Macro Modeling of V-Shaped Electro-Thermal MEMS Actuator with Human Error Factor

The V-shaped electro-thermal MEMS actuator model, with the human error factor taken into account, is presented in this paper through the cascading ANSYS simulation model and the Fuzzy mathematics calculation model. The Fuzzy mathematics calculation model introduces the human error factor into the ME...

Full description

Bibliographic Details
Main Authors: Dongpeng Zhang, Anjiang Cai, Yulong Zhao, Tengjiang Hu
Format: Article
Language:English
Published: MDPI AG 2021-05-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/12/6/622
Description
Summary:The V-shaped electro-thermal MEMS actuator model, with the human error factor taken into account, is presented in this paper through the cascading ANSYS simulation model and the Fuzzy mathematics calculation model. The Fuzzy mathematics calculation model introduces the human error factor into the MEMS actuator model by using the BP neural network, which effectively reduces the error between ANSYS simulation results and experimental results to less than 1%. Meanwhile, the V-shaped electro-thermal MEMS actuator model, with the human error factor included, will become more accurate as the database of the V-shaped electro-thermal actuator model grows.
ISSN:2072-666X