Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography
This study sought to evaluate a novel approach for automatic coregistration of optical coherence tomography (OCT) and coronary angiography. Lumen diameters and side branches from both coronary angiography and OCT were used to create 2 feature sets. Subsequently, a 2-step coregistration approach was...
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-09-01
|
Series: | JACC: Asia |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2772374721000715 |
_version_ | 1818733679360344064 |
---|---|
author | Hui Qin, MSc Chunming Li, BSc Yingguang Li, PhD Jiayue Huang, MSc Fan Yang, BSc Takashi Kubo, MD, PhD Takashi Akasaka, MD, PhD Changyan Xiao, PhD Juan Luis Gutiérrez-Chico, MD, PhD Shengxian Tu, PhD |
author_facet | Hui Qin, MSc Chunming Li, BSc Yingguang Li, PhD Jiayue Huang, MSc Fan Yang, BSc Takashi Kubo, MD, PhD Takashi Akasaka, MD, PhD Changyan Xiao, PhD Juan Luis Gutiérrez-Chico, MD, PhD Shengxian Tu, PhD |
author_sort | Hui Qin, MSc |
collection | DOAJ |
description | This study sought to evaluate a novel approach for automatic coregistration of optical coherence tomography (OCT) and coronary angiography. Lumen diameters and side branches from both coronary angiography and OCT were used to create 2 feature sets. Subsequently, a 2-step coregistration approach was performed on the feature sets for matching of each OCT cross section on the angiographic centerline. For validation, all side branches with ≥1.0 mm diameter were identified and used as paired fiduciary landmarks. Geographical error was defined as the distance between the automatically coregistered and the true-paired landmarks. Altogether 212 vessels from 181 patients were analyzed. Mismatch of coronary angiography and OCT occurred in 64 of 1,530 reference landmarks. Median geographical error was 0.32 (interquartile range: 0.00-0.56) mm. The mean time for coregistration was 20.69 ± 1.07 seconds. In conclusion, fast and automatic coregistration of OCT and angiography using a single standard angiographic loop is feasible and accurate. |
first_indexed | 2024-12-17T23:53:18Z |
format | Article |
id | doaj.art-db820a6750a44356814fd08dd58b5ff5 |
institution | Directory Open Access Journal |
issn | 2772-3747 |
language | English |
last_indexed | 2024-12-17T23:53:18Z |
publishDate | 2021-09-01 |
publisher | Elsevier |
record_format | Article |
series | JACC: Asia |
spelling | doaj.art-db820a6750a44356814fd08dd58b5ff52022-12-21T21:28:09ZengElsevierJACC: Asia2772-37472021-09-0112274278Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence TomographyHui Qin, MSc0Chunming Li, BSc1Yingguang Li, PhD2Jiayue Huang, MSc3Fan Yang, BSc4Takashi Kubo, MD, PhD5Takashi Akasaka, MD, PhD6Changyan Xiao, PhD7Juan Luis Gutiérrez-Chico, MD, PhD8Shengxian Tu, PhD9College of Electrical and Information Engineering, Hunan University, Changsha, China; Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaKunshan Industrial Technology Research Institute Co Ltd, Kunshan, ChinaBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaDepartment of Cardiovascular Medicine, Wakayama Medical University, Wakayama, JapanDepartment of Cardiovascular Medicine, Wakayama Medical University, Wakayama, JapanCollege of Electrical and Information Engineering, Hunan University, Changsha, ChinaCardiology Department, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, ChinaBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Address for correspondence: Dr Shengxian Tu, Room123, Med-X Research Institute, Shanghai Jiao Tong University, No. 1954, Hua Shan Road, Xuhui District, Shanghai 200030, China.This study sought to evaluate a novel approach for automatic coregistration of optical coherence tomography (OCT) and coronary angiography. Lumen diameters and side branches from both coronary angiography and OCT were used to create 2 feature sets. Subsequently, a 2-step coregistration approach was performed on the feature sets for matching of each OCT cross section on the angiographic centerline. For validation, all side branches with ≥1.0 mm diameter were identified and used as paired fiduciary landmarks. Geographical error was defined as the distance between the automatically coregistered and the true-paired landmarks. Altogether 212 vessels from 181 patients were analyzed. Mismatch of coronary angiography and OCT occurred in 64 of 1,530 reference landmarks. Median geographical error was 0.32 (interquartile range: 0.00-0.56) mm. The mean time for coregistration was 20.69 ± 1.07 seconds. In conclusion, fast and automatic coregistration of OCT and angiography using a single standard angiographic loop is feasible and accurate.http://www.sciencedirect.com/science/article/pii/S2772374721000715angiographyimage registrationoptical coherence tomographypercutaneous coronary intervention |
spellingShingle | Hui Qin, MSc Chunming Li, BSc Yingguang Li, PhD Jiayue Huang, MSc Fan Yang, BSc Takashi Kubo, MD, PhD Takashi Akasaka, MD, PhD Changyan Xiao, PhD Juan Luis Gutiérrez-Chico, MD, PhD Shengxian Tu, PhD Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography JACC: Asia angiography image registration optical coherence tomography percutaneous coronary intervention |
title | Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography |
title_full | Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography |
title_fullStr | Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography |
title_full_unstemmed | Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography |
title_short | Automatic Coregistration Between Coronary Angiography and Intravascular Optical Coherence Tomography |
title_sort | automatic coregistration between coronary angiography and intravascular optical coherence tomography |
topic | angiography image registration optical coherence tomography percutaneous coronary intervention |
url | http://www.sciencedirect.com/science/article/pii/S2772374721000715 |
work_keys_str_mv | AT huiqinmsc automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT chunminglibsc automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT yingguangliphd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT jiayuehuangmsc automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT fanyangbsc automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT takashikubomdphd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT takashiakasakamdphd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT changyanxiaophd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT juanluisgutierrezchicomdphd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography AT shengxiantuphd automaticcoregistrationbetweencoronaryangiographyandintravascularopticalcoherencetomography |