Effect of motoring voltage on compression ratio of a free-piston linear generator engine

The need for alternative power sources is crucial because of the increase in global energy demand and stringent emission regulations. The free-piston linear generator engine is one of the main alternatives thanks to its high efficiency, wide operating range and low emissions. However, low compressio...

Full description

Bibliographic Details
Main Authors: Ezrann Z. Zainal, Abdulwehab A. Ibrahim, A. Rashid A. Aziz, Saiful A. Zulkifli
Format: Article
Language:English
Published: Universiti Malaysia Pahang Publishing 2015-06-01
Series:Journal of Mechanical Engineering and Sciences
Subjects:
Online Access:https://journal.ump.edu.my/jmes/article/view/8582
_version_ 1827901416678621184
author Ezrann Z. Zainal
Abdulwehab A. Ibrahim
A. Rashid A. Aziz
Saiful A. Zulkifli
author_facet Ezrann Z. Zainal
Abdulwehab A. Ibrahim
A. Rashid A. Aziz
Saiful A. Zulkifli
author_sort Ezrann Z. Zainal
collection DOAJ
description The need for alternative power sources is crucial because of the increase in global energy demand and stringent emission regulations. The free-piston linear generator engine is one of the main alternatives thanks to its high efficiency, wide operating range and low emissions. However, low compression pressure which produces low power generation is an obstacle to its development. In order to increase compression pressure, further development of the motoring process is required. The study investigated the effect of motoring voltage in compression pressure and compression ratio. Motoring voltages varied from 36 V to 84 V. Higher motoring voltage increased piston speed up to 2 m/s which reduced the air leakage and thus produced a sharper p-V profile and higher compression pressure. An inverse relationship between the compression ratio and compression pressure during motoring was also observed.
first_indexed 2024-03-12T23:44:55Z
format Article
id doaj.art-dd6bcd4b2adc4f2cb0197af102c8d8d5
institution Directory Open Access Journal
issn 2289-4659
2231-8380
language English
last_indexed 2024-03-12T23:44:55Z
publishDate 2015-06-01
publisher Universiti Malaysia Pahang Publishing
record_format Article
series Journal of Mechanical Engineering and Sciences
spelling doaj.art-dd6bcd4b2adc4f2cb0197af102c8d8d52023-07-14T11:55:45ZengUniversiti Malaysia Pahang PublishingJournal of Mechanical Engineering and Sciences2289-46592231-83802015-06-01821393140010.15282/jmes.8.2015.14.0136Effect of motoring voltage on compression ratio of a free-piston linear generator engineEzrann Z. Zainal0Abdulwehab A. Ibrahim1A. Rashid A. Aziz2Saiful A. Zulkifli3Centre for Automotive Research and Energy Management, Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak, Malaysia.2 INTI International University, Persiaran Perdana BBN, 71800 Nilai, Negeri Sembilan, Malaysia.Centre for Automotive Research and Energy Management, Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak, Malaysia.Centre for Automotive Research and Energy Management, Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak, Malaysia.The need for alternative power sources is crucial because of the increase in global energy demand and stringent emission regulations. The free-piston linear generator engine is one of the main alternatives thanks to its high efficiency, wide operating range and low emissions. However, low compression pressure which produces low power generation is an obstacle to its development. In order to increase compression pressure, further development of the motoring process is required. The study investigated the effect of motoring voltage in compression pressure and compression ratio. Motoring voltages varied from 36 V to 84 V. Higher motoring voltage increased piston speed up to 2 m/s which reduced the air leakage and thus produced a sharper p-V profile and higher compression pressure. An inverse relationship between the compression ratio and compression pressure during motoring was also observed.https://journal.ump.edu.my/jmes/article/view/8582free-piston linear generatorcompression ratioin-cylinder pressuremotoring voltage
spellingShingle Ezrann Z. Zainal
Abdulwehab A. Ibrahim
A. Rashid A. Aziz
Saiful A. Zulkifli
Effect of motoring voltage on compression ratio of a free-piston linear generator engine
Journal of Mechanical Engineering and Sciences
free-piston linear generator
compression ratio
in-cylinder pressure
motoring voltage
title Effect of motoring voltage on compression ratio of a free-piston linear generator engine
title_full Effect of motoring voltage on compression ratio of a free-piston linear generator engine
title_fullStr Effect of motoring voltage on compression ratio of a free-piston linear generator engine
title_full_unstemmed Effect of motoring voltage on compression ratio of a free-piston linear generator engine
title_short Effect of motoring voltage on compression ratio of a free-piston linear generator engine
title_sort effect of motoring voltage on compression ratio of a free piston linear generator engine
topic free-piston linear generator
compression ratio
in-cylinder pressure
motoring voltage
url https://journal.ump.edu.my/jmes/article/view/8582
work_keys_str_mv AT ezrannzzainal effectofmotoringvoltageoncompressionratioofafreepistonlineargeneratorengine
AT abdulwehabaibrahim effectofmotoringvoltageoncompressionratioofafreepistonlineargeneratorengine
AT arashidaaziz effectofmotoringvoltageoncompressionratioofafreepistonlineargeneratorengine
AT saifulazulkifli effectofmotoringvoltageoncompressionratioofafreepistonlineargeneratorengine