Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer

Today important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equ...

Full description

Bibliographic Details
Main Authors: V. A. Khrustalev, D. O. Bashlykov, M. V. Garievsky
Format: Article
Language:English
Published: Kazan State Power Engineering University 2018-02-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/418
_version_ 1797762223047704576
author V. A. Khrustalev
D. O. Bashlykov
M. V. Garievsky
author_facet V. A. Khrustalev
D. O. Bashlykov
M. V. Garievsky
author_sort V. A. Khrustalev
collection DOAJ
description Today important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equipment is the basis not only of the stability of large power systems in modes with violation of the frequency but also safety of the nuclear power plants, Проблемы энергетики, 2017, том 19, № 7-8 95 which would ensure cooling of the reactor during an accident.Therefore, the necessary capabilities of rapid discharges and increase in the load in large nuclear power plants, selected for emergency frequency control. High voltage variable frequency drives (VFD) of the main circulation pumps are able to provide the necessary reserve of growth power.Installation VFD of the MCPs are suitable for saving energy consumption in their drive on the partial regimes and to improve the stability of the neutron-physical active zone characteristics in variable modes.Using VFD of the MCPs can reduce increase pressures in the steam generators in the respective modes, restricting flow the coolant with a constant average temperature in the active zone of reactor, and therefore to reduce the energy consumption of the feed pump.
first_indexed 2024-03-12T19:24:12Z
format Article
id doaj.art-dbe0bb7852e341499cd2d1cff634b321
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2024-03-12T19:24:12Z
publishDate 2018-02-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-dbe0bb7852e341499cd2d1cff634b3212023-08-02T04:57:50ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032018-02-01197-89410410.30724/1998-9903-2017-19-7-8-94-104418Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwerV. A. Khrustalev0D. O. Bashlykov1M. V. Garievsky2Yuri Gagarin State Technical University of Saratov, SaratovYuri Gagarin State Technical University of Saratov, SaratovSaratov Scientific Center, Russian Academy of Sciences, SaratovToday important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equipment is the basis not only of the stability of large power systems in modes with violation of the frequency but also safety of the nuclear power plants, Проблемы энергетики, 2017, том 19, № 7-8 95 which would ensure cooling of the reactor during an accident.Therefore, the necessary capabilities of rapid discharges and increase in the load in large nuclear power plants, selected for emergency frequency control. High voltage variable frequency drives (VFD) of the main circulation pumps are able to provide the necessary reserve of growth power.Installation VFD of the MCPs are suitable for saving energy consumption in their drive on the partial regimes and to improve the stability of the neutron-physical active zone characteristics in variable modes.Using VFD of the MCPs can reduce increase pressures in the steam generators in the respective modes, restricting flow the coolant with a constant average temperature in the active zone of reactor, and therefore to reduce the energy consumption of the feed pump.https://www.energyret.ru/jour/article/view/418nuclear power plantmain circulating pumphigh-voltage variable-frequency driveregulation of reactor power
spellingShingle V. A. Khrustalev
D. O. Bashlykov
M. V. Garievsky
Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
Известия высших учебных заведений: Проблемы энергетики
nuclear power plant
main circulating pump
high-voltage variable-frequency drive
regulation of reactor power
title Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
title_full Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
title_fullStr Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
title_full_unstemmed Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
title_short Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
title_sort efficiency problems of high voltage variable frequency drives of the mcp of npp with wwer
topic nuclear power plant
main circulating pump
high-voltage variable-frequency drive
regulation of reactor power
url https://www.energyret.ru/jour/article/view/418
work_keys_str_mv AT vakhrustalev efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer
AT dobashlykov efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer
AT mvgarievsky efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer