THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE

The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The l...

Full description

Bibliographic Details
Main Authors: Samira Boumous, Zouhir Boumous, Yacine Djeghader
Format: Article
Language:English
Published: Lublin University of Technology 2024-03-01
Series:Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Subjects:
Online Access:https://ph.pollub.pl/index.php/iapgos/article/view/5445
_version_ 1797233932578586624
author Samira Boumous
Zouhir Boumous
Yacine Djeghader
author_facet Samira Boumous
Zouhir Boumous
Yacine Djeghader
author_sort Samira Boumous
collection DOAJ
description The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The latest has many advantages over underground cables and overhead transmission lines, such as low transmission losses, less capacitive load, reliability, personal safety, same operation as overhead lines and negligible electrical aging. GIL can handle much more power than overhead lines due to its large conductive area. GIL is the best for high voltage. In this paper, the simulation of lightning strike effects on a 400 kV hybrid transmission line located in the Wilaya of Setif in northern Algeria is presented in the absence and presence of line arresters and GIL arresters. The results of this paper can provide a rich and valuable theoretical reference for GIL simulation modeling and evaluation of lightning strike impact on hybrid overhead – GIL lines.
first_indexed 2024-04-24T16:24:02Z
format Article
id doaj.art-dbbfc29b4697441b8430fa432728ea03
institution Directory Open Access Journal
issn 2083-0157
2391-6761
language English
last_indexed 2024-04-24T16:24:02Z
publishDate 2024-03-01
publisher Lublin University of Technology
record_format Article
series Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
spelling doaj.art-dbbfc29b4697441b8430fa432728ea032024-03-31T08:19:59ZengLublin University of TechnologyInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska2083-01572391-67612024-03-0114110.35784/iapgos.5445THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINESamira Boumous0https://orcid.org/0000-0003-2213-6542Zouhir Boumous1Yacine Djeghader2Mohamed Cherif Messaidia University, Electrical Engineering Department, Laboratory of Electrical Engineering and Renewable EnergyMohamed Cherif Messaidia University, Electrical Engineering Department, Laboratory of Electrical Engineering and Renewable EnergyMohamed Cherif Messaidia University, Electrical Engineering Department, Laboratory of Electrical Engineering and Renewable Energy The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The latest has many advantages over underground cables and overhead transmission lines, such as low transmission losses, less capacitive load, reliability, personal safety, same operation as overhead lines and negligible electrical aging. GIL can handle much more power than overhead lines due to its large conductive area. GIL is the best for high voltage. In this paper, the simulation of lightning strike effects on a 400 kV hybrid transmission line located in the Wilaya of Setif in northern Algeria is presented in the absence and presence of line arresters and GIL arresters. The results of this paper can provide a rich and valuable theoretical reference for GIL simulation modeling and evaluation of lightning strike impact on hybrid overhead – GIL lines. https://ph.pollub.pl/index.php/iapgos/article/view/5445overhead transmission linegas insulated linelightning strikesurge arrester
spellingShingle Samira Boumous
Zouhir Boumous
Yacine Djeghader
THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
overhead transmission line
gas insulated line
lightning strike
surge arrester
title THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
title_full THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
title_fullStr THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
title_full_unstemmed THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
title_short THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
title_sort impact of lightning strike on hybrid high voltage overhead transmission line insulated gas line
topic overhead transmission line
gas insulated line
lightning strike
surge arrester
url https://ph.pollub.pl/index.php/iapgos/article/view/5445
work_keys_str_mv AT samiraboumous theimpactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline
AT zouhirboumous theimpactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline
AT yacinedjeghader theimpactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline
AT samiraboumous impactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline
AT zouhirboumous impactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline
AT yacinedjeghader impactoflightningstrikeonhybridhighvoltageoverheadtransmissionlineinsulatedgasline