The correlation between optical coherence tomography retinal shape irregularity and axial length.

PURPOSE:To describe the retinal contour in optical coherence tomography (OCT) images, and report the relationship between retinal contour and axial length. METHODS:Retinal contour was defined by the path of the retinal pigment epithelial (RPE) line in macular and extra-macular OCTs of 70 eyes of 70...

Full description

Bibliographic Details
Main Authors: Stewart Lake, Murk Bottema, Keryn Williams, Karen Reynolds
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0227207
_version_ 1819022620760211456
author Stewart Lake
Murk Bottema
Keryn Williams
Karen Reynolds
author_facet Stewart Lake
Murk Bottema
Keryn Williams
Karen Reynolds
author_sort Stewart Lake
collection DOAJ
description PURPOSE:To describe the retinal contour in optical coherence tomography (OCT) images, and report the relationship between retinal contour and axial length. METHODS:Retinal contour was defined by the path of the retinal pigment epithelial (RPE) line in macular and extra-macular OCTs of 70 eyes of 70 participants recruited from ophthalmology clinics in South Australia. The shape of this contour was described by the best-fit curvature (K), and Fourier analysis of the difference between K and the RPE. The Fourier transformation was summarised by total difference (sumdiff), maximum single frequency difference (MaxE), and root mean square difference (rmse) between each B scan residual and the average normal. All-of-eye and regional median and interquartile range (IQR) shape features were correlated to axial length. RESULTS:Retinal shape irregularity measured by Fourier transformation correlated with axial length: all-of-eye median and IQR sumdiff (ρ = 0.66 and ρ = 0.60 respectively), median and IQR rmse (ρ = 0.67 and ρ = 0.48), median MaxE (ρ = 0.61), and IQR K (ρ = 0.61) all correlated with axial length. Correlation with axial length was also seen in these parameters for 11 of 17 regions. Retinal irregularity was greatest at the macula and in inferior regions. CONCLUSION:Retinal OCT shape becomes increasingly irregular as axial length increases. The range of curvature correlates with axial length, while median curvature does not.
first_indexed 2024-12-21T04:25:54Z
format Article
id doaj.art-db5830ae825f494195238eade57056bb
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-21T04:25:54Z
publishDate 2019-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-db5830ae825f494195238eade57056bb2022-12-21T19:16:03ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011412e022720710.1371/journal.pone.0227207The correlation between optical coherence tomography retinal shape irregularity and axial length.Stewart LakeMurk BottemaKeryn WilliamsKaren ReynoldsPURPOSE:To describe the retinal contour in optical coherence tomography (OCT) images, and report the relationship between retinal contour and axial length. METHODS:Retinal contour was defined by the path of the retinal pigment epithelial (RPE) line in macular and extra-macular OCTs of 70 eyes of 70 participants recruited from ophthalmology clinics in South Australia. The shape of this contour was described by the best-fit curvature (K), and Fourier analysis of the difference between K and the RPE. The Fourier transformation was summarised by total difference (sumdiff), maximum single frequency difference (MaxE), and root mean square difference (rmse) between each B scan residual and the average normal. All-of-eye and regional median and interquartile range (IQR) shape features were correlated to axial length. RESULTS:Retinal shape irregularity measured by Fourier transformation correlated with axial length: all-of-eye median and IQR sumdiff (ρ = 0.66 and ρ = 0.60 respectively), median and IQR rmse (ρ = 0.67 and ρ = 0.48), median MaxE (ρ = 0.61), and IQR K (ρ = 0.61) all correlated with axial length. Correlation with axial length was also seen in these parameters for 11 of 17 regions. Retinal irregularity was greatest at the macula and in inferior regions. CONCLUSION:Retinal OCT shape becomes increasingly irregular as axial length increases. The range of curvature correlates with axial length, while median curvature does not.https://doi.org/10.1371/journal.pone.0227207
spellingShingle Stewart Lake
Murk Bottema
Keryn Williams
Karen Reynolds
The correlation between optical coherence tomography retinal shape irregularity and axial length.
PLoS ONE
title The correlation between optical coherence tomography retinal shape irregularity and axial length.
title_full The correlation between optical coherence tomography retinal shape irregularity and axial length.
title_fullStr The correlation between optical coherence tomography retinal shape irregularity and axial length.
title_full_unstemmed The correlation between optical coherence tomography retinal shape irregularity and axial length.
title_short The correlation between optical coherence tomography retinal shape irregularity and axial length.
title_sort correlation between optical coherence tomography retinal shape irregularity and axial length
url https://doi.org/10.1371/journal.pone.0227207
work_keys_str_mv AT stewartlake thecorrelationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT murkbottema thecorrelationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT kerynwilliams thecorrelationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT karenreynolds thecorrelationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT stewartlake correlationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT murkbottema correlationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT kerynwilliams correlationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength
AT karenreynolds correlationbetweenopticalcoherencetomographyretinalshapeirregularityandaxiallength