Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine

Abstract Background and Objective: Automated Teller Machine (ATMs) is likely to be contaminated with various microorganisms specially pathogen germs. This may be due to their exposure to dust and their vast dermal contact with multiple users. This study investigated the bacterial contamination on...

Full description

Bibliographic Details
Main Authors: Moshtaghi, H, Parsa, M
Format: Article
Language:English
Published: Golestan University of Medical Sciences 2015-04-01
Series:Medical Laboratory Journal
Subjects:
Online Access:http://mlj.goums.ac.ir/article-1-603-en.html
_version_ 1819077982178770944
author Moshtaghi, H
Parsa, M
author_facet Moshtaghi, H
Parsa, M
author_sort Moshtaghi, H
collection DOAJ
description Abstract Background and Objective: Automated Teller Machine (ATMs) is likely to be contaminated with various microorganisms specially pathogen germs. This may be due to their exposure to dust and their vast dermal contact with multiple users. This study investigated the bacterial contamination on the keyboard of ATMs and drug resistance of the bacteria isolated from them. Material and Methods: the keyboards of 50 ATMs in Shahrekord city, Iran, were examined from October 2012 to February 2013. The sterile swab sticks moistened with Triptose soy broth were used for sampling. The bacteriological tests used were culture, biochemical test and agar disk diffusion method for antibiogram. Results: All the samples were found to be contaminated with Coagulase negative staphylococci (57.54%), Bacillus species (21.92%), Staphylococcus aureus (19.18%) and coliform bacteria (1.36%). The resistance of Staphylococcus aureus was 92.8% to penicillin, 85.7% to amoxicilin، 71.4% to ampicillin, 57.1% to nytrofuran, 50% to tetracycline, 42.8% to erythromycin, 42.8% to gentamycin, 14.2 % to ciprofloxacin, 7.1% to trimethoprim and sulfamtuksazul. All species were susceptible to, ofloxacine, chloramphenicol, clindamycin, tobramycin, vancomycin and cefotaxime. Conclusion: given the presence of pathogens on ATMs and their role in transferring the contamination, we recommend considering personal hygiene and periodically disinfecting the keyboards to reduce contamination. Keywords: ATMs, Bacterial Contamination, Antibiogram
first_indexed 2024-12-21T19:05:51Z
format Article
id doaj.art-dc09569d658b4348bae5d6736bc50058
institution Directory Open Access Journal
issn 2538-4449
language English
last_indexed 2024-12-21T19:05:51Z
publishDate 2015-04-01
publisher Golestan University of Medical Sciences
record_format Article
series Medical Laboratory Journal
spelling doaj.art-dc09569d658b4348bae5d6736bc500582022-12-21T18:53:20ZengGolestan University of Medical SciencesMedical Laboratory Journal2538-44492015-04-01913944Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller MachineMoshtaghi, H0Parsa, M1 School of Veterinary Medicine, Shahrekord University, Shahrekord, Iran School of Veterinary Medicine, Shahrekord University, Shahrekord, Iran. Abstract Background and Objective: Automated Teller Machine (ATMs) is likely to be contaminated with various microorganisms specially pathogen germs. This may be due to their exposure to dust and their vast dermal contact with multiple users. This study investigated the bacterial contamination on the keyboard of ATMs and drug resistance of the bacteria isolated from them. Material and Methods: the keyboards of 50 ATMs in Shahrekord city, Iran, were examined from October 2012 to February 2013. The sterile swab sticks moistened with Triptose soy broth were used for sampling. The bacteriological tests used were culture, biochemical test and agar disk diffusion method for antibiogram. Results: All the samples were found to be contaminated with Coagulase negative staphylococci (57.54%), Bacillus species (21.92%), Staphylococcus aureus (19.18%) and coliform bacteria (1.36%). The resistance of Staphylococcus aureus was 92.8% to penicillin, 85.7% to amoxicilin، 71.4% to ampicillin, 57.1% to nytrofuran, 50% to tetracycline, 42.8% to erythromycin, 42.8% to gentamycin, 14.2 % to ciprofloxacin, 7.1% to trimethoprim and sulfamtuksazul. All species were susceptible to, ofloxacine, chloramphenicol, clindamycin, tobramycin, vancomycin and cefotaxime. Conclusion: given the presence of pathogens on ATMs and their role in transferring the contamination, we recommend considering personal hygiene and periodically disinfecting the keyboards to reduce contamination. Keywords: ATMs, Bacterial Contamination, Antibiogramhttp://mlj.goums.ac.ir/article-1-603-en.htmlatmsbacterial contaminationantibiogram
spellingShingle Moshtaghi, H
Parsa, M
Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
Medical Laboratory Journal
atms
bacterial contamination
antibiogram
title Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
title_full Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
title_fullStr Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
title_full_unstemmed Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
title_short Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine
title_sort bacterial contamination and antibiotic resistance of staphylococcus aureus isolated from automated teller machine
topic atms
bacterial contamination
antibiogram
url http://mlj.goums.ac.ir/article-1-603-en.html
work_keys_str_mv AT moshtaghih bacterialcontaminationandantibioticresistanceofstaphylococcusaureusisolatedfromautomatedtellermachine
AT parsam bacterialcontaminationandantibioticresistanceofstaphylococcusaureusisolatedfromautomatedtellermachine