WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE

The article presents the results of preliminary research in the wideband transformer development for matching low-ohms loads in the very high frequency band with the use of a coupled transmission lines. The transmission line was produced with the using of a polyimide in the form of flexible printed...

Full description

Bibliographic Details
Main Authors: N. M. Naumovich, A. P. Joubko, M. V. Davydov, O. S. Maltsev
Format: Article
Language:Russian
Published: Educational institution «Belarusian State University of Informatics and Radioelectronics» 2019-12-01
Series:Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
Subjects:
Online Access:https://doklady.bsuir.by/jour/article/view/2421
_version_ 1797880974058455040
author N. M. Naumovich
A. P. Joubko
M. V. Davydov
O. S. Maltsev
author_facet N. M. Naumovich
A. P. Joubko
M. V. Davydov
O. S. Maltsev
author_sort N. M. Naumovich
collection DOAJ
description The article presents the results of preliminary research in the wideband transformer development for matching low-ohms loads in the very high frequency band with the use of a coupled transmission lines. The transmission line was produced with the using of a polyimide in the form of flexible printed circuit board. This way may be useful for wideband matching different cascades with custom values of input and output impedance in the wide band of frequencies and powers with use of a defining impedance capability with a load character in mind. On the first stage, the computer simulation of transformer with a transformer ratio 4:1 in the band (40–240 MHz) was completed for limiting values of input and output resistances – 50 and 12,5 Ohms respectively. Results of simulation give us the data about constructive parameters of the transmission line. The measurement technique for insertion loss was worked out. The reason of that is an impossibility of appliance standard methods with using a network vector analyzer. The prototyping was done and values of the standing wave ratio and inserting losses were obtained for different levels of the input power. According to received data, it can be affirmed, that the manufactured transformer provides the standing wave ratio better (lower) that two. Inserting losses vary from 0,02 to 1,54 dB depending from a input power level (1– 1000 mW). The obtained results afford ground for working continuation in this field – a development of wideband transformers for matching of low-ohms loads.
first_indexed 2024-04-10T03:12:47Z
format Article
id doaj.art-db859839db53482496942504b43da1e5
institution Directory Open Access Journal
issn 1729-7648
language Russian
last_indexed 2024-04-10T03:12:47Z
publishDate 2019-12-01
publisher Educational institution «Belarusian State University of Informatics and Radioelectronics»
record_format Article
series Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
spelling doaj.art-db859839db53482496942504b43da1e52023-03-13T07:33:20ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482019-12-0107-8434910.35596/1729-7648-2019-126-8-43-491471WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGEN. M. Naumovich0A. P. Joubko1M. V. Davydov2O. S. Maltsev3Belarusian State University of Informatics and RadioelectronicsBelarusian State University of Informatics and RadioelectronicsBelarusian State University of Informatics and RadioelectronicsBelarusian State University of Informatics and RadioelectronicsThe article presents the results of preliminary research in the wideband transformer development for matching low-ohms loads in the very high frequency band with the use of a coupled transmission lines. The transmission line was produced with the using of a polyimide in the form of flexible printed circuit board. This way may be useful for wideband matching different cascades with custom values of input and output impedance in the wide band of frequencies and powers with use of a defining impedance capability with a load character in mind. On the first stage, the computer simulation of transformer with a transformer ratio 4:1 in the band (40–240 MHz) was completed for limiting values of input and output resistances – 50 and 12,5 Ohms respectively. Results of simulation give us the data about constructive parameters of the transmission line. The measurement technique for insertion loss was worked out. The reason of that is an impossibility of appliance standard methods with using a network vector analyzer. The prototyping was done and values of the standing wave ratio and inserting losses were obtained for different levels of the input power. According to received data, it can be affirmed, that the manufactured transformer provides the standing wave ratio better (lower) that two. Inserting losses vary from 0,02 to 1,54 dB depending from a input power level (1– 1000 mW). The obtained results afford ground for working continuation in this field – a development of wideband transformers for matching of low-ohms loads.https://doklady.bsuir.by/jour/article/view/2421wideband matching networkscomplex impedancelow-impedance load
spellingShingle N. M. Naumovich
A. P. Joubko
M. V. Davydov
O. S. Maltsev
WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
wideband matching networks
complex impedance
low-impedance load
title WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
title_full WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
title_fullStr WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
title_full_unstemmed WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
title_short WIDEBAND TRANSFORMER FOR MATCHING OF LOW-IMPEDANCE LOADS IN VERY HIGH FREQUENCY RANGE
title_sort wideband transformer for matching of low impedance loads in very high frequency range
topic wideband matching networks
complex impedance
low-impedance load
url https://doklady.bsuir.by/jour/article/view/2421
work_keys_str_mv AT nmnaumovich widebandtransformerformatchingoflowimpedanceloadsinveryhighfrequencyrange
AT apjoubko widebandtransformerformatchingoflowimpedanceloadsinveryhighfrequencyrange
AT mvdavydov widebandtransformerformatchingoflowimpedanceloadsinveryhighfrequencyrange
AT osmaltsev widebandtransformerformatchingoflowimpedanceloadsinveryhighfrequencyrange