Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3

The standardization and control of «BiVac polio» (live attenuated bivalent oral polio vaccine type 1 and 3) developed by M. P. Chumakov Institute of Poliomyelitis and Viral Encephalitides of the Russian Academy of Medical Sciences, called for establishment of an industry reference standard (IRS) to...

Full description

Bibliographic Details
Main Authors: E. V. Karpova, A. D. Sangadzhieva, T. V. Mamontova, O. V. Fadeykina, R. A. Volkova, K. A. Sarkisyan, A. A. Movsesyants
Format: Article
Language:Russian
Published: Ministry of Health of the Russian Federation. Federal State Budgetary Institution «Scientific Centre for Expert Evaluation of Medicinal Products» 2018-02-01
Series:Биопрепараты: Профилактика, диагностика, лечение
Subjects:
Online Access:https://www.biopreparations.ru/jour/article/view/91
_version_ 1797244517069357056
author E. V. Karpova
A. D. Sangadzhieva
T. V. Mamontova
O. V. Fadeykina
R. A. Volkova
K. A. Sarkisyan
A. A. Movsesyants
author_facet E. V. Karpova
A. D. Sangadzhieva
T. V. Mamontova
O. V. Fadeykina
R. A. Volkova
K. A. Sarkisyan
A. A. Movsesyants
author_sort E. V. Karpova
collection DOAJ
description The standardization and control of «BiVac polio» (live attenuated bivalent oral polio vaccine type 1 and 3) developed by M. P. Chumakov Institute of Poliomyelitis and Viral Encephalitides of the Russian Academy of Medical Sciences, called for establishment of an industry reference standard (IRS) to be used in determination of infectious units for each type of the poliovirus in a vaccine dose, according to the requirements of the quality standard. The article gives an account of certification performed for the first batch of a live attenuated bivalent oral polio vaccine type 1 and 3 IRS. The following parameters were tested: Clarity, Colourity, рН, Sterility, Identification, Specific activity, Thermal stability. Identification, Specific activity and Thermal stability of the candidate reference standard were assessed in comparison with the vaccine poliovirus type 1 IRS (IRS 42-28-362-2016) and vaccine poliovirus type 3 IRS (IRS 42-28-372-2015). The IRS certified parameter was found to be: 107.38±0.38 TCID50/ml for type 1 and 106.7±0.48 TCID50/ml for type 3. The IRS was assigned with the number IRS 42-28-434-2016 and a shelf life of 1.5 years. The IRS can be used in specific activity testing of «BiVac polio» commercial batches.
first_indexed 2024-03-08T21:44:29Z
format Article
id doaj.art-d8b154d6f56c4c96a2212015e1d71b52
institution Directory Open Access Journal
issn 2221-996X
2619-1156
language Russian
last_indexed 2024-04-24T19:12:16Z
publishDate 2018-02-01
publisher Ministry of Health of the Russian Federation. Federal State Budgetary Institution «Scientific Centre for Expert Evaluation of Medicinal Products»
record_format Article
series Биопрепараты: Профилактика, диагностика, лечение
spelling doaj.art-d8b154d6f56c4c96a2212015e1d71b522024-03-26T09:10:52ZrusMinistry of Health of the Russian Federation. Federal State Budgetary Institution «Scientific Centre for Expert Evaluation of Medicinal Products»Биопрепараты: Профилактика, диагностика, лечение2221-996X2619-11562018-02-0117212212791Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3E. V. Karpova0A. D. Sangadzhieva1T. V. Mamontova2O. V. Fadeykina3R. A. Volkova4K. A. Sarkisyan5A. A. Movsesyants6Scientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsThe standardization and control of «BiVac polio» (live attenuated bivalent oral polio vaccine type 1 and 3) developed by M. P. Chumakov Institute of Poliomyelitis and Viral Encephalitides of the Russian Academy of Medical Sciences, called for establishment of an industry reference standard (IRS) to be used in determination of infectious units for each type of the poliovirus in a vaccine dose, according to the requirements of the quality standard. The article gives an account of certification performed for the first batch of a live attenuated bivalent oral polio vaccine type 1 and 3 IRS. The following parameters were tested: Clarity, Colourity, рН, Sterility, Identification, Specific activity, Thermal stability. Identification, Specific activity and Thermal stability of the candidate reference standard were assessed in comparison with the vaccine poliovirus type 1 IRS (IRS 42-28-362-2016) and vaccine poliovirus type 3 IRS (IRS 42-28-372-2015). The IRS certified parameter was found to be: 107.38±0.38 TCID50/ml for type 1 and 106.7±0.48 TCID50/ml for type 3. The IRS was assigned with the number IRS 42-28-434-2016 and a shelf life of 1.5 years. The IRS can be used in specific activity testing of «BiVac polio» commercial batches.https://www.biopreparations.ru/jour/article/view/91вакцина полиомиелитная пероральная, двухвалентная, живая аттенуированная 1, 3 типовотраслевой стандартный образецспецифическая активностьреференс-препаратыхранение вакциныкультура клетокlive attenuated bivalent oral polio vaccine type 1 and 3industry reference standardspecific activityreference medicinesvaccine storagecell culture
spellingShingle E. V. Karpova
A. D. Sangadzhieva
T. V. Mamontova
O. V. Fadeykina
R. A. Volkova
K. A. Sarkisyan
A. A. Movsesyants
Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
Биопрепараты: Профилактика, диагностика, лечение
вакцина полиомиелитная пероральная, двухвалентная, живая аттенуированная 1, 3 типов
отраслевой стандартный образец
специфическая активность
референс-препараты
хранение вакцины
культура клеток
live attenuated bivalent oral polio vaccine type 1 and 3
industry reference standard
specific activity
reference medicines
vaccine storage
cell culture
title Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
title_full Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
title_fullStr Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
title_full_unstemmed Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
title_short Certification of the industry reference standard for the specific activity of «BiVac polio» - live attenuated bivalent oral polio vaccine type 1 and 3
title_sort certification of the industry reference standard for the specific activity of bivac polio live attenuated bivalent oral polio vaccine type 1 and 3
topic вакцина полиомиелитная пероральная, двухвалентная, живая аттенуированная 1, 3 типов
отраслевой стандартный образец
специфическая активность
референс-препараты
хранение вакцины
культура клеток
live attenuated bivalent oral polio vaccine type 1 and 3
industry reference standard
specific activity
reference medicines
vaccine storage
cell culture
url https://www.biopreparations.ru/jour/article/view/91
work_keys_str_mv AT evkarpova certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT adsangadzhieva certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT tvmamontova certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT ovfadeykina certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT ravolkova certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT kasarkisyan certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3
AT aamovsesyants certificationoftheindustryreferencestandardforthespecificactivityofbivacpolioliveattenuatedbivalentoralpoliovaccinetype1and3