Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants

The application of autonomous electrical complexes with parallel diesel generator sets based on synchronous generators is considered. The problem of the existence of exchange power fluctuations in such technical systems is described. A mathematical model has been developed that allows conducting res...

Full description

Bibliographic Details
Main Authors: A. E. Savenko, P. S. Savenko
Format: Article
Language:English
Published: Kazan State Power Engineering University 2020-04-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1293
_version_ 1826962332604956672
author A. E. Savenko
P. S. Savenko
author_facet A. E. Savenko
P. S. Savenko
author_sort A. E. Savenko
collection DOAJ
description The application of autonomous electrical complexes with parallel diesel generator sets based on synchronous generators is considered. The problem of the existence of exchange power fluctuations in such technical systems is described. A mathematical model has been developed that allows conducting research of an autonomous electrical complex. It is proposed to implement graphical visualization of the dependence of the amplitude of power exchange fluctuations on time constants in the speed control circuits of diesel generators in the form of configuration maps. An example of using the proposed method for a specific electrical complex is given. The possibility of reducing the amplitude of exchange power fluctuations by reducing the values of time constants of frequency control circuits is justified, which is the basis of a new method for eliminating exchange power fluctuations and makes it possible to improve the method, which is based on changing the transmission coefficients of frequency regulators.
first_indexed 2024-03-12T05:31:15Z
format Article
id doaj.art-ddc56aae8eff43419671ccaadf06c4fe
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2025-02-18T02:03:45Z
publishDate 2020-04-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-ddc56aae8eff43419671ccaadf06c4fe2024-11-26T11:39:39ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032020-04-0122113614410.30724/1998-9903-2020-22-1-136-144654Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plantsA. E. Savenko0P. S. Savenko1Kerch State Maritime Technological UniversityKerch State Maritime Technological UniversityThe application of autonomous electrical complexes with parallel diesel generator sets based on synchronous generators is considered. The problem of the existence of exchange power fluctuations in such technical systems is described. A mathematical model has been developed that allows conducting research of an autonomous electrical complex. It is proposed to implement graphical visualization of the dependence of the amplitude of power exchange fluctuations on time constants in the speed control circuits of diesel generators in the form of configuration maps. An example of using the proposed method for a specific electrical complex is given. The possibility of reducing the amplitude of exchange power fluctuations by reducing the values of time constants of frequency control circuits is justified, which is the basis of a new method for eliminating exchange power fluctuations and makes it possible to improve the method, which is based on changing the transmission coefficients of frequency regulators.https://www.energyret.ru/jour/article/view/1293exchange power fluctuationsparallel operationautonomous electric power complexgenerating setexperimental research
spellingShingle A. E. Savenko
P. S. Savenko
Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
Известия высших учебных заведений: Проблемы энергетики
exchange power fluctuations
parallel operation
autonomous electric power complex
generating set
experimental research
title Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
title_full Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
title_fullStr Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
title_full_unstemmed Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
title_short Influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
title_sort influence of time constants of frequency regulators on the amplitude of power exchange fluctuations in autonomous diesel power plants
topic exchange power fluctuations
parallel operation
autonomous electric power complex
generating set
experimental research
url https://www.energyret.ru/jour/article/view/1293
work_keys_str_mv AT aesavenko influenceoftimeconstantsoffrequencyregulatorsontheamplitudeofpowerexchangefluctuationsinautonomousdieselpowerplants
AT pssavenko influenceoftimeconstantsoffrequencyregulatorsontheamplitudeofpowerexchangefluctuationsinautonomousdieselpowerplants