Electrically actuated valves for gas compression installations located in potentially explosive atmospheres

Using electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. T...

Full description

Bibliographic Details
Main Authors: Nechifor Cristian, Borzea Claudia, Vlăducă Iulian, Mălăel Ion, Niculescu Filip
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf
_version_ 1818643788018483200
author Nechifor Cristian
Borzea Claudia
Vlăducă Iulian
Mălăel Ion
Niculescu Filip
author_facet Nechifor Cristian
Borzea Claudia
Vlăducă Iulian
Mălăel Ion
Niculescu Filip
author_sort Nechifor Cristian
collection DOAJ
description Using electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. The ingress protection for the electrical part of the valves is ensured by the capsulation assembly, comprising the protection measures applied for preventing the ignition of the surrounding atmosphere. The labyrinth seal through which the gas flow passes is designed so as to confine a potential ignition inside actuator’s flameproof enclosure. Numerical simulations were conducted for determining the combustion behaviour and the optimum width and geometry of the labyrinth canals.
first_indexed 2024-12-17T00:04:31Z
format Article
id doaj.art-dd0231799d7d4f60aea7588435f99ca4
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-12-17T00:04:31Z
publishDate 2020-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-dd0231799d7d4f60aea7588435f99ca42022-12-21T22:11:00ZengEDP SciencesMATEC Web of Conferences2261-236X2020-01-013050002710.1051/matecconf/202030500027matecconf_sesam20_00027Electrically actuated valves for gas compression installations located in potentially explosive atmospheresNechifor Cristian0Borzea Claudia1Vlăducă Iulian2Mălăel Ion3Niculescu Filip4Romanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIUsing electric energy in a potentially explosive atmosphere raises several problems that must be solved when designing, manufacturing and during the operation of electric equipment. Their approach requires special attention, considering the multiple technical, economical and labour safety aspects. The ingress protection for the electrical part of the valves is ensured by the capsulation assembly, comprising the protection measures applied for preventing the ignition of the surrounding atmosphere. The labyrinth seal through which the gas flow passes is designed so as to confine a potential ignition inside actuator’s flameproof enclosure. Numerical simulations were conducted for determining the combustion behaviour and the optimum width and geometry of the labyrinth canals.https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf
spellingShingle Nechifor Cristian
Borzea Claudia
Vlăducă Iulian
Mălăel Ion
Niculescu Filip
Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
MATEC Web of Conferences
title Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
title_full Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
title_fullStr Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
title_full_unstemmed Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
title_short Electrically actuated valves for gas compression installations located in potentially explosive atmospheres
title_sort electrically actuated valves for gas compression installations located in potentially explosive atmospheres
url https://www.matec-conferences.org/articles/matecconf/pdf/2020/01/matecconf_sesam20_00027.pdf
work_keys_str_mv AT nechiforcristian electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres
AT borzeaclaudia electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres
AT vladucaiulian electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres
AT malaelion electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres
AT niculescufilip electricallyactuatedvalvesforgascompressioninstallationslocatedinpotentiallyexplosiveatmospheres