Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study

BackgroundWearable accelerometers have greatly improved measurement of physical activity, and the increasing popularity of smartwatches with inherent acceleration data collection suggest their potential use in the physical activity research domain; however, their use needs to be validated....

Full description

Bibliographic Details
Main Authors: Davoudi, Anis, Wanigatunga, Amal Asiri, Kheirkhahan, Matin, Corbett, Duane Benjamin, Mendoza, Tonatiuh, Battula, Manoj, Ranka, Sanjay, Fillingim, Roger Benton, Manini, Todd Matthew, Rashidi, Parisa
Format: Article
Language:English
Published: JMIR Publications 2019-02-01
Series:JMIR mHealth and uHealth
Online Access:http://mhealth.jmir.org/2019/2/e11270/
_version_ 1830339884894650368
author Davoudi, Anis
Wanigatunga, Amal Asiri
Kheirkhahan, Matin
Corbett, Duane Benjamin
Mendoza, Tonatiuh
Battula, Manoj
Ranka, Sanjay
Fillingim, Roger Benton
Manini, Todd Matthew
Rashidi, Parisa
author_facet Davoudi, Anis
Wanigatunga, Amal Asiri
Kheirkhahan, Matin
Corbett, Duane Benjamin
Mendoza, Tonatiuh
Battula, Manoj
Ranka, Sanjay
Fillingim, Roger Benton
Manini, Todd Matthew
Rashidi, Parisa
author_sort Davoudi, Anis
collection DOAJ
description BackgroundWearable accelerometers have greatly improved measurement of physical activity, and the increasing popularity of smartwatches with inherent acceleration data collection suggest their potential use in the physical activity research domain; however, their use needs to be validated. ObjectiveThis study aimed to assess the validity of accelerometer data collected from a Samsung Gear S smartwatch (SGS) compared with an ActiGraph GT3X+ (GT3X+) activity monitor. The study aims were to (1) assess SGS validity using a mechanical shaker; (2) assess SGS validity using a treadmill running test; and (3) compare individual activity recognition, location of major body movement detection, activity intensity detection, locomotion recognition, and metabolic equivalent scores (METs) estimation between the SGS and GT3X+. MethodsTo validate and compare the SGS accelerometer data with GT3X+ data, we collected data simultaneously from both devices during highly controlled, mechanically simulated, and less-controlled natural wear conditions. First, SGS and GT3X+ data were simultaneously collected from a mechanical shaker and an individual ambulating on a treadmill. Pearson correlation was calculated for mechanical shaker and treadmill experiments. Finally, SGS and GT3X+ data were simultaneously collected during 15 common daily activities performed by 40 participants (n=12 males, mean age 55.15 [SD 17.8] years). A total of 15 frequency- and time-domain features were extracted from SGS and GT3X+ data. We used these features for training machine learning models on 6 tasks: (1) individual activity recognition, (2) activity intensity detection, (3) locomotion recognition, (4) sedentary activity detection, (5) major body movement location detection, and (6) METs estimation. The classification models included random forest, support vector machines, neural networks, and decision trees. The results were compared between devices. We evaluated the effect of different feature extraction window lengths on model accuracy as defined by the percentage of correct classifications. In addition to these classification tasks, we also used the extracted features for METs estimation. ResultsThe results were compared between devices. Accelerometer data from SGS were highly correlated with the accelerometer data from GT3X+ for all 3 axes, with a correlation ≥.89 for both the shaker test and treadmill test and ≥.70 for all daily activities, except for computer work. Our results for the classification of activity intensity levels, locomotion, sedentary, major body movement location, and individual activity recognition showed overall accuracies of 0.87, 1.00, 0.98, 0.85, and 0.64, respectively. The results were not significantly different between the SGS and GT3X+. Random forest model was the best model for METs estimation (root mean squared error of .71 and r-squared value of .50). ConclusionsOur results suggest that a commercial brand smartwatch can be used in lieu of validated research grade activity monitors for individual activity recognition, major body movement location detection, activity intensity detection, and locomotion detection tasks.
first_indexed 2024-12-19T21:05:19Z
format Article
id doaj.art-d8f0441ac67c48f68fb68acff6b9d4b4
institution Directory Open Access Journal
issn 2291-5222
language English
last_indexed 2024-12-19T21:05:19Z
publishDate 2019-02-01
publisher JMIR Publications
record_format Article
series JMIR mHealth and uHealth
