Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode

This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms...

Full description

Bibliographic Details
Main Authors: Olga Domínguez-Renedo, M. Julia Arcos-Martínez, M. Jesús Gómez González
Format: Article
Language:English
Published: MDPI AG 2009-01-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/9/1/219/
_version_ 1797999090249760768
author Olga Domínguez-Renedo
M. Julia Arcos-Martínez
M. Jesús Gómez González
author_facet Olga Domínguez-Renedo
M. Julia Arcos-Martínez
M. Jesús Gómez González
author_sort Olga Domínguez-Renedo
collection DOAJ
description This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10–8 M. The linear range obtained was between 0.99 × 10–8 – 8.26 × 10–8 M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples.
first_indexed 2024-04-11T10:59:04Z
format Article
id doaj.art-d9dff1e3bb5b4dd391d07d602d19eba8
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-11T10:59:04Z
publishDate 2009-01-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-d9dff1e3bb5b4dd391d07d602d19eba82022-12-22T04:28:41ZengMDPI AGSensors1424-82202009-01-019121923110.3390/s90100219Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed ElectrodeOlga Domínguez-RenedoM. Julia Arcos-MartínezM. Jesús Gómez GonzálezThis paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10–8 M. The linear range obtained was between 0.99 × 10–8 – 8.26 × 10–8 M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples.http://www.mdpi.com/1424-8220/9/1/219/antimonyanodic stripping voltammetrymercury film electrodescreen-printed
spellingShingle Olga Domínguez-Renedo
M. Julia Arcos-Martínez
M. Jesús Gómez González
Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
Sensors
antimony
anodic stripping voltammetry
mercury film electrode
screen-printed
title Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
title_full Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
title_fullStr Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
title_full_unstemmed Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
title_short Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
title_sort determination of antimony iii in real samples by anodic stripping voltammetry using a mercury film screen printed electrode
topic antimony
anodic stripping voltammetry
mercury film electrode
screen-printed
url http://www.mdpi.com/1424-8220/9/1/219/
work_keys_str_mv AT olgadomaƒanguezrenedo determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode
AT mjuliaarcosmartaƒanez determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode
AT mjesaƒaosgaƒa3mezgonzaƒalez determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode