Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA)
Abstract Background Recently, vascular shear wave elastography (SWE) applications have gained the interest and shown potential clinical value. However, there is limited evidence about the variability in Young’s modulus (YM) estimates. The purpose of this study was to quantify sources of variability...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2022-10-01
|
Series: | The Egyptian Journal of Radiology and Nuclear Medicine |
Subjects: | |
Online Access: | https://doi.org/10.1186/s43055-022-00902-0 |
_version_ | 1811226571215732736 |
---|---|
author | Fahad F. Almutairi |
author_facet | Fahad F. Almutairi |
author_sort | Fahad F. Almutairi |
collection | DOAJ |
description | Abstract Background Recently, vascular shear wave elastography (SWE) applications have gained the interest and shown potential clinical value. However, there is limited evidence about the variability in Young’s modulus (YM) estimates. The purpose of this study was to quantify sources of variability associated with SWE measurements in common carotid artery (CCA). Results Mean YM of both anterior proximal and distal region of interest (ROIs) of the right CCA was significantly different (61 kPa vs 55.6 kPa; p < 0.001). Mean YM of anterior and posterior proximal and distal ROIs of the left side was significantly different (58.9 kPa vs 52.4 kPa; p < 0.001). Mean YM of right anterior and posterior proximal and distal ROIs was significantly different (58.3 kPa vs 51 kPa; p < 0.001). Conclusions US SWE was able to assess YM in CCAs although YM measurements were highly variable. The difference between YM between anterior and posterior walls is attributed to an artifact of the SWE technique that has not previously been reported and requires further investigation. |
first_indexed | 2024-04-12T09:27:26Z |
format | Article |
id | doaj.art-d98595b1c82d420e8b6ff9ea77f115f8 |
institution | Directory Open Access Journal |
issn | 2090-4762 |
language | English |
last_indexed | 2024-04-12T09:27:26Z |
publishDate | 2022-10-01 |
publisher | SpringerOpen |
record_format | Article |
series | The Egyptian Journal of Radiology and Nuclear Medicine |
spelling | doaj.art-d98595b1c82d420e8b6ff9ea77f115f82022-12-22T03:38:27ZengSpringerOpenThe Egyptian Journal of Radiology and Nuclear Medicine2090-47622022-10-015311610.1186/s43055-022-00902-0Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA)Fahad F. Almutairi0Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz UniversityAbstract Background Recently, vascular shear wave elastography (SWE) applications have gained the interest and shown potential clinical value. However, there is limited evidence about the variability in Young’s modulus (YM) estimates. The purpose of this study was to quantify sources of variability associated with SWE measurements in common carotid artery (CCA). Results Mean YM of both anterior proximal and distal region of interest (ROIs) of the right CCA was significantly different (61 kPa vs 55.6 kPa; p < 0.001). Mean YM of anterior and posterior proximal and distal ROIs of the left side was significantly different (58.9 kPa vs 52.4 kPa; p < 0.001). Mean YM of right anterior and posterior proximal and distal ROIs was significantly different (58.3 kPa vs 51 kPa; p < 0.001). Conclusions US SWE was able to assess YM in CCAs although YM measurements were highly variable. The difference between YM between anterior and posterior walls is attributed to an artifact of the SWE technique that has not previously been reported and requires further investigation.https://doi.org/10.1186/s43055-022-00902-0Shear wave elastographySWEArterial stiffnessVariabilityCommon carotid arteryCCA |
spellingShingle | Fahad F. Almutairi Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) The Egyptian Journal of Radiology and Nuclear Medicine Shear wave elastography SWE Arterial stiffness Variability Common carotid artery CCA |
title | Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) |
title_full | Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) |
title_fullStr | Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) |
title_full_unstemmed | Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) |
title_short | Measurement variability in two-dimensional shear wave elastography (SWE) of common carotid artery (CCA) |
title_sort | measurement variability in two dimensional shear wave elastography swe of common carotid artery cca |
topic | Shear wave elastography SWE Arterial stiffness Variability Common carotid artery CCA |
url | https://doi.org/10.1186/s43055-022-00902-0 |
work_keys_str_mv | AT fahadfalmutairi measurementvariabilityintwodimensionalshearwaveelastographysweofcommoncarotidarterycca |