Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.

The article provides a systematic approach to quality control of measurements of total alpha-and beta-activity using a counter with a low background ALPHA / BETA COUNTING SYSTEM ALBA (mod. ALBA / LLAB) and software ALBA 2000 v.2.5.6. The purpose is to determine the compliance of these objects with t...

Full description

Bibliographic Details
Main Authors: Z. Malimon, T. Vinokurova, V. Salata, H. Kochetova, T. Prokopenko, L. Gusak
Format: Article
Language:English
Published: Stepan Gzhytskyi National University of Veterinary Medicine and Biotechnologies Lviv 2022-07-01
Series:Науковий вісник Львівського національного університету ветеринарної медицини та біотехнологій імені С.З. Ґжицького: Серія Ветеринарні науки
Subjects:
Online Access:https://nvlvet.com.ua/index.php/journal/article/view/4355
_version_ 1798042965360246784
author Z. Malimon
T. Vinokurova
V. Salata
H. Kochetova
T. Prokopenko
L. Gusak
author_facet Z. Malimon
T. Vinokurova
V. Salata
H. Kochetova
T. Prokopenko
L. Gusak
author_sort Z. Malimon
collection DOAJ
description The article provides a systematic approach to quality control of measurements of total alpha-and beta-activity using a counter with a low background ALPHA / BETA COUNTING SYSTEM ALBA (mod. ALBA / LLAB) and software ALBA 2000 v.2.5.6. The purpose is to determine the compliance of these objects with the requirements of regulatory documentation. The spectrometry method is based on the physical concentration of radionuclides from the sample volume, measuring the rate of alpha, and beta radiation of the obtained dry residue of the sample, comparing the sample count rate with calibration values of activity, and calculating the total alpha, beta activity of the sample. The primary means of testing is a counter with a low background ALPHA / BETA COUNTING SYSTEM ALBA 200, the lower limit of measurements of the alpha activity, which is 0.02 Bq/l, and beta activity of 0.1 Bq/l, the relative random uncertainty of the measurement result is 60 % with a confidence level P = 0.95. The efficiency of registration on the alpha channel of 43 %, background on the alpha channel of 0,11 imp./min, for a measurement time of 60,000 s, the efficiency of registration on the beta channel of 30 %, background on the beta channel of 1,9 imp./min, for measurement time 60000 s. As a comparison sample for calculating total alpha activity, a sample with alpha radiation, 241Am (geometry 2π), is used. To calculate the total beta activity, a sample of beta-emitter of potassium sulfate with radionuclide is used at 40K (geometry 2π). The weight of the counting sample ranges from 200 to 1000 mg. The activity values are calculated automatically, using the software ALBA 2000, v.2.5.6. Measurement of the total activity of radionuclides in counting samples using the method should be performed only in calibrated geometries. At the same time, the safety requirements, personnel qualifications, and test conditions must be met. Quality control of measurements in the alpha, beta counter ALBA-2000 v.2.5.6. It is carried out in qualitative and quantitative ways.
first_indexed 2024-04-11T22:42:52Z
format Article
id doaj.art-d93f6af8878a4dc1b54c542f5377415e
institution Directory Open Access Journal
issn 2518-7554
2518-1327
language English
last_indexed 2024-04-11T22:42:52Z
publishDate 2022-07-01
publisher Stepan Gzhytskyi National University of Veterinary Medicine and Biotechnologies Lviv
record_format Article
series Науковий вісник Львівського національного університету ветеринарної медицини та біотехнологій імені С.З. Ґжицького: Серія Ветеринарні науки
spelling doaj.art-d93f6af8878a4dc1b54c542f5377415e2022-12-22T03:58:56ZengStepan Gzhytskyi National University of Veterinary Medicine and Biotechnologies LvivНауковий вісник Львівського національного університету ветеринарної медицини та біотехнологій імені С.З. Ґжицького: Серія Ветеринарні науки2518-75542518-13272022-07-0124106182110.32718/nvlvet106034355Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.Z. Malimon0T. Vinokurova1V. Salata2H. Kochetova3T. Prokopenko4L. Gusak5State Scientific and Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, UkraineState Scientific and Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, UkraineStepan Gzhytskyi National University of Veterinary Medicine and Biotechnologies, Lviv, UkraineState Scientific and Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, UkraineState Scientific and Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, UkraineState Scientific and Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, UkraineThe article provides a systematic approach to quality control of measurements of total alpha-and beta-activity using a counter with a low background ALPHA / BETA COUNTING SYSTEM ALBA (mod. ALBA / LLAB) and software ALBA 2000 v.2.5.6. The purpose is to determine the compliance of these objects with the requirements of regulatory documentation. The spectrometry method is based on the physical concentration of radionuclides from the sample volume, measuring the rate of alpha, and beta radiation of the obtained dry residue of the sample, comparing the sample count rate with calibration values of activity, and calculating the total alpha, beta activity of the sample. The primary means of testing is a counter with a low background ALPHA / BETA COUNTING SYSTEM ALBA 200, the lower limit of measurements of the alpha activity, which is 0.02 Bq/l, and beta activity of 0.1 Bq/l, the relative random uncertainty of the measurement result is 60 % with a confidence level P = 0.95. The efficiency of registration on the alpha channel of 43 %, background on the alpha channel of 0,11 imp./min, for a measurement time of 60,000 s, the efficiency of registration on the beta channel of 30 %, background on the beta channel of 1,9 imp./min, for measurement time 60000 s. As a comparison sample for calculating total alpha activity, a sample with alpha radiation, 241Am (geometry 2π), is used. To calculate the total beta activity, a sample of beta-emitter of potassium sulfate with radionuclide is used at 40K (geometry 2π). The weight of the counting sample ranges from 200 to 1000 mg. The activity values are calculated automatically, using the software ALBA 2000, v.2.5.6. Measurement of the total activity of radionuclides in counting samples using the method should be performed only in calibrated geometries. At the same time, the safety requirements, personnel qualifications, and test conditions must be met. Quality control of measurements in the alpha, beta counter ALBA-2000 v.2.5.6. It is carried out in qualitative and quantitative ways.https://nvlvet.com.ua/index.php/journal/article/view/4355counting sample, total activity, physical concentration, efficiency of registration, control card
spellingShingle Z. Malimon
T. Vinokurova
V. Salata
H. Kochetova
T. Prokopenko
L. Gusak
Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
Науковий вісник Львівського національного університету ветеринарної медицини та біотехнологій імені С.З. Ґжицького: Серія Ветеринарні науки
counting sample, total activity, physical concentration, efficiency of registration, control card
title Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
title_full Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
title_fullStr Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
title_full_unstemmed Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
title_short Control quality measurements of alpha and beta counter with low back-ground ALBA 2000 v.2.5.6.
title_sort control quality measurements of alpha and beta counter with low back ground alba 2000 v 2 5 6
topic counting sample, total activity, physical concentration, efficiency of registration, control card
url https://nvlvet.com.ua/index.php/journal/article/view/4355
work_keys_str_mv AT zmalimon controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256
AT tvinokurova controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256
AT vsalata controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256
AT hkochetova controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256
AT tprokopenko controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256
AT lgusak controlqualitymeasurementsofalphaandbetacounterwithlowbackgroundalba2000v256