Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current
Purposes With the continuous access of distributed generator (DG) in the traditional distribution network, it has brought serious challenges to the distribution network protection configuration. Based on the analysis of the amplitude and phase characteristics of different types of DG fault current i...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Editorial Office of Journal of Taiyuan University of Technology
2024-01-01
|
Series: | Taiyuan Ligong Daxue xuebao |
Subjects: | |
Online Access: | https://tyutjournal.tyut.edu.cn/englishpaper/show-2249.html |
_version_ | 1797208322234908672 |
---|---|
author | Yang YANG Shengwen LI Xiaoqian CHEN Wenping QIN Rui LI Yizhao LIU Yitian CAI |
author_facet | Yang YANG Shengwen LI Xiaoqian CHEN Wenping QIN Rui LI Yizhao LIU Yitian CAI |
author_sort | Yang YANG |
collection | DOAJ |
description | Purposes With the continuous access of distributed generator (DG) in the traditional distribution network, it has brought serious challenges to the distribution network protection configuration. Based on the analysis of the amplitude and phase characteristics of different types of DG fault current in distribution network line fault, this paper proposes a distribution network pilot protection scheme based on the amplitude and phase characteristics of fault sequence current. Methods The scheme uses the amplitude and phase difference characteristics of each sequence fault current at both ends of the line to construct the protection action amount and braking amount respectively. By setting the protection parameters reasonably, the selectivity and sensitivity of complex distribution network protection with different types of DG can be taken into account. Findings The protection scheme setting is simple, real-time adjustment is not required at the operation stage, and the computational power of the protection equipment is low. Finally, the effectiveness of the protection scheme is verified by a simulation example built by RTDS. |
first_indexed | 2024-04-24T09:36:58Z |
format | Article |
id | doaj.art-de0ee8de67dd425b9b589fc955c96d76 |
institution | Directory Open Access Journal |
issn | 1007-9432 |
language | English |
last_indexed | 2024-04-24T09:36:58Z |
publishDate | 2024-01-01 |
publisher | Editorial Office of Journal of Taiyuan University of Technology |
record_format | Article |
series | Taiyuan Ligong Daxue xuebao |
spelling | doaj.art-de0ee8de67dd425b9b589fc955c96d762024-04-15T09:17:22ZengEditorial Office of Journal of Taiyuan University of TechnologyTaiyuan Ligong Daxue xuebao1007-94322024-01-015519310110.16355/j.tyut.1007-9432.202304021007-9432(2024)01-0093-09Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence CurrentYang YANG0Shengwen LI1Xiaoqian CHEN2Wenping QIN3Rui LI4Yizhao LIU5Yitian CAI6Electric Power Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030001, ChinaElectric Power Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030001, ChinaShanxi Key Laboratory of Power System Operation and Control, Taiyuan University of Technology, Taiyuan 030024, ChinaShanxi Key Laboratory of Power System Operation and Control, Taiyuan University of Technology, Taiyuan 030024, ChinaElectric Power Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030001, ChinaElectric Power Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030001, ChinaShanxi Key Laboratory of Power System Operation and Control, Taiyuan University of Technology, Taiyuan 030024, ChinaPurposes With the continuous access of distributed generator (DG) in the traditional distribution network, it has brought serious challenges to the distribution network protection configuration. Based on the analysis of the amplitude and phase characteristics of different types of DG fault current in distribution network line fault, this paper proposes a distribution network pilot protection scheme based on the amplitude and phase characteristics of fault sequence current. Methods The scheme uses the amplitude and phase difference characteristics of each sequence fault current at both ends of the line to construct the protection action amount and braking amount respectively. By setting the protection parameters reasonably, the selectivity and sensitivity of complex distribution network protection with different types of DG can be taken into account. Findings The protection scheme setting is simple, real-time adjustment is not required at the operation stage, and the computational power of the protection equipment is low. Finally, the effectiveness of the protection scheme is verified by a simulation example built by RTDS.https://tyutjournal.tyut.edu.cn/englishpaper/show-2249.htmldistributed generatordistribution networkfault sequence currentamplitude and phase characteristicslongitudinal protection |
spellingShingle | Yang YANG Shengwen LI Xiaoqian CHEN Wenping QIN Rui LI Yizhao LIU Yitian CAI Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current Taiyuan Ligong Daxue xuebao distributed generator distribution network fault sequence current amplitude and phase characteristics longitudinal protection |
title | Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current |
title_full | Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current |
title_fullStr | Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current |
title_full_unstemmed | Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current |
title_short | Longitudinal Protection Scheme for Distribution Network with Distributed Power Based on Amplitude and Phase Characteristics of Fault Sequence Current |
title_sort | longitudinal protection scheme for distribution network with distributed power based on amplitude and phase characteristics of fault sequence current |
topic | distributed generator distribution network fault sequence current amplitude and phase characteristics longitudinal protection |
url | https://tyutjournal.tyut.edu.cn/englishpaper/show-2249.html |
work_keys_str_mv | AT yangyang longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT shengwenli longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT xiaoqianchen longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT wenpingqin longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT ruili longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT yizhaoliu longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent AT yitiancai longitudinalprotectionschemefordistributionnetworkwithdistributedpowerbasedonamplitudeandphasecharacteristicsoffaultsequencecurrent |