Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections

The conventional method of increasing the current carrying capacity of the submarine cable landing section increases the manufacturing cost of the submarine cable and the long-term operational reliability. This paper introduces the unequal diameter cable joint technology and checks and analyzes the...

Full description

Bibliographic Details
Main Authors: SUN Lu, LE Yanjie, RUAN Tianyu, ZHANG Lei, LIU Zongxi
Format: Article
Language:zho
Published: zhejiang electric power 2022-08-01
Series:Zhejiang dianli
Subjects:
Online Access:https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=24444a40-5f5f-46df-8af5-3a85d84277cd
_version_ 1798001846333210624
author SUN Lu
LE Yanjie
RUAN Tianyu
ZHANG Lei
LIU Zongxi
author_facet SUN Lu
LE Yanjie
RUAN Tianyu
ZHANG Lei
LIU Zongxi
author_sort SUN Lu
collection DOAJ
description The conventional method of increasing the current carrying capacity of the submarine cable landing section increases the manufacturing cost of the submarine cable and the long-term operational reliability. This paper introduces the unequal diameter cable joint technology and checks and analyzes the actual current-carrying capacity of the 220 kV submarine cable landing section and the submarine section. Also, it proposes a differentiated unequal diameter submarine cable landing section and submarine section conductor cross-section matching principle and evaluates the economic efficiency of the unequal diameter cable matching scheme. The research results show that the larger the conductor cross-section of the submarine cable, the greater the drop in current-carrying capacity during the landing section. In the unequal diameter matching method, the single-core or copper wire armored submarine cable requires a smaller conductor cross-section. The maximum transmission capacity can be obtained when the submarine cable line is all single-core copper wire armored. When it is all single-core steel wire armor, it can take account of the larger transmission capacity of the submarine cable line and the optimal unit capacity cost.
first_indexed 2024-04-11T11:42:40Z
format Article
id doaj.art-da2aa14bb87a4920b9a82128c2220547
institution Directory Open Access Journal
issn 1007-1881
language zho
last_indexed 2024-04-11T11:42:40Z
publishDate 2022-08-01
publisher zhejiang electric power
record_format Article
series Zhejiang dianli
spelling doaj.art-da2aa14bb87a4920b9a82128c22205472022-12-22T04:25:46Zzhozhejiang electric powerZhejiang dianli1007-18812022-08-01418808610.19585/j.zjdl.2022080111007-1881(2022)08-0080-07Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sectionsSUN Lu0LE Yanjie1RUAN Tianyu2ZHANG Lei3LIU Zongxi4State Grid Zhoushan Power Supply Company, Zhoushan Zhejiang 316021,ChinaState Grid Zhoushan Power Supply Company, Zhoushan Zhejiang 316021,ChinaState Grid Zhoushan Power Supply Company, Zhoushan Zhejiang 316021,ChinaState Grid Zhoushan Power Supply Company, Zhoushan Zhejiang 316021,ChinaChina Electric Power Research Institute Co., Ltd., Wuhan 430074, ChinaThe conventional method of increasing the current carrying capacity of the submarine cable landing section increases the manufacturing cost of the submarine cable and the long-term operational reliability. This paper introduces the unequal diameter cable joint technology and checks and analyzes the actual current-carrying capacity of the 220 kV submarine cable landing section and the submarine section. Also, it proposes a differentiated unequal diameter submarine cable landing section and submarine section conductor cross-section matching principle and evaluates the economic efficiency of the unequal diameter cable matching scheme. The research results show that the larger the conductor cross-section of the submarine cable, the greater the drop in current-carrying capacity during the landing section. In the unequal diameter matching method, the single-core or copper wire armored submarine cable requires a smaller conductor cross-section. The maximum transmission capacity can be obtained when the submarine cable line is all single-core copper wire armored. When it is all single-core steel wire armor, it can take account of the larger transmission capacity of the submarine cable line and the optimal unit capacity cost.https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=24444a40-5f5f-46df-8af5-3a85d84277cdsubmarine cableunequal diametercurrent carrying capacitycross-section matchingeconomic efficiency
spellingShingle SUN Lu
LE Yanjie
RUAN Tianyu
ZHANG Lei
LIU Zongxi
Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
Zhejiang dianli
submarine cable
unequal diameter
current carrying capacity
cross-section matching
economic efficiency
title Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
title_full Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
title_fullStr Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
title_full_unstemmed Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
title_short Research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
title_sort research on improvement of current carrying capacity of submarine cable based on unequal diameter matching of land and sea sections
topic submarine cable
unequal diameter
current carrying capacity
cross-section matching
economic efficiency
url https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=24444a40-5f5f-46df-8af5-3a85d84277cd
work_keys_str_mv AT sunlu researchonimprovementofcurrentcarryingcapacityofsubmarinecablebasedonunequaldiametermatchingoflandandseasections
AT leyanjie researchonimprovementofcurrentcarryingcapacityofsubmarinecablebasedonunequaldiametermatchingoflandandseasections
AT ruantianyu researchonimprovementofcurrentcarryingcapacityofsubmarinecablebasedonunequaldiametermatchingoflandandseasections
AT zhanglei researchonimprovementofcurrentcarryingcapacityofsubmarinecablebasedonunequaldiametermatchingoflandandseasections
AT liuzongxi researchonimprovementofcurrentcarryingcapacityofsubmarinecablebasedonunequaldiametermatchingoflandandseasections