Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments

Mateusz Krakowiak,1 Natalia Rulewska,2 Marcin Rudaś,1 Maciej Broda,1 Michał Sabramowicz,1 Andrzej Jaremko,1 Krzysztof Leki,3 Paweł Sokal1 1Department of Neurosurgery and Neurology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland; 2Students’ Scien...

Full description

Bibliographic Details
Main Authors: Krakowiak M, Rulewska N, Rudaś M, Broda M, Sabramowicz M, Jaremko A, Leki K, Sokal P
Format: Article
Language:English
Published: Dove Medical Press 2022-07-01
Series:Journal of Pain Research
Subjects:
Online Access:https://www.dovepress.com/interspinous-process-devices-do-not-reduce-intervertebral-foramina-and-peer-reviewed-fulltext-article-JPR
_version_ 1818534684990111744
author Krakowiak M
Rulewska N
Rudaś M
Broda M
Sabramowicz M
Jaremko A
Leki K
Sokal P
author_facet Krakowiak M
Rulewska N
Rudaś M
Broda M
Sabramowicz M
Jaremko A
Leki K
Sokal P
author_sort Krakowiak M
collection DOAJ
description Mateusz Krakowiak,1 Natalia Rulewska,2 Marcin Rudaś,1 Maciej Broda,1 Michał Sabramowicz,1 Andrzej Jaremko,1 Krzysztof Leki,3 Paweł Sokal1 1Department of Neurosurgery and Neurology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland; 2Students’ Scientific Circle at the Department of Neurosurgery, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland; 3Centre for Statistical Analysis, Nicolaus Copernicus University, Toruń, PolandCorrespondence: Paweł Sokal, Department of Neurosurgery and Neurology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland, Tel/Fax +48 523655505, Email pawel.sokal@cm.umk.plAim: Interspinous process device (IPD) placement is an attractive treatment option for lumbar spinal and foraminal stenosis. The goal of the treatment is to release the stress on facets joints as well as decompress the nerve roots by enlarging the intervertebral foramina and narrowed canal recesses.Purpose: To evaluate possible structural changes in the lumbar spine after implantation of an IPD on operated and adjacent segments.Patients and Methods: Twenty-two patients were enrolled in the study. Preoperative MRI scans of the lumbar spine evaluated recess and foraminal stenosis prior to the application of an IPD. CT exams were performed and morphometric measurements were made to assess the size of intervertebral foramina after implantation on the operated and adjacent segments.Results: Statistically significant enlargements in diameter and surface area of the intervertebral foramen were seen at the operating level. On the right and left sides, foraminal enlargement after the procedure was 1 mm in diameter. The average enlargement of the foramina surface area at the level of implantation was 10 mm2. The median interspinous distance was significantly enlarged by 3.5 mm. No significant changes in adjacent segments were observed. Clinical improvement was confirmed by the Oswestry Disability Index (ODI) and visual analog scale (VAS). Preoperative disability was reduced (mean ODI from 70.5 (12.25) to 49.5 (23.75)), as well as back pain (mean VAS from 8.0 (1.7) to 4.4 (2.6)) and pain in lower limbs (mean VAS from 7.4 (1.9) to 3.8 (2.9)).Conclusion: Decompression surgery using an IPD is effective in the treatment of lumbar foraminal and canal stenosis. It provides relief of symptoms in short-term observation through enlargement of intervertebral foramina and decompression of neural roots. It reduces overload of facet joints of the operated segment and does not decrease the size of the intervertebral foramina and disc heights of adjacent segments.Keywords: interspinous device, low lumbar back pain, lumbar decompression, spinal canal stenosis, foraminal stenosis
first_indexed 2024-12-11T18:14:46Z
format Article
id doaj.art-dc3028766d14487aa34af87b10582230
institution Directory Open Access Journal
issn 1178-7090
language English
last_indexed 2024-12-11T18:14:46Z
publishDate 2022-07-01
publisher Dove Medical Press
record_format Article
series Journal of Pain Research
