Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons

Abstract Background Screws are the most frequently inserted orthopaedic implants. Biomechanical, laboratory-based studies are used to provide a controlled environment to investigate revolutionary and evolutionary improvements in orthopaedic techniques. Predominantly, biomechanical trained, non-surgi...

Full description

Bibliographic Details
Main Authors: James W. A. Fletcher, Verena Neumann, Lisa Wenzel, Boyko Gueorguiev, R. Geoff Richards, Harinderjit S. Gill, Michael R. Whitehouse, Ezio Preatoni
Format: Article
Language:English
Published: BMC 2021-10-01
Series:Journal of Orthopaedic Surgery and Research
Subjects:
Online Access:https://doi.org/10.1186/s13018-021-02800-z
_version_ 1798043395597271040
author James W. A. Fletcher
Verena Neumann
Lisa Wenzel
Boyko Gueorguiev
R. Geoff Richards
Harinderjit S. Gill
Michael R. Whitehouse
Ezio Preatoni
author_facet James W. A. Fletcher
Verena Neumann
Lisa Wenzel
Boyko Gueorguiev
R. Geoff Richards
Harinderjit S. Gill
Michael R. Whitehouse
Ezio Preatoni
author_sort James W. A. Fletcher
collection DOAJ
description Abstract Background Screws are the most frequently inserted orthopaedic implants. Biomechanical, laboratory-based studies are used to provide a controlled environment to investigate revolutionary and evolutionary improvements in orthopaedic techniques. Predominantly, biomechanical trained, non-surgically practicing researchers perform these studies, whilst it will be orthopaedic surgeons who will put these procedures into practice on patients. Limited data exist on the comparative performance of surgically and non-surgically trained biomechanical researchers when inserting screws. Furthermore, any variation in performance by surgeons and/or biomechanical researchers may create an underappreciated confounder to biomechanical research findings. This study aimed to identify the differences between surgically and non-surgically trained biomechanical researchers’ achieved screw tightness and stripping rates with different fixation methods. Methods Ten orthopaedic surgeons and 10 researchers inserted 60 cortical screws each into artificial bone, for three different screw diameters (2.7, 3.5 and 4.5 mm), with 50% of screws inserted through plates and 50% through washers. Screw tightness, screw hole stripping rates and confidence in screw purchase were recorded. Three members of each group also inserted 30 screws using an augmented screwdriver, which indicated when optimum tightness was achieved. Results Unstripped screw tightness for orthopaedic surgeons and researchers was 82% (n = 928, 95% CI 81–83) and 76% (n = 1470, 95% CI 75–76) respectively (p < 0.001); surgeons stripped 48% (872/1800) of inserted screws and researchers 18% (330/1800). Using washers was associated with increased tightness [80% (95% CI 80–81), n = 1196] compared to screws inserted through plates [76% (95% CI 75–77), n = 1204] (p < 0.001). Researchers were more accurate in their overall assessment of good screw insertion (86% vs. 62%). No learning effect occurred when comparing screw tightness for the first 10 insertions against the last 10 insertions for any condition (p = 0.058–0.821). Augmented screwdrivers, indicating optimum tightness, reduced stripping rates from 34 to 21% (p < 0.001). Experience was not associated with improved performance in screw tightness or stripping rates for either group (p = 0.385–0.965). Conclusions Surgeons and researchers showed different screw tightness under the same in vitro conditions, with greater rates of screw hole stripping by surgeons. This may have important implications for the reproducibility and transferability of research findings from different settings depending on who undertakes the experiments.
first_indexed 2024-04-11T22:48:28Z
format Article
id doaj.art-db412a3d993046c98c2a16e0af3ae050
institution Directory Open Access Journal
issn 1749-799X
language English
last_indexed 2024-04-11T22:48:28Z
publishDate 2021-10-01
publisher BMC
record_format Article
series Journal of Orthopaedic Surgery and Research
