ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)

One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and result in a reduced capacity of the transformer. The declining capacity, loading on the transformer will not be maximized...

Full description

Bibliographic Details
Main Authors: Sulistiyono Sulistiyono, Haris Nur Azis
Format: Article
Language:Indonesian
Published: Universitas Mercu Buana 2016-11-01
Series:Jurnal Teknik Mesin
Online Access:http://publikasi.mercubuana.ac.id/index.php/jtm/article/view/1224
_version_ 1811268266165796864
author Sulistiyono Sulistiyono
Haris Nur Azis
author_facet Sulistiyono Sulistiyono
Haris Nur Azis
author_sort Sulistiyono Sulistiyono
collection DOAJ
description One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and result in a reduced capacity of the transformer. The declining capacity, loading on the transformer will not be maximized and increase the risk of damage. Actions taken to attempt the decrease disturbances resulting from the transformer loadings are by the transformer test and known how many percent decrease in capacity of the transformer. The data from the test is used to calculate the reduction in the capacity of the transformer. Result of the research on the transformer which is not operated yet relating to the ideal state of a transformer. As for the research on the second transformer indicates how transformer which been operating for several years has decreased the capacity of the transformer. So that the second transformer can not be loaded to the maximum.
first_indexed 2024-04-12T21:19:45Z
format Article
id doaj.art-d956591351184e2f80c43ad1493a92c9
institution Directory Open Access Journal
issn 2089-7235
2549-2888
language Indonesian
last_indexed 2024-04-12T21:19:45Z
publishDate 2016-11-01
publisher Universitas Mercu Buana
record_format Article
series Jurnal Teknik Mesin
spelling doaj.art-d956591351184e2f80c43ad1493a92c92022-12-22T03:16:21ZindUniversitas Mercu BuanaJurnal Teknik Mesin2089-72352549-28882016-11-015416717410.22441/jtm.v5i4.12241145ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)Sulistiyono Sulistiyono0Haris Nur AzisProgram Studi Teknik Elektro, Fakultas Teknik, Universitas Mercu Buana, JakartaOne cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and result in a reduced capacity of the transformer. The declining capacity, loading on the transformer will not be maximized and increase the risk of damage. Actions taken to attempt the decrease disturbances resulting from the transformer loadings are by the transformer test and known how many percent decrease in capacity of the transformer. The data from the test is used to calculate the reduction in the capacity of the transformer. Result of the research on the transformer which is not operated yet relating to the ideal state of a transformer. As for the research on the second transformer indicates how transformer which been operating for several years has decreased the capacity of the transformer. So that the second transformer can not be loaded to the maximum.http://publikasi.mercubuana.ac.id/index.php/jtm/article/view/1224
spellingShingle Sulistiyono Sulistiyono
Haris Nur Azis
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
Jurnal Teknik Mesin
title ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
title_full ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
title_fullStr ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
title_full_unstemmed ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
title_short ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO)
title_sort analisis pengaruh masa operasional terhadap penurunan kapasitas transformator distribusi di pt pln persero
url http://publikasi.mercubuana.ac.id/index.php/jtm/article/view/1224
work_keys_str_mv AT sulistiyonosulistiyono analisispengaruhmasaoperasionalterhadappenurunankapasitastransformatordistribusidiptplnpersero
AT harisnurazis analisispengaruhmasaoperasionalterhadappenurunankapasitastransformatordistribusidiptplnpersero