Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone

Objective. The purpose of the article is to highlight the results of experimental studies, the measurement technique, as well as the design of a laboratory stand for carrying out field tests of a thermoelectric device (TEC) for stopping bleeding by the method of local freezing of the blood flow zone...

Full description

Bibliographic Details
Main Authors: O. V. Evdulov, N. A. Nabiev, R. A.-M. Magomadov, R. G. Mitarov
Format: Article
Language:Russian
Published: Dagestan State Technical University 2022-02-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/996
_version_ 1826560644253483008
author O. V. Evdulov
N. A. Nabiev
R. A.-M. Magomadov
R. G. Mitarov
author_facet O. V. Evdulov
N. A. Nabiev
R. A.-M. Magomadov
R. G. Mitarov
author_sort O. V. Evdulov
collection DOAJ
description Objective. The purpose of the article is to highlight the results of experimental studies, the measurement technique, as well as the design of a laboratory stand for carrying out field tests of a thermoelectric device (TEC) for stopping bleeding by the method of local freezing of the blood flow zone. Method. An experimental stand and a technique for carrying out measurements of a laboratory sample of a TEU for stopping bleeding by the method of local freezing of the blood flow zone are described. The experimental stand is made on the basis of the measuring equipment of the laboratory of semiconductor thermoelectric devices and devices of Daghestan State Technical University. Result. The graphs of the time dependence of the temperature change of the control points of the laboratory sample of TEC for stopping bleeding by the method of local freezing of the blood flow zone at various supply currents of the thermoelectric battery (TEB) were obtained. The control points were cold and hot junctions of TEB, a simulator of a biological object. Conclusion. The data obtained show that with an increase in the area of blood flow, it takes more time to stop it. An increase in the diameter of the hole with blood flow by an average of 1 mm increases the duration of thrombus formation, which stops bleeding by an average of 20 s. During the experiment, it was found that to ensure the efficient operation of the TEU, it is sufficient to use the commercially available TEB brand ICE- 71.
first_indexed 2024-03-12T03:04:34Z
format Article
id doaj.art-dcfc4548234c460998219e0849eb40db
institution Directory Open Access Journal
issn 2073-6185
2542-095X
language Russian
last_indexed 2025-03-14T09:19:33Z
publishDate 2022-02-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj.art-dcfc4548234c460998219e0849eb40db2025-03-02T11:46:08ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2022-02-01484344310.21822/2073-6185-2021-48-4-34-43659Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zoneO. V. Evdulov0N. A. Nabiev1R. A.-M. Magomadov2R. G. Mitarov3Daghestan State Technical UniversityDaghestan State Technical UniversityM.D. Milyionshchikov Grozny State Oil Technical UniversityDaghestan State Technical UniversityObjective. The purpose of the article is to highlight the results of experimental studies, the measurement technique, as well as the design of a laboratory stand for carrying out field tests of a thermoelectric device (TEC) for stopping bleeding by the method of local freezing of the blood flow zone. Method. An experimental stand and a technique for carrying out measurements of a laboratory sample of a TEU for stopping bleeding by the method of local freezing of the blood flow zone are described. The experimental stand is made on the basis of the measuring equipment of the laboratory of semiconductor thermoelectric devices and devices of Daghestan State Technical University. Result. The graphs of the time dependence of the temperature change of the control points of the laboratory sample of TEC for stopping bleeding by the method of local freezing of the blood flow zone at various supply currents of the thermoelectric battery (TEB) were obtained. The control points were cold and hot junctions of TEB, a simulator of a biological object. Conclusion. The data obtained show that with an increase in the area of blood flow, it takes more time to stop it. An increase in the diameter of the hole with blood flow by an average of 1 mm increases the duration of thrombus formation, which stops bleeding by an average of 20 s. During the experiment, it was found that to ensure the efficient operation of the TEU, it is sufficient to use the commercially available TEB brand ICE- 71.https://vestnik.dgtu.ru/jour/article/view/996stopping bleedinglocal freezingthermoelectric devicethermoelectric batteryexperimental standmeasurement techniquetemperaturefield tests
spellingShingle O. V. Evdulov
N. A. Nabiev
R. A.-M. Magomadov
R. G. Mitarov
Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
Вестник Дагестанского государственного технического университета: Технические науки
stopping bleeding
local freezing
thermoelectric device
thermoelectric battery
experimental stand
measurement technique
temperature
field tests
title Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
title_full Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
title_fullStr Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
title_full_unstemmed Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
title_short Experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
title_sort experimental studies of a thermoelectric device for stopping bleeding by the method of local freezing of the blood flow zone
topic stopping bleeding
local freezing
thermoelectric device
thermoelectric battery
experimental stand
measurement technique
temperature
field tests
url https://vestnik.dgtu.ru/jour/article/view/996
work_keys_str_mv AT ovevdulov experimentalstudiesofathermoelectricdeviceforstoppingbleedingbythemethodoflocalfreezingofthebloodflowzone
AT nanabiev experimentalstudiesofathermoelectricdeviceforstoppingbleedingbythemethodoflocalfreezingofthebloodflowzone
AT rammagomadov experimentalstudiesofathermoelectricdeviceforstoppingbleedingbythemethodoflocalfreezingofthebloodflowzone
AT rgmitarov experimentalstudiesofathermoelectricdeviceforstoppingbleedingbythemethodoflocalfreezingofthebloodflowzone