Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital

Background: Diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. Quality of blood glucose monitoring utilizing glucometers in Iranian hospitalized patients has not been well published in the literature. We e...

Full description

Bibliographic Details
Main Authors: Shima Aghakachoei, AmirH Zargarzadeh, Masoud Amini
Format: Article
Language:English
Published: Research Center for Rational Use of Drugs (RCRUD) 2015-10-01
Series:Journal of Pharmaceutical Care
Subjects:
Online Access:https://jpc.tums.ac.ir/index.php/jpc/article/view/38
_version_ 1811264979386499072
author Shima Aghakachoei
AmirH Zargarzadeh
Masoud Amini
author_facet Shima Aghakachoei
AmirH Zargarzadeh
Masoud Amini
author_sort Shima Aghakachoei
collection DOAJ
description Background: Diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. Quality of blood glucose monitoring utilizing glucometers in Iranian hospitalized patients has not been well published in the literature. We evaluated the accuracy and consistency of the results of two devices compared with the standard laboratory method used for measuring glucose levels in a teaching hospital. Methods: In this study 100 patients with the average age of 57.5 ±17.7 years were randomly selected from 19 wards and their blood glucose were simultaneously measured using Accu-Chek Active®(1) and Cleverchek®(2) (commonly used in the wards) and the conventional laboratory method. Calibration was performed on both devices. Results: Absolute Mean Difference of the devices 1 and 2 from the laboratory values were 24.3±2.4,and 38.5±4.5, respectively (P: 0.003). Correlation coefficient of the obtained values by glucometers1 and 2 with lab, were 0.82 and 0.52, respectively. Calibration of the devices showed that device 1 was the most consistent device with the laboratory values, and Pearson correlation coefficient between the obtained values as a result of four reiterations for each sample in each device showed that the highest coefficient belonged to the device 1 and the least belonged to the device 2 used in the Ear, Nose, and Throat Departments. Conclusion: The device 2 used in different wards of the hospital must be calibrated periodically. Furthermore, the device 1 generated closest results to the ones obtained through the laboratory.
first_indexed 2024-04-12T20:14:15Z
format Article
id doaj.art-d8c7651a38c4405c9f1da29ea747cd3f
institution Directory Open Access Journal
issn 2322-4630
2322-4509
language English
last_indexed 2024-04-12T20:14:15Z
publishDate 2015-10-01
publisher Research Center for Rational Use of Drugs (RCRUD)
record_format Article
series Journal of Pharmaceutical Care
spelling doaj.art-d8c7651a38c4405c9f1da29ea747cd3f2022-12-22T03:18:10ZengResearch Center for Rational Use of Drugs (RCRUD)Journal of Pharmaceutical Care2322-46302322-45092015-10-012138Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching HospitalShima Aghakachoei0AmirH Zargarzadeh1Masoud Amini2Pharm. D Candidate, School of Pharmacy and Pharmaceutical Sciences, Isfahan University of Medical Sciences, Isfahan, IranAssistant Professor, Department of Clinical Pharmacy and Pharmacy Practice, School of Pharmacy and Pharmaceutical Sciences, Isfahan University of Medical Sciences, Isfahan, IranProfessor, Department of Internal Medicine, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranBackground: Diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. Quality of blood glucose monitoring utilizing glucometers in Iranian hospitalized patients has not been well published in the literature. We evaluated the accuracy and consistency of the results of two devices compared with the standard laboratory method used for measuring glucose levels in a teaching hospital. Methods: In this study 100 patients with the average age of 57.5 ±17.7 years were randomly selected from 19 wards and their blood glucose were simultaneously measured using Accu-Chek Active®(1) and Cleverchek®(2) (commonly used in the wards) and the conventional laboratory method. Calibration was performed on both devices. Results: Absolute Mean Difference of the devices 1 and 2 from the laboratory values were 24.3±2.4,and 38.5±4.5, respectively (P: 0.003). Correlation coefficient of the obtained values by glucometers1 and 2 with lab, were 0.82 and 0.52, respectively. Calibration of the devices showed that device 1 was the most consistent device with the laboratory values, and Pearson correlation coefficient between the obtained values as a result of four reiterations for each sample in each device showed that the highest coefficient belonged to the device 1 and the least belonged to the device 2 used in the Ear, Nose, and Throat Departments. Conclusion: The device 2 used in different wards of the hospital must be calibrated periodically. Furthermore, the device 1 generated closest results to the ones obtained through the laboratory.https://jpc.tums.ac.ir/index.php/jpc/article/view/38Diabetes MellitusSelf Monitoring Blood GlucoseHospital
spellingShingle Shima Aghakachoei
AmirH Zargarzadeh
Masoud Amini
Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
Journal of Pharmaceutical Care
Diabetes Mellitus
Self Monitoring Blood Glucose
Hospital
title Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
title_full Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
title_fullStr Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
title_full_unstemmed Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
title_short Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital
title_sort comparison of blood glucose values using two glucose meters and standard laboratory method in hospitalized patients in a teaching hospital
topic Diabetes Mellitus
Self Monitoring Blood Glucose
Hospital
url https://jpc.tums.ac.ir/index.php/jpc/article/view/38
work_keys_str_mv AT shimaaghakachoei comparisonofbloodglucosevaluesusingtwoglucosemetersandstandardlaboratorymethodinhospitalizedpatientsinateachinghospital
AT amirhzargarzadeh comparisonofbloodglucosevaluesusingtwoglucosemetersandstandardlaboratorymethodinhospitalizedpatientsinateachinghospital
AT masoudamini comparisonofbloodglucosevaluesusingtwoglucosemetersandstandardlaboratorymethodinhospitalizedpatientsinateachinghospital