Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures

Objective: AO (Arbeitsgemeinschaft für Osteosynthesefragen) type C distal humerus fractures are difficult fractures to reduce and fix due to the difficulty of the elbow anatomy and small size of the broken bone parts. We hypothesize that although parallel plating technique is biomechanically superio...

Full description

Bibliographic Details
Main Authors: Fatih Arslanoğlu, Çağrı Özcan, Kahraman Öztürk, Mehmet Baydar
Format: Article
Language:English
Published: Sakarya University 2022-03-01
Series:Sakarya Tıp Dergisi
Subjects:
Online Access:https://dergipark.org.tr/tr/download/article-file/2045325
_version_ 1797350367096209408
author Fatih Arslanoğlu
Çağrı Özcan
Kahraman Öztürk
Mehmet Baydar
author_facet Fatih Arslanoğlu
Çağrı Özcan
Kahraman Öztürk
Mehmet Baydar
author_sort Fatih Arslanoğlu
collection DOAJ
description Objective: AO (Arbeitsgemeinschaft für Osteosynthesefragen) type C distal humerus fractures are difficult fractures to reduce and fix due to the difficulty of the elbow anatomy and small size of the broken bone parts. We hypothesize that although parallel plating technique is biomechanically superior for humerus distal fracture, orthogonal plating technique in clinical conditions is as reliable and effective as a method of parallel plating for Type C humerus fractures. Materials and Methods: Between 2012 and 2018, 36 patients who underwent operations for AO type C distal humerus fractures and met the inclusion criteria were evaluated retrospectively. Parallel plating was performed in 20 patients and orthogonal plating (medial and posterolateral plating) in 16 patients. All patients were fixed with LC-DCP plates. Quick DASH, Mayo elbow, and VAS scores; grip strength; elbow ROM (Range of Motion); extension loss; and evaluations complications at the last visit. Results: There was no statistically significant difference between the groups in terms of the Quick DASH, Mayo elbow, or VAS scores, grip strength, elbow ROM, extension loss, union time, postoperative heterotrophic ossification, elbow and olecranon nonunion, post-op neuropraxia, or other complications (P > 0.05). There was a statistically significant difference between the two groups regarding ulnar nerve transposition (P
first_indexed 2024-03-08T12:44:48Z
format Article
id doaj.art-da65369c4229417ab5cdd1677579606e
institution Directory Open Access Journal
issn 2146-409X
language English
last_indexed 2024-03-08T12:44:48Z
publishDate 2022-03-01
publisher Sakarya University
record_format Article
series Sakarya Tıp Dergisi
spelling doaj.art-da65369c4229417ab5cdd1677579606e2024-01-21T07:40:11ZengSakarya UniversitySakarya Tıp Dergisi2146-409X2022-03-01121637010.31832/smj.101449128Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus FracturesFatih Arslanoğlu0Çağrı Özcan1Kahraman Öztürk2Mehmet Baydar3Medistanbul HospitalUniversity of Health Sciences Turkey, Umraniye Teaching and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, TurkeyUniversity of Health Sciences Turkey, M.S. Baltalimanı Bone Diseases Teaching and Research Hospital, Hand Surgery ClinicUniversity of Health Sciences Turkey, M.S. Baltalimanı Bone Diseases Teaching and Research Hospital, Hand Surgery ClinicObjective: AO (Arbeitsgemeinschaft für Osteosynthesefragen) type C distal humerus fractures are difficult fractures to reduce and fix due to the difficulty of the elbow anatomy and small size of the broken bone parts. We hypothesize that although parallel plating technique is biomechanically superior for humerus distal fracture, orthogonal plating technique in clinical conditions is as reliable and effective as a method of parallel plating for Type C humerus fractures. Materials and Methods: Between 2012 and 2018, 36 patients who underwent operations for AO type C distal humerus fractures and met the inclusion criteria were evaluated retrospectively. Parallel plating was performed in 20 patients and orthogonal plating (medial and posterolateral plating) in 16 patients. All patients were fixed with LC-DCP plates. Quick DASH, Mayo elbow, and VAS scores; grip strength; elbow ROM (Range of Motion); extension loss; and evaluations complications at the last visit. Results: There was no statistically significant difference between the groups in terms of the Quick DASH, Mayo elbow, or VAS scores, grip strength, elbow ROM, extension loss, union time, postoperative heterotrophic ossification, elbow and olecranon nonunion, post-op neuropraxia, or other complications (P > 0.05). There was a statistically significant difference between the two groups regarding ulnar nerve transposition (Phttps://dergipark.org.tr/tr/download/article-file/2045325humerus distal kırıklarıparalel plaklamaortogonal plaklamaeklem içi kırıklarhumerus distal fracturesparallel platingorthogonal platingintraarticular fractures
spellingShingle Fatih Arslanoğlu
Çağrı Özcan
Kahraman Öztürk
Mehmet Baydar
Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
Sakarya Tıp Dergisi
humerus distal kırıkları
paralel plaklama
ortogonal plaklama
eklem içi kırıklar
humerus distal fractures
parallel plating
orthogonal plating
intraarticular fractures
title Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
title_full Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
title_fullStr Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
title_full_unstemmed Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
title_short Comparison of Clinical and Radiological Results of Orthogonal and Parallel LC-DCP Plating in AO Type C Distal Humerus Fractures
title_sort comparison of clinical and radiological results of orthogonal and parallel lc dcp plating in ao type c distal humerus fractures
topic humerus distal kırıkları
paralel plaklama
ortogonal plaklama
eklem içi kırıklar
humerus distal fractures
parallel plating
orthogonal plating
intraarticular fractures
url https://dergipark.org.tr/tr/download/article-file/2045325
work_keys_str_mv AT fatiharslanoglu comparisonofclinicalandradiologicalresultsoforthogonalandparallellcdcpplatinginaotypecdistalhumerusfractures
AT cagrıozcan comparisonofclinicalandradiologicalresultsoforthogonalandparallellcdcpplatinginaotypecdistalhumerusfractures
AT kahramanozturk comparisonofclinicalandradiologicalresultsoforthogonalandparallellcdcpplatinginaotypecdistalhumerusfractures
AT mehmetbaydar comparisonofclinicalandradiologicalresultsoforthogonalandparallellcdcpplatinginaotypecdistalhumerusfractures