Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics

In subjects with functionally bicuspid aortic valves (BAVs) with fusion between the coronary leaflets, there is a natural variation of the commissural angle. What is not fully understood is how this variation influences the hemodynamics and tissue biomechanics. These variables may influence valvar d...

Full description

Bibliographic Details
Main Authors: Elias Sundström, Justin T. Tretter
Format: Article
Language:English
Published: MDPI AG 2023-10-01
Series:Bioengineering
Subjects:
Online Access:https://www.mdpi.com/2306-5354/10/10/1219
_version_ 1797574691819356160
author Elias Sundström
Justin T. Tretter
author_facet Elias Sundström
Justin T. Tretter
author_sort Elias Sundström
collection DOAJ
description In subjects with functionally bicuspid aortic valves (BAVs) with fusion between the coronary leaflets, there is a natural variation of the commissural angle. What is not fully understood is how this variation influences the hemodynamics and tissue biomechanics. These variables may influence valvar durability and function, both in the native valve and following repair, and influence ongoing aortic dilation. A 3D aortic valvar model was reconstructed from a patient with a normal trileaflet aortic valve using cardiac magnetic resonance (CMR) imaging. Fluid–structure interaction (FSI) simulations were used to compare the effects of the varying commissural angles between the non-coronary with its adjacent coronary leaflet. The results showed that the BAV with very asymmetric commissures (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>120</mn><mo>∘</mo></msup></semantics></math></inline-formula> degree commissural angle) reduces the aortic opening area during peak systole and with a jet that impacts on the right posterior wall proximally of the ascending aorta, giving rise to elevated wall shear stress. This manifests in a shear layer with a retrograde flow and strong swirling towards the fused leaflet side. In contrast, a more symmetrical commissural angle (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>180</mn><mo>∘</mo></msup></semantics></math></inline-formula> degree commissural angle) reduces the jet impact on the posterior wall and leads to a linear decrease in stress and strain levels in the non-fused non-coronary leaflet. These findings highlight the importance of considering the commissural angle in the progression of aortic valvar stenosis, the regional distribution of stresses and strain levels experienced by the leaflets which may predispose to valvar deterioration, and progression in thoracic aortic dilation in patients with functionally bicuspid aortic valves. Understanding the hemodynamics and biomechanics of the functionally bicuspid aortic valve and its variation in structure may provide insight into predicting the risk of aortic valve dysfunction and thoracic aortic dilation, which could inform clinical decision making and potentially lead to improved aortic valvar surgical outcomes.
first_indexed 2024-03-10T21:25:54Z
format Article
id doaj.art-d83af13bc59a4a17943e3c255dd9b85f
institution Directory Open Access Journal
issn 2306-5354
language English
last_indexed 2024-03-10T21:25:54Z
publishDate 2023-10-01
publisher MDPI AG
record_format Article
series Bioengineering
spelling doaj.art-d83af13bc59a4a17943e3c255dd9b85f2023-11-19T15:42:41ZengMDPI AGBioengineering2306-53542023-10-011010121910.3390/bioengineering10101219Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue BiomechanicsElias Sundström0Justin T. Tretter1Department of Engineering Mechanics, Flow Research Center, KTH Royal Institute of Technology, Teknikringen 8, 100 44 Stockholm, SwedenCongenital Valve Procedural Planning Center, Department of Pediatric Cardiology and Division of Pediatric Cardiac Surgery, Cleveland Clinic Children’s, and The Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USAIn subjects with functionally bicuspid aortic valves (BAVs) with fusion between the coronary leaflets, there is a natural variation of the commissural angle. What is not fully understood is how this variation influences the hemodynamics and tissue biomechanics. These variables may influence valvar durability and function, both in the native valve and following repair, and influence ongoing aortic dilation. A 3D aortic valvar model was reconstructed from a patient with a normal trileaflet aortic valve using cardiac magnetic resonance (CMR) imaging. Fluid–structure interaction (FSI) simulations were used to compare the effects of the varying commissural angles between the non-coronary with its adjacent coronary leaflet. The results showed that the BAV with very asymmetric commissures (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>120</mn><mo>∘</mo></msup></semantics></math></inline-formula> degree commissural angle) reduces the aortic opening area during peak systole and with a jet that impacts on the right posterior wall proximally of the ascending aorta, giving rise to elevated wall shear stress. This manifests in a shear layer with a retrograde flow and strong swirling towards the fused leaflet side. In contrast, a more symmetrical commissural angle (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>180</mn><mo>∘</mo></msup></semantics></math></inline-formula> degree commissural angle) reduces the jet impact on the posterior wall and leads to a linear decrease in stress and strain levels in the non-fused non-coronary leaflet. These findings highlight the importance of considering the commissural angle in the progression of aortic valvar stenosis, the regional distribution of stresses and strain levels experienced by the leaflets which may predispose to valvar deterioration, and progression in thoracic aortic dilation in patients with functionally bicuspid aortic valves. Understanding the hemodynamics and biomechanics of the functionally bicuspid aortic valve and its variation in structure may provide insight into predicting the risk of aortic valve dysfunction and thoracic aortic dilation, which could inform clinical decision making and potentially lead to improved aortic valvar surgical outcomes.https://www.mdpi.com/2306-5354/10/10/1219bicuspid aortic valvecommissural anglefluid–structure interactionmagnetic resonance
spellingShingle Elias Sundström
Justin T. Tretter
Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
Bioengineering
bicuspid aortic valve
commissural angle
fluid–structure interaction
magnetic resonance
title Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
title_full Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
title_fullStr Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
title_full_unstemmed Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
title_short Impact of Variation in Commissural Angle between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics
title_sort impact of variation in commissural angle between fused leaflets in the functionally bicuspid aortic valve on hemodynamics and tissue biomechanics
topic bicuspid aortic valve
commissural angle
fluid–structure interaction
magnetic resonance
url https://www.mdpi.com/2306-5354/10/10/1219
work_keys_str_mv AT eliassundstrom impactofvariationincommissuralanglebetweenfusedleafletsinthefunctionallybicuspidaorticvalveonhemodynamicsandtissuebiomechanics
AT justinttretter impactofvariationincommissuralanglebetweenfusedleafletsinthefunctionallybicuspidaorticvalveonhemodynamicsandtissuebiomechanics