studies comparing three different rotary systems in primary teeth. The aim of this study was to compare and evaluate the quality of obturation and instrumentation time using three rotary file systems in primary mandibular molars. Materials and Methods: A total of 45 primary mandibular molars were included in the study and were randomly allotted to one of the three groups. Group 1: ProTaper files; Group 2 Kedo-S files and Group 3: RaCe files. Standardized digital radiographs were taken to the assess quality of obturation as underfill, optimal fill and overfill. Statistical analysis was done using SPSS software version 17.0. An intergroup comparison of the quality of obturation and instrumentation time was done using Chi-square test and ANOVA with the level of significance set at 0.05. Results: No significant difference was observed in the quality of obturation among the three groups (P = 0.661). However, a statistically significant was noted in the instrumentation time among the groups (P < 0.05). In Kedo-S files group 80% of the teeth were optimally filled followed by 60% in ProTaper files and 46.67 % in RaCe files group. The instrumentation time was least in RaCe files 31.67 secs followed by ProTaper files 45.93 secs and Kedo-S (78.53 secs). Conclusion: No significant difference was noted with respect to quality of obturation using S2 ProTaper files, Kedo-S files and RaCe files in primary teeth. There was a significant difference in instrumentation time among the three groups with least working time with RaCe files.http://www.jofs.in/article.asp?issn=0975-8844;year=2020;volume=12;issue=1;spage=30;epage=34;aulast=Julietpediatric rotary filesprimary molarspulpectomyrandomized controlled trial
spellingShingle Sofiya Juliet
Ganesh Jeevanandan
Lavanya Govindaraju
Vignesh Ravindran
Erulappan Muthuganapathy Subramanian
Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
Journal of Orofacial Sciences
pediatric rotary files
primary molars
pulpectomy
randomized controlled trial
title Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
title_full Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
title_fullStr Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
title_full_unstemmed Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
title_short Comparison Between Three Rotary Files on Quality of Obturation and Instrumentation Time in Primary Teeth − A Double Blinded Randomized Controlled Trial
title_sort comparison between three rotary files on quality of obturation and instrumentation time in primary teeth a double blinded randomized controlled trial
topic pediatric rotary files
primary molars
pulpectomy
randomized controlled trial
url http://www.jofs.in/article.asp?issn=0975-8844;year=2020;volume=12;issue=1;spage=30;epage=34;aulast=Juliet
work_keys_str_mv AT sofiyajuliet comparisonbetweenthreerotaryfilesonqualityofobturationandinstrumentationtimeinprimaryteethadoubleblindedrandomizedcontrolledtrial
AT ganeshjeevanandan comparisonbetweenthreerotaryfilesonqualityofobturationandinstrumentationtimeinprimaryteethadoubleblindedrandomizedcontrolledtrial
AT lavanyagovindaraju comparisonbetweenthreerotaryfilesonqualityofobturationandinstrumentationtimeinprimaryteethadoubleblindedrandomizedcontrolledtrial
AT vigneshravindran comparisonbetweenthreerotaryfilesonqualityofobturationandinstrumentationtimeinprimaryteethadoubleblindedrandomizedcontrolledtrial
AT erulappanmuthuganapathysubramanian comparisonbetweenthreerotaryfilesonqualityofobturationandinstrumentationtimeinprimaryteethadoubleblindedrandomizedcontrolledtrial