Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity
Takagi-Sugeno (T-S) fuzzy coronary artery system. We use the T-S fuzzy model to represent the coronary artery system, because the coronary artery system has complicated nonlinear characteristic in reality. Based on the new model, a fuzzy parametric adaptive output feedback controller is designed to...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2018-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8165968/ |
_version_ | 1818911740699607040 |
---|---|
author | Zhanshan Zhao Haoliang Cui Jing Zhang Jie Sun |
author_facet | Zhanshan Zhao Haoliang Cui Jing Zhang Jie Sun |
author_sort | Zhanshan Zhao |
collection | DOAJ |
description | Takagi-Sugeno (T-S) fuzzy coronary artery system. We use the T-S fuzzy model to represent the coronary artery system, because the coronary artery system has complicated nonlinear characteristic in reality. Based on the new model, a fuzzy parametric adaptive output feedback controller is designed to achieve the H<sub>∞</sub> synchronization of coronary artery system with input nonlinearity and parameter perturbations. Some simulation results are given to illustrate the effectiveness of our control strategy. |
first_indexed | 2024-12-19T23:03:30Z |
format | Article |
id | doaj.art-db3463bb83d34107981b3f446858f47a |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-12-19T23:03:30Z |
publishDate | 2018-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-db3463bb83d34107981b3f446858f47a2022-12-21T20:02:27ZengIEEEIEEE Access2169-35362018-01-0167082708710.1109/ACCESS.2017.27791188165968Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input NonlinearityZhanshan Zhao0https://orcid.org/0000-0002-2177-3980Haoliang Cui1Jing Zhang2Jie Sun3School of Computer Science and Software Engineering, Tianjin Polytechnic University, Tianjin, ChinaSchool of Computer Science and Software Engineering, Tianjin Polytechnic University, Tianjin, ChinaSchool of Textiles, Tianjin Polytechnic University, Tianjin, ChinaSchool of Computer Science and Software Engineering, Tianjin Polytechnic University, Tianjin, ChinaTakagi-Sugeno (T-S) fuzzy coronary artery system. We use the T-S fuzzy model to represent the coronary artery system, because the coronary artery system has complicated nonlinear characteristic in reality. Based on the new model, a fuzzy parametric adaptive output feedback controller is designed to achieve the H<sub>∞</sub> synchronization of coronary artery system with input nonlinearity and parameter perturbations. Some simulation results are given to illustrate the effectiveness of our control strategy.https://ieeexplore.ieee.org/document/8165968/Coronary artery systemadaptive controlfuzzy modelinput nonlinear<italic xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">H</italic>∞ synchronization |
spellingShingle | Zhanshan Zhao Haoliang Cui Jing Zhang Jie Sun Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity IEEE Access Coronary artery system adaptive control fuzzy model input nonlinear <italic xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">H</italic>∞ synchronization |
title | Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity |
title_full | Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity |
title_fullStr | Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity |
title_full_unstemmed | Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity |
title_short | Adaptive Fuzzy Control for Synchronization of Coronary Artery System With Input Nonlinearity |
title_sort | adaptive fuzzy control for synchronization of coronary artery system with input nonlinearity |
topic | Coronary artery system adaptive control fuzzy model input nonlinear <italic xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">H</italic>∞ synchronization |
url | https://ieeexplore.ieee.org/document/8165968/ |
work_keys_str_mv | AT zhanshanzhao adaptivefuzzycontrolforsynchronizationofcoronaryarterysystemwithinputnonlinearity AT haoliangcui adaptivefuzzycontrolforsynchronizationofcoronaryarterysystemwithinputnonlinearity AT jingzhang adaptivefuzzycontrolforsynchronizationofcoronaryarterysystemwithinputnonlinearity AT jiesun adaptivefuzzycontrolforsynchronizationofcoronaryarterysystemwithinputnonlinearity |