Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls

Institutions such as ICOFORT (International committee on fortifications and military heritage) encourages the development of diagnosis strategies for the conservation and maintenance of historic earthen walls as highly necessary. Thus, it is important to be aware of the conditions in urban contexts,...

Full description

Bibliographic Details
Main Authors: Álvaro R. Serrano-Chacón, Emilio J. Mascort-Albea, Jacinto Canivell, Rocío Romero-Hernández, Antonio Jaramillo-Morilla
Format: Article
Language:English
Published: MDPI AG 2021-03-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/11/6/2744
_version_ 1797540873319219200
author Álvaro R. Serrano-Chacón
Emilio J. Mascort-Albea
Jacinto Canivell
Rocío Romero-Hernández
Antonio Jaramillo-Morilla
author_facet Álvaro R. Serrano-Chacón
Emilio J. Mascort-Albea
Jacinto Canivell
Rocío Romero-Hernández
Antonio Jaramillo-Morilla
author_sort Álvaro R. Serrano-Chacón
collection DOAJ
description Institutions such as ICOFORT (International committee on fortifications and military heritage) encourages the development of diagnosis strategies for the conservation and maintenance of historic earthen walls as highly necessary. Thus, it is important to be aware of the conditions in urban contexts, where the deterioration can be more aggressive and the risk of damage increases. Despite this, there are many strategies of constructive diagnosis for these kinds of monuments, but not many of them are concerned with the structural assessment of situations in which the ramparts work as a retaining wall in an unforeseen way. The medieval ramparts of Seville (Spain) are shown as a completely representative case study of the above-mentioned situation. In the research sector, the monument resists the lateral earth pressure developed by the new difference in height at both sides of the wall. Based on the limited states principle and on different international codes formulation, a tool was programmed to carry out automatic calculations to verify the case study’s overall stability conditions using standard sections. The obtained results were based on the overturning, bearing, and sliding overdesign factors (ODF) and determined a stable situation that could be at risk because of changes in the surrounding such as, excavations or the movements of the ground water table, or seismic events. Thus, the need and usefulness of strategies and control instruments that should be integrated into heritage intervention projects have been proved.
first_indexed 2024-03-10T13:07:14Z
format Article
id doaj.art-dc7cd9a3a1404a7c9cf974cdf87d297d
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-10T13:07:14Z
publishDate 2021-03-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-dc7cd9a3a1404a7c9cf974cdf87d297d2023-11-21T11:05:11ZengMDPI AGApplied Sciences2076-34172021-03-01116274410.3390/app11062744Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining WallsÁlvaro R. Serrano-Chacón0Emilio J. Mascort-Albea1Jacinto Canivell2Rocío Romero-Hernández3Antonio Jaramillo-Morilla4Departamento de Estructuras de Edificación e Ingeniería del Terreno, Escuela Técnica Superior de Arquitectura, Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41012 Seville, SpainDepartamento de Estructuras de Edificación e Ingeniería del Terreno, Escuela Técnica Superior de Arquitectura, Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41012 Seville, SpainDepartamento de Construcciones Arquitectónicas II, Escuela Técnica Superior de Ingeniería de la Edificación, Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41013 Seville, SpainDepartamento de Estructuras de Edificación e Ingeniería del Terreno, Escuela Técnica Superior de Arquitectura, Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41012 Seville, SpainDepartamento de Estructuras de Edificación e Ingeniería del Terreno, Escuela Técnica Superior de Arquitectura, Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41012 Seville, SpainInstitutions such as ICOFORT (International committee on fortifications and military heritage) encourages the development of diagnosis strategies for the conservation and maintenance of historic earthen walls as highly necessary. Thus, it is important to be aware of the conditions in urban contexts, where the deterioration can be more aggressive and the risk of damage increases. Despite this, there are many strategies of constructive diagnosis for these kinds of monuments, but not many of them are concerned with the structural assessment of situations in which the ramparts work as a retaining wall in an unforeseen way. The medieval ramparts of Seville (Spain) are shown as a completely representative case study of the above-mentioned situation. In the research sector, the monument resists the lateral earth pressure developed by the new difference in height at both sides of the wall. Based on the limited states principle and on different international codes formulation, a tool was programmed to carry out automatic calculations to verify the case study’s overall stability conditions using standard sections. The obtained results were based on the overturning, bearing, and sliding overdesign factors (ODF) and determined a stable situation that could be at risk because of changes in the surrounding such as, excavations or the movements of the ground water table, or seismic events. Thus, the need and usefulness of strategies and control instruments that should be integrated into heritage intervention projects have been proved.https://www.mdpi.com/2076-3417/11/6/2744building heritagerammed earthlimit statescalculation methodsretaining walls
spellingShingle Álvaro R. Serrano-Chacón
Emilio J. Mascort-Albea
Jacinto Canivell
Rocío Romero-Hernández
Antonio Jaramillo-Morilla
Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
Applied Sciences
building heritage
rammed earth
limit states
calculation methods
retaining walls
title Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
title_full Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
title_fullStr Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
title_full_unstemmed Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
title_short Multi-Criteria Parametric Verifications for Stability Diagnosis of Rammed-Earth Historic Urban Ramparts Working as Retaining Walls
title_sort multi criteria parametric verifications for stability diagnosis of rammed earth historic urban ramparts working as retaining walls
topic building heritage
rammed earth
limit states
calculation methods
retaining walls
url https://www.mdpi.com/2076-3417/11/6/2744
work_keys_str_mv AT alvarorserranochacon multicriteriaparametricverificationsforstabilitydiagnosisoframmedearthhistoricurbanrampartsworkingasretainingwalls
AT emiliojmascortalbea multicriteriaparametricverificationsforstabilitydiagnosisoframmedearthhistoricurbanrampartsworkingasretainingwalls
AT jacintocanivell multicriteriaparametricverificationsforstabilitydiagnosisoframmedearthhistoricurbanrampartsworkingasretainingwalls
AT rocioromerohernandez multicriteriaparametricverificationsforstabilitydiagnosisoframmedearthhistoricurbanrampartsworkingasretainingwalls
AT antoniojaramillomorilla multicriteriaparametricverificationsforstabilitydiagnosisoframmedearthhistoricurbanrampartsworkingasretainingwalls