Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
Using electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. T...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf |
_version_ | 1818643788018483200 |
---|---|
author | Nechifor Cristian Borzea Claudia Vlăducă Iulian Mălăel Ion Niculescu Filip |
author_facet | Nechifor Cristian Borzea Claudia Vlăducă Iulian Mălăel Ion Niculescu Filip |
author_sort | Nechifor Cristian |
collection | DOAJ |
description | Using electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. The ingress protection for the electrical part of the valves is ensured by the capsulation assembly, comprising the protection measures applied for preventing the ignition of the surrounding atmosphere. The labyrinth seal through which the gas flow passes is designed so as to confine a potential ignition inside actuator’s flameproof enclosure. Numerical simulations were conducted for determining the combustion behaviour and the optimum width and geometry of the labyrinth canals. |
first_indexed | 2024-12-17T00:04:31Z |
format | Article |
id | doaj.art-dd0231799d7d4f60aea7588435f99ca4 |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-12-17T00:04:31Z |
publishDate | 2020-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-dd0231799d7d4f60aea7588435f99ca42022-12-21T22:11:00ZengEDP SciencesMATEC Web of Conferences2261-236X2020-01-013050002710.1051/matecconf/202030500027matecconf_sesam20_00027Electrically actuated valves for gas compression installations located in potentially explosive atmospheresNechifor Cristian0Borzea Claudia1Vlăducă Iulian2Mălăel Ion3Niculescu Filip4Romanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIUsing electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. The ingress protection for the electrical part of the valves is ensured by the capsulation assembly, comprising the protection measures applied for preventing the ignition of the surrounding atmosphere. The labyrinth seal through which the gas flow passes is designed so as to confine a potential ignition inside actuator’s flameproof enclosure. Numerical simulations were conducted for determining the combustion behaviour and the optimum width and geometry of the labyrinth canals.https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf |
spellingShingle | Nechifor Cristian Borzea Claudia Vlăducă Iulian Mălăel Ion Niculescu Filip Electrically actuated valves for gas compression installations located in potentially explosive atmospheres MATEC Web of Conferences |
title | Electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
title_full | Electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
title_fullStr | Electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
title_full_unstemmed | Electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
title_short | Electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
title_sort | electrically actuated valves for gas compression installations located in potentially explosive atmospheres |
url | https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf |
work_keys_str_mv | AT nechiforcristian electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres AT borzeaclaudia electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres AT vladucaiulian electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres AT malaelion electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres AT niculescufilip electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres |