Prediction of the particle circulation rate in a draft tube spouted bed suspension dryer
A model for predicting the particle circulation rate in a draft tube spouted bed dryer with inert particles is proposed and verified. The calculation algorithm requires three input values: the gas velocity in the draft tube one data point for the static pressure in the draft tube, and the pressure g...
Päätekijät: | , , |
---|---|
Aineistotyyppi: | Artikkeli |
Kieli: | English |
Julkaistu: |
Serbian Chemical Society
2006-01-01
|
Sarja: | Journal of the Serbian Chemical Society |
Aiheet: | |
Linkit: | http://www.doiserbia.nb.rs/img/doi/0352-5139/2006/0352-51390604401A.pdf |