IGBT Temperature Field Monitoring Based on Reduced-order Model

With the rapid development of the world economy, IGBT has been widely used in motor drive and electric energy conversion. In order to timely detect the fatigue damage of IGBT, it is necessary to monitor the junction temperature of IGBT. In order to realize the fast calculation of IGBT junction tempe...

Full description

Bibliographic Details
Main Authors: Ziyu Zhou, Yi Sui, Xu Zhang, Chengde Tong, Ping Zheng, Mingjun Zhu
Format: Article
Language:English
Published: China Electrotechnical Society 2023-06-01
Series:CES Transactions on Electrical Machines and Systems
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10018850
_version_ 1797755701020327936
author Ziyu Zhou
Yi Sui
Xu Zhang
Chengde Tong
Ping Zheng
Mingjun Zhu
author_facet Ziyu Zhou
Yi Sui
Xu Zhang
Chengde Tong
Ping Zheng
Mingjun Zhu
author_sort Ziyu Zhou
collection DOAJ
description With the rapid development of the world economy, IGBT has been widely used in motor drive and electric energy conversion. In order to timely detect the fatigue damage of IGBT, it is necessary to monitor the junction temperature of IGBT. In order to realize the fast calculation of IGBT junction temperature, a finite element method of IGBT temperature field reduction is proposed in this paper. Firstly, the finite element calculation process of IGBT temperature field is introduced and the linear equations of finite element calculation of temperature field are derived. Temperature field data of different working conditions are obtained by finite element simulation to form the sample space. Then the covariance matrix of the sample space is constructed, whose proper orthogonal decomposition and modal extraction are carried out. Reasonable basis vector space is selected to complete the low dimensional expression of temperature vector inside and outside the sample space. Finally, the reduced-order model of temperature field finite element is obtained and solved. The results of the reduced order model are compared with those of the finite element method, and the performance of the reduced-order model is evaluated from two aspects of accuracy and rapidity.
first_indexed 2024-03-12T17:50:58Z
format Article
id doaj.art-dcbd0c79bd024374ae1dd4e267f473d8
institution Directory Open Access Journal
issn 2096-3564
2837-0325
language English
last_indexed 2024-03-12T17:50:58Z
publishDate 2023-06-01
publisher China Electrotechnical Society
record_format Article
series CES Transactions on Electrical Machines and Systems
spelling doaj.art-dcbd0c79bd024374ae1dd4e267f473d82023-08-03T08:36:57ZengChina Electrotechnical SocietyCES Transactions on Electrical Machines and Systems2096-35642837-03252023-06-017112913610.30941/CESTEMS.2023.00005IGBT Temperature Field Monitoring Based on Reduced-order ModelZiyu Zhou0 Yi Sui1 Xu Zhang2Chengde Tong3 Ping Zheng4Mingjun Zhu5School of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, ChinaSchool of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, ChinaSchool of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, ChinaSchool of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, ChinaSchool of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, ChinaFlight control department, Xi'an Flight Automatic Control Research Institute, Xi'an, ChinaWith the rapid development of the world economy, IGBT has been widely used in motor drive and electric energy conversion. In order to timely detect the fatigue damage of IGBT, it is necessary to monitor the junction temperature of IGBT. In order to realize the fast calculation of IGBT junction temperature, a finite element method of IGBT temperature field reduction is proposed in this paper. Firstly, the finite element calculation process of IGBT temperature field is introduced and the linear equations of finite element calculation of temperature field are derived. Temperature field data of different working conditions are obtained by finite element simulation to form the sample space. Then the covariance matrix of the sample space is constructed, whose proper orthogonal decomposition and modal extraction are carried out. Reasonable basis vector space is selected to complete the low dimensional expression of temperature vector inside and outside the sample space. Finally, the reduced-order model of temperature field finite element is obtained and solved. The results of the reduced order model are compared with those of the finite element method, and the performance of the reduced-order model is evaluated from two aspects of accuracy and rapidity.https://ieeexplore.ieee.org/document/10018850igbt junction temperatureproper orthogonal decompositionreduced-order model
spellingShingle Ziyu Zhou
Yi Sui
Xu Zhang
Chengde Tong
Ping Zheng
Mingjun Zhu
IGBT Temperature Field Monitoring Based on Reduced-order Model
CES Transactions on Electrical Machines and Systems
igbt junction temperature
proper orthogonal decomposition
reduced-order model
title IGBT Temperature Field Monitoring Based on Reduced-order Model
title_full IGBT Temperature Field Monitoring Based on Reduced-order Model
title_fullStr IGBT Temperature Field Monitoring Based on Reduced-order Model
title_full_unstemmed IGBT Temperature Field Monitoring Based on Reduced-order Model
title_short IGBT Temperature Field Monitoring Based on Reduced-order Model
title_sort igbt temperature field monitoring based on reduced order model
topic igbt junction temperature
proper orthogonal decomposition
reduced-order model
url https://ieeexplore.ieee.org/document/10018850
work_keys_str_mv AT ziyuzhou igbttemperaturefieldmonitoringbasedonreducedordermodel
AT yisui igbttemperaturefieldmonitoringbasedonreducedordermodel
AT xuzhang igbttemperaturefieldmonitoringbasedonreducedordermodel
AT chengdetong igbttemperaturefieldmonitoringbasedonreducedordermodel
AT pingzheng igbttemperaturefieldmonitoringbasedonreducedordermodel
AT mingjunzhu igbttemperaturefieldmonitoringbasedonreducedordermodel