Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon<inline-formula><math xmlns="...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-07-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/22/15/5628 |
_version_ | 1797412322026717184 |
---|---|
author | Pauline Morin Antoine Muller Charles Pontonnier Georges Dumont |
author_facet | Pauline Morin Antoine Muller Charles Pontonnier Georges Dumont |
author_sort | Pauline Morin |
collection | DOAJ |
description | Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mi>®</mi></msup></semantics></math></inline-formula> pressure insoles during sidestep cuts, runs and walks. The CoP positions assessed from force platform data and from pressure insole data were compared. One calibration trial performed on the force platforms was used to localize the insoles in the reference coordinate system. The most accurate results were obtained when the motion performed during the calibration trial was similar to the motion under study. In such a case, mean accuracy of CoP position have been evaluated to <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>15</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>4</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along anteroposterior (AP) axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>8.5</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>3</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along mediolateral (ML) axis for sidestep cuts, <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>18</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>5</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along AP axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>7.3</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>4</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along ML axis for runs, <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>15</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>6</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along AP axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>6.6</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>3</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along ML axis for walks. The accuracy of the CoP position assesment from pressure insole data increased with the vertical force applied to the pressure insole and with the number of pressure cells involved. |
first_indexed | 2024-03-09T05:00:31Z |
format | Article |
id | doaj.art-d7f87dd3268f4cbf8100748e6de5355a |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-09T05:00:31Z |
publishDate | 2022-07-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-d7f87dd3268f4cbf8100748e6de5355a2023-12-03T13:00:37ZengMDPI AGSensors1424-82202022-07-012215562810.3390/s22155628Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and WalksPauline Morin0Antoine Muller1Charles Pontonnier2Georges Dumont3University Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, FranceUniversity Lyon, University Gustave Eiffel, University Claude Bernard Lyon 1, LBMC UMR_T 9406, 69622 Lyon, FranceUniversity Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, FranceUniversity Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, FranceEstimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mi>®</mi></msup></semantics></math></inline-formula> pressure insoles during sidestep cuts, runs and walks. The CoP positions assessed from force platform data and from pressure insole data were compared. One calibration trial performed on the force platforms was used to localize the insoles in the reference coordinate system. The most accurate results were obtained when the motion performed during the calibration trial was similar to the motion under study. In such a case, mean accuracy of CoP position have been evaluated to <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>15</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>4</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along anteroposterior (AP) axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>8.5</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>3</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along mediolateral (ML) axis for sidestep cuts, <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>18</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>5</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along AP axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>7.3</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>4</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along ML axis for runs, <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>15</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>6</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along AP axis and <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>6.6</mn><mspace width="3.33333pt"></mspace><mo>±</mo><mspace width="3.33333pt"></mspace><mn>3</mn><mspace width="3.33333pt"></mspace></mrow></semantics></math></inline-formula>mm along ML axis for walks. The accuracy of the CoP position assesment from pressure insole data increased with the vertical force applied to the pressure insole and with the number of pressure cells involved.https://www.mdpi.com/1424-8220/22/15/5628biomechanicsmotion analysisground reaction forcesoutside laboratory experimentsmoticon |
spellingShingle | Pauline Morin Antoine Muller Charles Pontonnier Georges Dumont Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks Sensors biomechanics motion analysis ground reaction forces outside laboratory experiments moticon |
title | Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks |
title_full | Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks |
title_fullStr | Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks |
title_full_unstemmed | Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks |
title_short | Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks |
title_sort | evaluation of the foot center of pressure estimation from pressure insoles during sidestep cuts runs and walks |
topic | biomechanics motion analysis ground reaction forces outside laboratory experiments moticon |
url | https://www.mdpi.com/1424-8220/22/15/5628 |
work_keys_str_mv | AT paulinemorin evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks AT antoinemuller evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks AT charlespontonnier evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks AT georgesdumont evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks |