Development of monitor unit calculation program for integration with radiation therapy information system
Introduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy. Objectives: To develop a monitor unit (MU) calculation program for integratio...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Chaing Mai University
2016-12-01
|
Series: | Journal of Associated Medical Sciences |
Subjects: | |
Online Access: | https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579 |
_version_ | 1811227811488202752 |
---|---|
author | Damrongsak Tippanya Ekasit Tharavichitkul Sumbhat Wanwilairat Thanit Chaiwiang Somsak Wanwilairat |
author_facet | Damrongsak Tippanya Ekasit Tharavichitkul Sumbhat Wanwilairat Thanit Chaiwiang Somsak Wanwilairat |
author_sort | Damrongsak Tippanya |
collection | DOAJ |
description | Introduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy.
Objectives: To develop a monitor unit (MU) calculation program for integration with an in-house radiation therapy information system (RTIS). The developed program was used for 6 MV photon MU calculation in 2D technique teletherapy.
Materials and methods: MU calculation program was based on the Clarkson’s integration method and divided into two parts. The first part was for scatter sector radius determination from 2D simulation images. This part was programmed based on JAVA language. The second part was MU calculation using Clarkson’s irregular field method. The latter part was programmed based on Microsoft Visual Foxpro language. Calculated MU was verified by dose measurement following the test cases (1a, 1b, 1c, 2a, 2b and 7) of IAEA TECDOC 1540. After dose difference between the calculation and the measurement was within acceptance criteria, the program was integrated to the RTIS.
Results: The scatter sector radius determination program workflow included selecting of the angle between each radius, calibrating of image distance, defining of isocenter, field size edge defining and equivalent square field. The program generated radius distance and exported to a text file. The MU calculation part workflow included input of prescription dose and tumor depth. Following TECDOC 1540, dose different ranging between calculation and measurement was -1.98% to 1.40% for Test case 1a, 1b, 1c, 2a and 2b, and -3.02% to 0.08% for Test case 7. The program was integrated to dosimetry menu in RTIS which could help calculate MU for each field size of each patient and record to patient database.
Conclusion: MU calculation computer program was developed, verified and integrated to RTIS. The program was used for 6 MV photon monitor unit calculation in 2D technique irradiation.
Journal of Associated Medical Sciences 2017; 50(1): 54-63. Doi: 10.14456/jams.2017.5 |
first_indexed | 2024-04-12T09:48:09Z |
format | Article |
id | doaj.art-de05f6720c3e4b098a36b7fd375288aa |
institution | Directory Open Access Journal |
issn | 2539-6056 2539-6056 |
language | English |
last_indexed | 2024-04-12T09:48:09Z |
publishDate | 2016-12-01 |
publisher | Chaing Mai University |
record_format | Article |
series | Journal of Associated Medical Sciences |
spelling | doaj.art-de05f6720c3e4b098a36b7fd375288aa2022-12-22T03:37:54ZengChaing Mai UniversityJournal of Associated Medical Sciences2539-60562539-60562016-12-01501545473579Development of monitor unit calculation program for integration with radiation therapy information systemDamrongsak Tippanya0Ekasit Tharavichitkul1Sumbhat Wanwilairat2Thanit Chaiwiang3Somsak Wanwilairat41 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, Thailand1 Division of Radiation Therapy, Radiology Department, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand 2 Thai Petroleum exploration and Production Company, Thailand 3 Datasoft Computer Company Limited, ThailandIntroduction: Monitor unit (MU) calculation is the main process of 2D technique teletherapy planning. Using of monitor unit calculation program will increase the performance and reduce errors of 2D technique teletherapy. Objectives: To develop a monitor unit (MU) calculation program for integration with an in-house radiation therapy information system (RTIS). The developed program was used for 6 MV photon MU calculation in 2D technique teletherapy. Materials and methods: MU calculation program was based on the Clarkson’s integration method and divided into two parts. The first part was for scatter sector radius determination from 2D simulation images. This part was programmed based on JAVA language. The second part was MU calculation using Clarkson’s irregular field method. The latter part was programmed based on Microsoft Visual Foxpro language. Calculated MU was verified by dose measurement following the test cases (1a, 1b, 1c, 2a, 2b and 7) of IAEA TECDOC 1540. After dose difference between the calculation and the measurement was within acceptance criteria, the program was integrated to the RTIS. Results: The scatter sector radius determination program workflow included selecting of the angle between each radius, calibrating of image distance, defining of isocenter, field size edge defining and equivalent square field. The program generated radius distance and exported to a text file. The MU calculation part workflow included input of prescription dose and tumor depth. Following TECDOC 1540, dose different ranging between calculation and measurement was -1.98% to 1.40% for Test case 1a, 1b, 1c, 2a and 2b, and -3.02% to 0.08% for Test case 7. The program was integrated to dosimetry menu in RTIS which could help calculate MU for each field size of each patient and record to patient database. Conclusion: MU calculation computer program was developed, verified and integrated to RTIS. The program was used for 6 MV photon monitor unit calculation in 2D technique irradiation. Journal of Associated Medical Sciences 2017; 50(1): 54-63. Doi: 10.14456/jams.2017.5https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579Clarkson’s integration methodIAEA TECDOC 1540monitor unitprograming. |
spellingShingle | Damrongsak Tippanya Ekasit Tharavichitkul Sumbhat Wanwilairat Thanit Chaiwiang Somsak Wanwilairat Development of monitor unit calculation program for integration with radiation therapy information system Journal of Associated Medical Sciences Clarkson’s integration method IAEA TECDOC 1540 monitor unit programing. |
title | Development of monitor unit calculation program for integration with radiation therapy information system |
title_full | Development of monitor unit calculation program for integration with radiation therapy information system |
title_fullStr | Development of monitor unit calculation program for integration with radiation therapy information system |
title_full_unstemmed | Development of monitor unit calculation program for integration with radiation therapy information system |
title_short | Development of monitor unit calculation program for integration with radiation therapy information system |
title_sort | development of monitor unit calculation program for integration with radiation therapy information system |
topic | Clarkson’s integration method IAEA TECDOC 1540 monitor unit programing. |
url | https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/73579 |
work_keys_str_mv | AT damrongsaktippanya developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem AT ekasittharavichitkul developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem AT sumbhatwanwilairat developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem AT thanitchaiwiang developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem AT somsakwanwilairat developmentofmonitorunitcalculationprogramforintegrationwithradiationtherapyinformationsystem |