spelling doaj.art-dc3028766d14487aa34af87b105822302022-12-22T00:55:28ZengDove Medical PressJournal of Pain Research1178-70902022-07-01Volume 151971198276580Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent SegmentsKrakowiak MRulewska NRudaś MBroda MSabramowicz MJaremko ALeki KSokal PMateusz Krakowiak,1 Natalia Rulewska,2 Marcin Rudaś,1 Maciej Broda,1 Michał Sabramowicz,1 Andrzej Jaremko,1 Krzysztof Leki,3 Paweł Sokal1 1Department of Neurosurgery and Neurology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland; 2Students’ Scientific Circle at the Department of Neurosurgery, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland; 3Centre for Statistical Analysis, Nicolaus Copernicus University, Toruń, PolandCorrespondence: Paweł Sokal, Department of Neurosurgery and Neurology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland, Tel/Fax +48 523655505, Email pawel.sokal@cm.umk.plAim: Interspinous process device (IPD) placement is an attractive treatment option for lumbar spinal and foraminal stenosis. The goal of the treatment is to release the stress on facets joints as well as decompress the nerve roots by enlarging the intervertebral foramina and narrowed canal recesses.Purpose: To evaluate possible structural changes in the lumbar spine after implantation of an IPD on operated and adjacent segments.Patients and Methods: Twenty-two patients were enrolled in the study. Preoperative MRI scans of the lumbar spine evaluated recess and foraminal stenosis prior to the application of an IPD. CT exams were performed and morphometric measurements were made to assess the size of intervertebral foramina after implantation on the operated and adjacent segments.Results: Statistically significant enlargements in diameter and surface area of the intervertebral foramen were seen at the operating level. On the right and left sides, foraminal enlargement after the procedure was 1 mm in diameter. The average enlargement of the foramina surface area at the level of implantation was 10 mm2. The median interspinous distance was significantly enlarged by 3.5 mm. No significant changes in adjacent segments were observed. Clinical improvement was confirmed by the Oswestry Disability Index (ODI) and visual analog scale (VAS). Preoperative disability was reduced (mean ODI from 70.5 (12.25) to 49.5 (23.75)), as well as back pain (mean VAS from 8.0 (1.7) to 4.4 (2.6)) and pain in lower limbs (mean VAS from 7.4 (1.9) to 3.8 (2.9)).Conclusion: Decompression surgery using an IPD is effective in the treatment of lumbar foraminal and canal stenosis. It provides relief of symptoms in short-term observation through enlargement of intervertebral foramina and decompression of neural roots. It reduces overload of facet joints of the operated segment and does not decrease the size of the intervertebral foramina and disc heights of adjacent segments.Keywords: interspinous device, low lumbar back pain, lumbar decompression, spinal canal stenosis, foraminal stenosishttps://www.dovepress.com/interspinous-process-devices-do-not-reduce-intervertebral-foramina-and-peer-reviewed-fulltext-article-JPRinterspinous devicelow lumbar back painlumbar decompressionspinal canal stenosisforaminal stenosis.
spellingShingle Krakowiak M
Rulewska N
Rudaś M
Broda M
Sabramowicz M
Jaremko A
Leki K
Sokal P
Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
Journal of Pain Research
interspinous device
low lumbar back pain
lumbar decompression
spinal canal stenosis
foraminal stenosis.
title Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
title_full Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
title_fullStr Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
title_full_unstemmed Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
title_short Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments
title_sort interspinous process devices do not reduce intervertebral foramina and discs heights on adjacent segments
topic interspinous device
low lumbar back pain
lumbar decompression
spinal canal stenosis
foraminal stenosis.
url https://www.dovepress.com/interspinous-process-devices-do-not-reduce-intervertebral-foramina-and-peer-reviewed-fulltext-article-JPR
work_keys_str_mv AT krakowiakm interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT rulewskan interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT rudasm interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT brodam interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT sabramowiczm interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT jaremkoa interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT lekik interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments
AT sokalp interspinousprocessdevicesdonotreduceintervertebralforaminaanddiscsheightsonadjacentsegments