Intubation strategy in COVID-19 era: An observational study
Background and Aims: Aerosol protection equipment aim at protecting the anaesthesiologist, from aerosol-borne infections, namely, severe acute respiratory syndrome corona virus-2. Methods: We improvised the first-generation intubation box (IB) by increasing its dimensions, including heat and moistur...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2023-01-01
|
Series: | Journal of Minimal Access Surgery |
Subjects: | |
Online Access: | http://www.journalofmas.com/article.asp?issn=0972-9941;year=2023;volume=19;issue=2;spage=234;epage=238;aulast=Sinha |
Summary: | Background and Aims: Aerosol protection equipment aim at protecting the anaesthesiologist, from aerosol-borne infections, namely, severe acute respiratory syndrome corona virus-2.
Methods: We improvised the first-generation intubation box (IB) by increasing its dimensions, including heat and moisture exchanger with filter, suction catheter, and attaching arm sleeves to make a modified intubation box (MIB). The impact of IB, MIB and transparent sheets (TS) on the patient outcomes during airway management was evaluated.
Results: A significant difference in median (interquartile range in minutes) was observed in time to intubate between IB (4 [4–5]); TS (0.5 [0.3–0.5]) and MIB (0.3 [0.3–1.5]): P = 0.004); and airway devices; McCoy (0.5 [0.3–2]), CMac (0.5 [0.3–1.5]): P = 0.004. First-pass success was 100% with the TS, whereas more than three attempts were required with IB 66.7% and 5.2% with MIB. Video laryngoscope was associated with less airway-related adverse events (ARAEs). The need for mask ventilation (and hence possible aerosolisation) was maximum with IB. All the ARAEs resolved uneventfully. No breach of personal protective equipment was observed; none of the health-care professionals involved in patient care developed any symptoms suggestive of COVID-19.
Conclusion: Video laryngoscope is favourable for managing airway in COVID-19 times. In view of the ongoing pandemic and added protection that it offers, it is worthwhile to include the MIB in the armamentarium for managing the airway of patients with COVID-19. |
---|---|