spelling doaj.art-db412a3d993046c98c2a16e0af3ae0502022-12-22T03:58:41ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2021-10-011611910.1186/s13018-021-02800-zScrew tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeonsJames W. A. Fletcher0Verena Neumann1Lisa Wenzel2Boyko Gueorguiev3R. Geoff Richards4Harinderjit S. Gill5Michael R. Whitehouse6Ezio Preatoni7Applied Biomechanics Suite, Department for Health, University of BathAO Research Institute DavosAO Research Institute DavosAO Research Institute DavosAO Research Institute DavosDepartment of Mechanical Engineering, University of BathMusculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, Southmead HospitalApplied Biomechanics Suite, Department for Health, University of BathAbstract Background Screws are the most frequently inserted orthopaedic implants. Biomechanical, laboratory-based studies are used to provide a controlled environment to investigate revolutionary and evolutionary improvements in orthopaedic techniques. Predominantly, biomechanical trained, non-surgically practicing researchers perform these studies, whilst it will be orthopaedic surgeons who will put these procedures into practice on patients. Limited data exist on the comparative performance of surgically and non-surgically trained biomechanical researchers when inserting screws. Furthermore, any variation in performance by surgeons and/or biomechanical researchers may create an underappreciated confounder to biomechanical research findings. This study aimed to identify the differences between surgically and non-surgically trained biomechanical researchers’ achieved screw tightness and stripping rates with different fixation methods. Methods Ten orthopaedic surgeons and 10 researchers inserted 60 cortical screws each into artificial bone, for three different screw diameters (2.7, 3.5 and 4.5 mm), with 50% of screws inserted through plates and 50% through washers. Screw tightness, screw hole stripping rates and confidence in screw purchase were recorded. Three members of each group also inserted 30 screws using an augmented screwdriver, which indicated when optimum tightness was achieved. Results Unstripped screw tightness for orthopaedic surgeons and researchers was 82% (n = 928, 95% CI 81–83) and 76% (n = 1470, 95% CI 75–76) respectively (p < 0.001); surgeons stripped 48% (872/1800) of inserted screws and researchers 18% (330/1800). Using washers was associated with increased tightness [80% (95% CI 80–81), n = 1196] compared to screws inserted through plates [76% (95% CI 75–77), n = 1204] (p < 0.001). Researchers were more accurate in their overall assessment of good screw insertion (86% vs. 62%). No learning effect occurred when comparing screw tightness for the first 10 insertions against the last 10 insertions for any condition (p = 0.058–0.821). Augmented screwdrivers, indicating optimum tightness, reduced stripping rates from 34 to 21% (p < 0.001). Experience was not associated with improved performance in screw tightness or stripping rates for either group (p = 0.385–0.965). Conclusions Surgeons and researchers showed different screw tightness under the same in vitro conditions, with greater rates of screw hole stripping by surgeons. This may have important implications for the reproducibility and transferability of research findings from different settings depending on who undertakes the experiments.https://doi.org/10.1186/s13018-021-02800-zResearcherScrewStripping rateSurgeonTightnessTorque
spellingShingle James W. A. Fletcher
Verena Neumann
Lisa Wenzel
Boyko Gueorguiev
R. Geoff Richards
Harinderjit S. Gill
Michael R. Whitehouse
Ezio Preatoni
Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
Journal of Orthopaedic Surgery and Research
Researcher
Screw
Stripping rate
Surgeon
Tightness
Torque
title Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
title_full Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
title_fullStr Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
title_full_unstemmed Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
title_short Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
title_sort screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons
topic Researcher
Screw
Stripping rate
Surgeon
Tightness
Torque
url https://doi.org/10.1186/s13018-021-02800-z
work_keys_str_mv AT jameswafletcher screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT verenaneumann screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT lisawenzel screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT boykogueorguiev screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT rgeoffrichards screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT harinderjitsgill screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT michaelrwhitehouse screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons
AT eziopreatoni screwtightnessandstrippingratesvarybetweenbiomechanicalresearchersandpracticingorthopaedicsurgeons