Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2009-01-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/9/1/219/ |
_version_ | 1797999090249760768 |
---|---|
author | Olga DomÃÂnguez-Renedo M. Julia Arcos-MartÃÂnez M. Jesús Gómez González |
author_facet | Olga DomÃÂnguez-Renedo M. Julia Arcos-MartÃÂnez M. Jesús Gómez González |
author_sort | Olga DomÃÂnguez-Renedo |
collection | DOAJ |
description | This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10–8 M. The linear range obtained was between 0.99 × 10–8 – 8.26 × 10–8 M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples. |
first_indexed | 2024-04-11T10:59:04Z |
format | Article |
id | doaj.art-d9dff1e3bb5b4dd391d07d602d19eba8 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-04-11T10:59:04Z |
publishDate | 2009-01-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-d9dff1e3bb5b4dd391d07d602d19eba82022-12-22T04:28:41ZengMDPI AGSensors1424-82202009-01-019121923110.3390/s90100219Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed ElectrodeOlga DomÃÂnguez-RenedoM. Julia Arcos-MartÃÂnezM. Jesús Gómez GonzálezThis paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10–8 M. The linear range obtained was between 0.99 × 10–8 – 8.26 × 10–8 M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples.http://www.mdpi.com/1424-8220/9/1/219/antimonyanodic stripping voltammetrymercury film electrodescreen-printed |
spellingShingle | Olga DomÃÂnguez-Renedo M. Julia Arcos-MartÃÂnez M. Jesús Gómez González Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode Sensors antimony anodic stripping voltammetry mercury film electrode screen-printed |
title | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_full | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_fullStr | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_full_unstemmed | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_short | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_sort | determination of antimony iii in real samples by anodic stripping voltammetry using a mercury film screen printed electrode |
topic | antimony anodic stripping voltammetry mercury film electrode screen-printed |
url | http://www.mdpi.com/1424-8220/9/1/219/ |
work_keys_str_mv | AT olgadomaƒanguezrenedo determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode AT mjuliaarcosmartaƒanez determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode AT mjesaƒaosgaƒa3mezgonzaƒalez determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode |