Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring
Background To compare the biomechanical stability of a novel, C-shaped nickel–titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). Methods In total, 18 synthetic femoral fracture models were...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2024-03-01
|
Series: | Journal of International Medical Research |
Online Access: | https://doi.org/10.1177/03000605241240946 |
_version_ | 1797234224078520320 |
---|---|
author | Seog-Hyun Oh Yu-Sung Suh Emmanuel Eghan-Acquah Kollerov Mikhail Yurevich Sung-Hun Won Min Jung Baek Sung-Jae Lee Sung-Woo Choi |
author_facet | Seog-Hyun Oh Yu-Sung Suh Emmanuel Eghan-Acquah Kollerov Mikhail Yurevich Sung-Hun Won Min Jung Baek Sung-Jae Lee Sung-Woo Choi |
author_sort | Seog-Hyun Oh |
collection | DOAJ |
description | Background To compare the biomechanical stability of a novel, C-shaped nickel–titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). Methods In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. Results The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39–41) and 35 (35–35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44–0.45) and 0.30 (0.30–0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39–41) and 28 (28–31) N/mm; for the C-clip and cerclage wiring, respectively. Conclusion Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results. |
first_indexed | 2024-04-24T16:28:40Z |
format | Article |
id | doaj.art-dca177dd8c9448b5b0ed2f651fe16996 |
institution | Directory Open Access Journal |
issn | 1473-2300 |
language | English |
last_indexed | 2024-04-24T16:28:40Z |
publishDate | 2024-03-01 |
publisher | SAGE Publishing |
record_format | Article |
series | Journal of International Medical Research |
spelling | doaj.art-dca177dd8c9448b5b0ed2f651fe169962024-03-30T11:05:25ZengSAGE PublishingJournal of International Medical Research1473-23002024-03-015210.1177/03000605241240946Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiringSeog-Hyun OhYu-Sung SuhEmmanuel Eghan-AcquahKollerov Mikhail YurevichSung-Hun WonMin Jung BaekSung-Jae LeeSung-Woo ChoiBackground To compare the biomechanical stability of a novel, C-shaped nickel–titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). Methods In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. Results The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39–41) and 35 (35–35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44–0.45) and 0.30 (0.30–0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39–41) and 28 (28–31) N/mm; for the C-clip and cerclage wiring, respectively. Conclusion Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.https://doi.org/10.1177/03000605241240946 |
spellingShingle | Seog-Hyun Oh Yu-Sung Suh Emmanuel Eghan-Acquah Kollerov Mikhail Yurevich Sung-Hun Won Min Jung Baek Sung-Jae Lee Sung-Woo Choi Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring Journal of International Medical Research |
title | Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring |
title_full | Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring |
title_fullStr | Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring |
title_full_unstemmed | Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring |
title_short | Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring |
title_sort | unstable vancouver b1 periprosthetic femoral fracture fixation a biomechanical comparison between a novel c shaped memory alloy implant and cerclage wiring |
url | https://doi.org/10.1177/03000605241240946 |
work_keys_str_mv | AT seoghyunoh unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT yusungsuh unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT emmanueleghanacquah unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT kollerovmikhailyurevich unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT sunghunwon unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT minjungbaek unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT sungjaelee unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring AT sungwoochoi unstablevancouverb1periprostheticfemoralfracturefixationabiomechanicalcomparisonbetweenanovelcshapedmemoryalloyimplantandcerclagewiring |