A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging

Background and Objective: Several organization such as AAPM (American Association of Physicist in Medicine), ACR (American College of Radiology), ACMP (American College of Medical Physics) and ESTRO (European Society for Therapeutic Radiology and Oncology) recommended the need for periodic quality c...

Full description

Bibliographic Details
Main Authors: Nickfarjam A (MSc), Shokrani P (PhD), Emami H (MD), Monadi S (MSc), Ganjalikhan Hakemi E (MSc)
Format: Article
Language:fas
Published: Golestan University of Medical Sciences 2010-03-01
Series:مجله دانشگاه علوم پزشکی گرگان
Subjects:
Online Access:http://goums.ac.ir/journal/browse.php?a_code=A-10-1-434&slc_lang=en&sid=1
_version_ 1828310366231199744
author Nickfarjam A (MSc)
Shokrani P (PhD)
Emami H (MD)
Monadi S (MSc)
Ganjalikhan Hakemi E (MSc)
author_facet Nickfarjam A (MSc)
Shokrani P (PhD)
Emami H (MD)
Monadi S (MSc)
Ganjalikhan Hakemi E (MSc)
author_sort Nickfarjam A (MSc)
collection DOAJ
description Background and Objective: Several organization such as AAPM (American Association of Physicist in Medicine), ACR (American College of Radiology), ACMP (American College of Medical Physics) and ESTRO (European Society for Therapeutic Radiology and Oncology) recommended the need for periodic quality control procedure in radiation oncology. One of the best methods for quality control is in vivo dosimetry, while radiotherapy is performed. The aim of this study was to design and optimiz a protocol for the quality control of radiation treatment of patients with head and neck malignancy. Materials and Methods: In this case series study midle line dose was measured in vivo in conjunction with portal imaging in 19 patients that were treated using a Co-60 unit, in August and December 2007. Distribution of entrance and exit dose was determined using two diodes, off axis ratios and portal imaging together with a user code written in MATLAB. User code was applied to convert optical intensity of portal film to optical density. Midline dose was calculated in one centimeter intervals using entrance and exit dose with the Huyskens algorithm method. Results: The midline dose was calculated in 165 points. The mean and standard deviation between measured and prescribed dose was about 4.27±3.61%. In 110 points (66.66%), the deviation was less than 5% (2.27±1.37), in 41 points (24.84%) the mean deviation was between 5 and 10% (6.51±1.2) and in 14 points (8.48%) mean deviation was more than 10% (13.37±2.34). The maximum and minimum deviations were found in center of the field (2.6±1.63) and 5cm away from center of the field (7.24±4.86) respectively. Maximum and minimum deviations correspond to the equivalent field of 14cm2 (5.08±3.53) and 8cm2 (2.95±2.13) respectively. Conclusion: This study showed that using a portal detector in conjunction with two diodes is a simple and accurate method for daily quality control in radiotherapy. The data is acquired in this way can be used for evaluating the accuracy of treatment steps including determination of output of a treatment machine, quality control of a treatment planning system and precision of calculations and patient setup.
first_indexed 2024-04-13T15:42:34Z
format Article
id doaj.art-de027ff985ad427cb72d49977ffa79a8
institution Directory Open Access Journal
issn 1562-4765
2008-4080
language fas
last_indexed 2024-04-13T15:42:34Z
publishDate 2010-03-01
publisher Golestan University of Medical Sciences
record_format Article
series مجله دانشگاه علوم پزشکی گرگان
spelling doaj.art-de027ff985ad427cb72d49977ffa79a82022-12-22T02:41:06ZfasGolestan University of Medical Sciencesمجله دانشگاه علوم پزشکی گرگان1562-47652008-40802010-03-011216369A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imagingNickfarjam A (MSc)0Shokrani P (PhD)1Emami H (MD)2Monadi S (MSc)3Ganjalikhan Hakemi E (MSc)4 Background and Objective: Several organization such as AAPM (American Association of Physicist in Medicine), ACR (American College of Radiology), ACMP (American College of Medical Physics) and ESTRO (European Society for Therapeutic Radiology and Oncology) recommended the need for periodic quality control procedure in radiation oncology. One of the best methods for quality control is in vivo dosimetry, while radiotherapy is performed. The aim of this study was to design and optimiz a protocol for the quality control of radiation treatment of patients with head and neck malignancy. Materials and Methods: In this case series study midle line dose was measured in vivo in conjunction with portal imaging in 19 patients that were treated using a Co-60 unit, in August and December 2007. Distribution of entrance and exit dose was determined using two diodes, off axis ratios and portal imaging together with a user code written in MATLAB. User code was applied to convert optical intensity of portal film to optical density. Midline dose was calculated in one centimeter intervals using entrance and exit dose with the Huyskens algorithm method. Results: The midline dose was calculated in 165 points. The mean and standard deviation between measured and prescribed dose was about 4.27±3.61%. In 110 points (66.66%), the deviation was less than 5% (2.27±1.37), in 41 points (24.84%) the mean deviation was between 5 and 10% (6.51±1.2) and in 14 points (8.48%) mean deviation was more than 10% (13.37±2.34). The maximum and minimum deviations were found in center of the field (2.6±1.63) and 5cm away from center of the field (7.24±4.86) respectively. Maximum and minimum deviations correspond to the equivalent field of 14cm2 (5.08±3.53) and 8cm2 (2.95±2.13) respectively. Conclusion: This study showed that using a portal detector in conjunction with two diodes is a simple and accurate method for daily quality control in radiotherapy. The data is acquired in this way can be used for evaluating the accuracy of treatment steps including determination of output of a treatment machine, quality control of a treatment planning system and precision of calculations and patient setup.http://goums.ac.ir/journal/browse.php?a_code=A-10-1-434&slc_lang=en&sid=1Head and neck cancerQuality control in radiotherapyPortal imagingIn vivo Dosimetry
spellingShingle Nickfarjam A (MSc)
Shokrani P (PhD)
Emami H (MD)
Monadi S (MSc)
Ganjalikhan Hakemi E (MSc)
A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
مجله دانشگاه علوم پزشکی گرگان
Head and neck cancer
Quality control in radiotherapy
Portal imaging
In vivo Dosimetry
title A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
title_full A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
title_fullStr A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
title_full_unstemmed A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
title_short A simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
title_sort simple protocol for in vivo dosimetry in radiotherapy of head and neck tumor using portal imaging
topic Head and neck cancer
Quality control in radiotherapy
Portal imaging
In vivo Dosimetry
url http://goums.ac.ir/journal/browse.php?a_code=A-10-1-434&slc_lang=en&sid=1
work_keys_str_mv AT nickfarjamamsc asimpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT shokranipphd asimpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT emamihmd asimpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT monadismsc asimpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT ganjalikhanhakemiemsc asimpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT nickfarjamamsc simpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT shokranipphd simpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT emamihmd simpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT monadismsc simpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging
AT ganjalikhanhakemiemsc simpleprotocolforinvivodosimetryinradiotherapyofheadandnecktumorusingportalimaging