spelling doaj.art-d8f0441ac67c48f68fb68acff6b9d4b42022-12-21T20:05:40ZengJMIR PublicationsJMIR mHealth and uHealth2291-52222019-02-0172e1127010.2196/11270Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation StudyDavoudi, AnisWanigatunga, Amal AsiriKheirkhahan, MatinCorbett, Duane BenjaminMendoza, TonatiuhBattula, ManojRanka, SanjayFillingim, Roger BentonManini, Todd MatthewRashidi, ParisaBackgroundWearable accelerometers have greatly improved measurement of physical activity, and the increasing popularity of smartwatches with inherent acceleration data collection suggest their potential use in the physical activity research domain; however, their use needs to be validated. ObjectiveThis study aimed to assess the validity of accelerometer data collected from a Samsung Gear S smartwatch (SGS) compared with an ActiGraph GT3X+ (GT3X+) activity monitor. The study aims were to (1) assess SGS validity using a mechanical shaker; (2) assess SGS validity using a treadmill running test; and (3) compare individual activity recognition, location of major body movement detection, activity intensity detection, locomotion recognition, and metabolic equivalent scores (METs) estimation between the SGS and GT3X+. MethodsTo validate and compare the SGS accelerometer data with GT3X+ data, we collected data simultaneously from both devices during highly controlled, mechanically simulated, and less-controlled natural wear conditions. First, SGS and GT3X+ data were simultaneously collected from a mechanical shaker and an individual ambulating on a treadmill. Pearson correlation was calculated for mechanical shaker and treadmill experiments. Finally, SGS and GT3X+ data were simultaneously collected during 15 common daily activities performed by 40 participants (n=12 males, mean age 55.15 [SD 17.8] years). A total of 15 frequency- and time-domain features were extracted from SGS and GT3X+ data. We used these features for training machine learning models on 6 tasks: (1) individual activity recognition, (2) activity intensity detection, (3) locomotion recognition, (4) sedentary activity detection, (5) major body movement location detection, and (6) METs estimation. The classification models included random forest, support vector machines, neural networks, and decision trees. The results were compared between devices. We evaluated the effect of different feature extraction window lengths on model accuracy as defined by the percentage of correct classifications. In addition to these classification tasks, we also used the extracted features for METs estimation. ResultsThe results were compared between devices. Accelerometer data from SGS were highly correlated with the accelerometer data from GT3X+ for all 3 axes, with a correlation ≥.89 for both the shaker test and treadmill test and ≥.70 for all daily activities, except for computer work. Our results for the classification of activity intensity levels, locomotion, sedentary, major body movement location, and individual activity recognition showed overall accuracies of 0.87, 1.00, 0.98, 0.85, and 0.64, respectively. The results were not significantly different between the SGS and GT3X+. Random forest model was the best model for METs estimation (root mean squared error of .71 and r-squared value of .50). ConclusionsOur results suggest that a commercial brand smartwatch can be used in lieu of validated research grade activity monitors for individual activity recognition, major body movement location detection, activity intensity detection, and locomotion detection tasks.http://mhealth.jmir.org/2019/2/e11270/
spellingShingle Davoudi, Anis
Wanigatunga, Amal Asiri
Kheirkhahan, Matin
Corbett, Duane Benjamin
Mendoza, Tonatiuh
Battula, Manoj
Ranka, Sanjay
Fillingim, Roger Benton
Manini, Todd Matthew
Rashidi, Parisa
Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
JMIR mHealth and uHealth
title Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
title_full Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
title_fullStr Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
title_full_unstemmed Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
title_short Accuracy of Samsung Gear S Smartwatch for Activity Recognition: Validation Study
title_sort accuracy of samsung gear s smartwatch for activity recognition validation study
url http://mhealth.jmir.org/2019/2/e11270/
work_keys_str_mv AT davoudianis accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT wanigatungaamalasiri accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT kheirkhahanmatin accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT corbettduanebenjamin accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT mendozatonatiuh accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT battulamanoj accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT rankasanjay accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT fillingimrogerbenton accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT maninitoddmatthew accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy
AT rashidiparisa accuracyofsamsunggearssmartwatchforactivityrecognitionvalidationstudy