Development of monitor unit calculation program for integration with radiation therapy information system

Introduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy. Objectives: To develop a monitor unit (MU) calculation program for integratio...

Full description

Bibliographic Details
Main Authors: Damrongsak Tippanya, Ekasit Tharavichitkul, Sumbhat Wanwilairat, Thanit Chaiwiang, Somsak Wanwilairat
Format: Article
Language:English
Published: Chaing Mai University 2016-12-01
Series:Journal of Associated Medical Sciences
Subjects:
Online Access:https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579
_version_ 1811227811488202752
author Damrongsak Tippanya
Ekasit Tharavichitkul
Sumbhat Wanwilairat
Thanit Chaiwiang
Somsak Wanwilairat
author_facet Damrongsak Tippanya
Ekasit Tharavichitkul
Sumbhat Wanwilairat
Thanit Chaiwiang
Somsak Wanwilairat
author_sort Damrongsak Tippanya
collection DOAJ
description Introduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy. Objectives: To develop a monitor unit (MU) calculation program for integration with an in-house radiation therapy information system (RTIS). The developed program was used for 6 MV photon MU calculation in 2D technique teletherapy. Materials and methods: MU calculation program was based on the Clarkson’s integration method and divided into two parts. The first part was for scatter sector radius determination from 2D simulation images. This part was programmed based on JAVA language. The second part was MU calculation using Clarkson’s irregular field method. The latter part was programmed based on Microsoft Visual Foxpro language. Calculated MU was verified by dose measurement following the test cases (1a, 1b, 1c, 2a, 2b and 7) of IAEA TECDOC 1540. After dose difference between the calculation and the measurement was within acceptance criteria, the program was integrated to the RTIS. Results: The scatter sector radius determination program workflow included selecting of the angle between each radius, calibrating of image distance, defining of isocenter, field size edge defining and equivalent square field. The program generated radius distance and exported to a text file. The MU calculation part workflow included input of prescription dose and tumor depth. Following TECDOC 1540, dose different ranging between calculation and measurement was -1.98% to 1.40% for Test case 1a, 1b, 1c, 2a and 2b, and -3.02% to 0.08% for Test case 7. The program was integrated to dosimetry menu in RTIS which could help calculate MU for each field size of each patient and record to patient database. Conclusion: MU calculation computer program was developed, verified and integrated to RTIS. The program was used for 6 MV photon monitor unit calculation in 2D technique irradiation. Journal of Associated Medical Sciences 2017; 50(1): 54-63. Doi: 10.14456/jams.2017.5
first_indexed 2024-04-12T09:48:09Z
format Article
id doaj.art-de05f6720c3e4b098a36b7fd375288aa
institution Directory Open Access Journal
issn 2539-6056
2539-6056
language English
last_indexed 2024-04-12T09:48:09Z
publishDate 2016-12-01
publisher Chaing Mai University
record_format Article
series Journal of Associated Medical Sciences
spelling doaj.art-de05f6720c3e4b098a36b7fd375288aa2022-12-22T03:37:54ZengChaing Mai UniversityJournal of Associated Medical Sciences2539-60562539-60562016-12-01501545473579Development of monitor unit calculation program for integration with radiation therapy information systemDamrongsak Tippanya0Ekasit Tharavichitkul1Sumbhat Wanwilairat2Thanit Chaiwiang3Somsak Wanwilairat41 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, ThailandIntroduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy. Objectives: To develop a monitor unit (MU) calculation program for integration with an in-house radiation therapy information system (RTIS). The developed program was used for 6 MV photon MU calculation in 2D technique teletherapy. Materials and methods: MU calculation program was based on the Clarkson’s integration method and divided into two parts. The first part was for scatter sector radius determination from 2D simulation images. This part was programmed based on JAVA language. The second part was MU calculation using Clarkson’s irregular field method. The latter part was programmed based on Microsoft Visual Foxpro language. Calculated MU was verified by dose measurement following the test cases (1a, 1b, 1c, 2a, 2b and 7) of IAEA TECDOC 1540. After dose difference between the calculation and the measurement was within acceptance criteria, the program was integrated to the RTIS. Results: The scatter sector radius determination program workflow included selecting of the angle between each radius, calibrating of image distance, defining of isocenter, field size edge defining and equivalent square field. The program generated radius distance and exported to a text file. The MU calculation part workflow included input of prescription dose and tumor depth. Following TECDOC 1540, dose different ranging between calculation and measurement was -1.98% to 1.40% for Test case 1a, 1b, 1c, 2a and 2b, and -3.02% to 0.08% for Test case 7. The program was integrated to dosimetry menu in RTIS which could help calculate MU for each field size of each patient and record to patient database. Conclusion: MU calculation computer program was developed, verified and integrated to RTIS. The program was used for 6 MV photon monitor unit calculation in 2D technique irradiation. Journal of Associated Medical Sciences 2017; 50(1): 54-63. Doi: 10.14456/jams.2017.5https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579Clarkson’s integration methodIAEA TECDOC 1540monitor unitprograming.
spellingShingle Damrongsak Tippanya
Ekasit Tharavichitkul
Sumbhat Wanwilairat
Thanit Chaiwiang
Somsak Wanwilairat
Development of monitor unit calculation program for integration with radiation therapy information system
Journal of Associated Medical Sciences
Clarkson’s integration method
IAEA TECDOC 1540
monitor unit
programing.
title Development of monitor unit calculation program for integration with radiation therapy information system
title_full Development of monitor unit calculation program for integration with radiation therapy information system
title_fullStr Development of monitor unit calculation program for integration with radiation therapy information system
title_full_unstemmed Development of monitor unit calculation program for integration with radiation therapy information system
title_short Development of monitor unit calculation program for integration with radiation therapy information system
title_sort development of monitor unit calculation program for integration with radiation therapy information system
topic Clarkson’s integration method
IAEA TECDOC 1540
monitor unit
programing.
url https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579
work_keys_str_mv AT damrongsaktippanya developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem
AT ekasittharavichitkul developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem
AT sumbhatwanwilairat developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem
AT thanitchaiwiang developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem
AT somsakwanwilairat developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem