A Method for Efficiency Determination of Permanent Magnet Synchronous Motor
The utilization rate of permanent magnet synchronous motors (PMSM) is increasing in the industry today. Due to this fact, the high efficiency ratio of PMSMs has reached IE5 premium class efficiency. Therefore, the efficiency coefficient of the PMSM varies from 92% to 97%. As a result, this type of m...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-02-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/13/4/1004 |
_version_ | 1798006700886720512 |
---|---|
author | Karolis Dambrauskas Jonas Vanagas Tomas Zimnickas Artūras Kalvaitis Mindaugas Ažubalis |
author_facet | Karolis Dambrauskas Jonas Vanagas Tomas Zimnickas Artūras Kalvaitis Mindaugas Ažubalis |
author_sort | Karolis Dambrauskas |
collection | DOAJ |
description | The utilization rate of permanent magnet synchronous motors (PMSM) is increasing in the industry today. Due to this fact, the high efficiency ratio of PMSMs has reached IE5 premium class efficiency. Therefore, the efficiency coefficient of the PMSM varies from 92% to 97%. As a result, this type of motor is replacing traditional asynchronous motor by falling into efficiency classes of IE1, IE2, IE3, and IE4, which range from 75% to 92% in the industry. Thus, the object of the research was to develop a method to determine the efficiency of permanent magnet synchronous motor applications in order to identify and verify the variating parameters. In this study, an innovative and safe method of PMSM testing when the nominal parameters of the motor are unknown was presented through research. Also, the comparison of PMSM oscillograms with different types of load types and phase shift oscillograms, generated using operation amplifier, were analyzed and is scrutinized. During the design process, the PMSM was projected for the IE5 premium efficiency class. However, after production, the PMSM sometimes does not match the nameplate parameters, which are declared by the factory. As a result, during the testing procedures, the PMSM nameplate parameters did not match the projected parameters. Facing the problem of the projected and tested efficiency mismatch, the PMSM highest efficiency determination experiments were performed in a laboratory in order to prove the highest efficiency of the PMSM. The results showed different PMSM input parameters. Furthermore, the experimental results of the PMSM testing were confirmed with electrical machines theory, and simulation results were performed with electrical circuits. The theory of PMSM operating in different values of input voltage is represented in graphical abstract. |
first_indexed | 2024-04-11T12:58:48Z |
format | Article |
id | doaj.art-dc1f307361404f4784be58d66be655d7 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-04-11T12:58:48Z |
publishDate | 2020-02-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-dc1f307361404f4784be58d66be655d72022-12-22T04:23:00ZengMDPI AGEnergies1996-10732020-02-01134100410.3390/en13041004en13041004A Method for Efficiency Determination of Permanent Magnet Synchronous MotorKarolis Dambrauskas0Jonas Vanagas1Tomas Zimnickas2Artūras Kalvaitis3Mindaugas Ažubalis4Department of Power Systems, Kaunas University of Technology, LT51367 Kaunas, LithuaniaDepartment of Power Systems, Kaunas University of Technology, LT51367 Kaunas, LithuaniaDepartment of Power Systems, Kaunas University of Technology, LT51367 Kaunas, LithuaniaDepartment of Power Systems, Kaunas University of Technology, LT51367 Kaunas, LithuaniaDepartment of Power Systems, Kaunas University of Technology, LT51367 Kaunas, LithuaniaThe utilization rate of permanent magnet synchronous motors (PMSM) is increasing in the industry today. Due to this fact, the high efficiency ratio of PMSMs has reached IE5 premium class efficiency. Therefore, the efficiency coefficient of the PMSM varies from 92% to 97%. As a result, this type of motor is replacing traditional asynchronous motor by falling into efficiency classes of IE1, IE2, IE3, and IE4, which range from 75% to 92% in the industry. Thus, the object of the research was to develop a method to determine the efficiency of permanent magnet synchronous motor applications in order to identify and verify the variating parameters. In this study, an innovative and safe method of PMSM testing when the nominal parameters of the motor are unknown was presented through research. Also, the comparison of PMSM oscillograms with different types of load types and phase shift oscillograms, generated using operation amplifier, were analyzed and is scrutinized. During the design process, the PMSM was projected for the IE5 premium efficiency class. However, after production, the PMSM sometimes does not match the nameplate parameters, which are declared by the factory. As a result, during the testing procedures, the PMSM nameplate parameters did not match the projected parameters. Facing the problem of the projected and tested efficiency mismatch, the PMSM highest efficiency determination experiments were performed in a laboratory in order to prove the highest efficiency of the PMSM. The results showed different PMSM input parameters. Furthermore, the experimental results of the PMSM testing were confirmed with electrical machines theory, and simulation results were performed with electrical circuits. The theory of PMSM operating in different values of input voltage is represented in graphical abstract.https://www.mdpi.com/1996-1073/13/4/1004permanent magnet synchronous motor (pmsm)torquerevolutions per minuteefficiencyelectromotive force |
spellingShingle | Karolis Dambrauskas Jonas Vanagas Tomas Zimnickas Artūras Kalvaitis Mindaugas Ažubalis A Method for Efficiency Determination of Permanent Magnet Synchronous Motor Energies permanent magnet synchronous motor (pmsm) torque revolutions per minute efficiency electromotive force |
title | A Method for Efficiency Determination of Permanent Magnet Synchronous Motor |
title_full | A Method for Efficiency Determination of Permanent Magnet Synchronous Motor |
title_fullStr | A Method for Efficiency Determination of Permanent Magnet Synchronous Motor |
title_full_unstemmed | A Method for Efficiency Determination of Permanent Magnet Synchronous Motor |
title_short | A Method for Efficiency Determination of Permanent Magnet Synchronous Motor |
title_sort | method for efficiency determination of permanent magnet synchronous motor |
topic | permanent magnet synchronous motor (pmsm) torque revolutions per minute efficiency electromotive force |
url | https://www.mdpi.com/1996-1073/13/4/1004 |
work_keys_str_mv | AT karolisdambrauskas amethodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT jonasvanagas amethodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT tomaszimnickas amethodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT arturaskalvaitis amethodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT mindaugasazubalis amethodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT karolisdambrauskas methodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT jonasvanagas methodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT tomaszimnickas methodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT arturaskalvaitis methodforefficiencydeterminationofpermanentmagnetsynchronousmotor AT mindaugasazubalis methodforefficiencydeterminationofpermanentmagnetsynchronousmotor |