Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer
Today important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equ...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kazan State Power Engineering University
2018-02-01
|
Series: | Известия высших учебных заведений: Проблемы энергетики |
Subjects: | |
Online Access: | https://www.energyret.ru/jour/article/view/418 |
_version_ | 1797762223047704576 |
---|---|
author | V. A. Khrustalev D. O. Bashlykov M. V. Garievsky |
author_facet | V. A. Khrustalev D. O. Bashlykov M. V. Garievsky |
author_sort | V. A. Khrustalev |
collection | DOAJ |
description | Today important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equipment is the basis not only of the stability of large power systems in modes with violation of the frequency but also safety of the nuclear power plants, Проблемы энергетики, 2017, том 19, № 7-8 95 which would ensure cooling of the reactor during an accident.Therefore, the necessary capabilities of rapid discharges and increase in the load in large nuclear power plants, selected for emergency frequency control. High voltage variable frequency drives (VFD) of the main circulation pumps are able to provide the necessary reserve of growth power.Installation VFD of the MCPs are suitable for saving energy consumption in their drive on the partial regimes and to improve the stability of the neutron-physical active zone characteristics in variable modes.Using VFD of the MCPs can reduce increase pressures in the steam generators in the respective modes, restricting flow the coolant with a constant average temperature in the active zone of reactor, and therefore to reduce the energy consumption of the feed pump. |
first_indexed | 2024-03-12T19:24:12Z |
format | Article |
id | doaj.art-dbe0bb7852e341499cd2d1cff634b321 |
institution | Directory Open Access Journal |
issn | 1998-9903 |
language | English |
last_indexed | 2024-03-12T19:24:12Z |
publishDate | 2018-02-01 |
publisher | Kazan State Power Engineering University |
record_format | Article |
series | Известия высших учебных заведений: Проблемы энергетики |
spelling | doaj.art-dbe0bb7852e341499cd2d1cff634b3212023-08-02T04:57:50ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032018-02-01197-89410410.30724/1998-9903-2017-19-7-8-94-104418Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwerV. A. Khrustalev0D. O. Bashlykov1M. V. Garievsky2Yuri Gagarin State Technical University of Saratov, SaratovYuri Gagarin State Technical University of Saratov, SaratovSaratov Scientific Center, Russian Academy of Sciences, SaratovToday important is the scientific study of solutions to the problem of participation of nuclear power plants, both existing and newly built, in the regulation of load schedules.However unacceptable a significant reduction of the capacity factor of nuclear power plants. Sufficient flexible of NPP equipment is the basis not only of the stability of large power systems in modes with violation of the frequency but also safety of the nuclear power plants, Проблемы энергетики, 2017, том 19, № 7-8 95 which would ensure cooling of the reactor during an accident.Therefore, the necessary capabilities of rapid discharges and increase in the load in large nuclear power plants, selected for emergency frequency control. High voltage variable frequency drives (VFD) of the main circulation pumps are able to provide the necessary reserve of growth power.Installation VFD of the MCPs are suitable for saving energy consumption in their drive on the partial regimes and to improve the stability of the neutron-physical active zone characteristics in variable modes.Using VFD of the MCPs can reduce increase pressures in the steam generators in the respective modes, restricting flow the coolant with a constant average temperature in the active zone of reactor, and therefore to reduce the energy consumption of the feed pump.https://www.energyret.ru/jour/article/view/418nuclear power plantmain circulating pumphigh-voltage variable-frequency driveregulation of reactor power |
spellingShingle | V. A. Khrustalev D. O. Bashlykov M. V. Garievsky Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer Известия высших учебных заведений: Проблемы энергетики nuclear power plant main circulating pump high-voltage variable-frequency drive regulation of reactor power |
title | Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer |
title_full | Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer |
title_fullStr | Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer |
title_full_unstemmed | Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer |
title_short | Efficiency problems of high-voltage variable frequency drives of the mcp of npp with wwer |
title_sort | efficiency problems of high voltage variable frequency drives of the mcp of npp with wwer |
topic | nuclear power plant main circulating pump high-voltage variable-frequency drive regulation of reactor power |
url | https://www.energyret.ru/jour/article/view/418 |
work_keys_str_mv | AT vakhrustalev efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer AT dobashlykov efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer AT mvgarievsky efficiencyproblemsofhighvoltagevariablefrequencydrivesofthemcpofnppwithwwer |