Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation

This paper introduces a pressure sensor catheter with two different measurement principles. A Fabry-Perot- Interferometer at the fiber tip is formed by a reflective multilayer membrane of a pressure sensor chip. The cavity provides absolute pressure sensing. 20 millimeter before the fiber tip a Fibe...

Full description

Bibliographic Details
Main Authors: Friedemann Marvin, Voigt Sebastian, Mehner Jan
Format: Article
Language:English
Published: De Gruyter 2022-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2022-1103
_version_ 1797947927454285824
author Friedemann Marvin
Voigt Sebastian
Mehner Jan
author_facet Friedemann Marvin
Voigt Sebastian
Mehner Jan
author_sort Friedemann Marvin
collection DOAJ
description This paper introduces a pressure sensor catheter with two different measurement principles. A Fabry-Perot- Interferometer at the fiber tip is formed by a reflective multilayer membrane of a pressure sensor chip. The cavity provides absolute pressure sensing. 20 millimeter before the fiber tip a Fiber Bragg Grating is integrated for additional temperature sensing. The sensing components are completely coated with a silicone mantle of 2 mm diameter. The signal evaluation is both done with a Fiber Bragg Grating interrogation device. First, mechanical structure aspects of the manufactured fiber-optic hybrid sensor as well as the sensing principle is described. Then, experimental results, including quantification and separation of pressure and temperature sensitivity are presented. Out of these characteristics the possibility for absolute pressure sensing with temperature compensation for the application as a pressure sensor catheter is confirmed.
first_indexed 2024-04-10T21:34:16Z
format Article
id doaj.art-de5314d41e464dcb8d965e5b741968a9
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-04-10T21:34:16Z
publishDate 2022-09-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-de5314d41e464dcb8d965e5b741968a92023-01-19T12:47:02ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042022-09-018240440710.1515/cdbme-2022-1103Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensationFriedemann Marvin0Voigt Sebastian1Mehner Jan2Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, Reichenhainer Strase 70,Chemnitz, GermanyDepartment of Electrical Engineering and Information Technology, Chemnitz University of Technology,Chemnitz, GermanyDepartment of Electrical Engineering and Information Technology, Chemnitz University of Technology,Chemnitz, GermanyThis paper introduces a pressure sensor catheter with two different measurement principles. A Fabry-Perot- Interferometer at the fiber tip is formed by a reflective multilayer membrane of a pressure sensor chip. The cavity provides absolute pressure sensing. 20 millimeter before the fiber tip a Fiber Bragg Grating is integrated for additional temperature sensing. The sensing components are completely coated with a silicone mantle of 2 mm diameter. The signal evaluation is both done with a Fiber Bragg Grating interrogation device. First, mechanical structure aspects of the manufactured fiber-optic hybrid sensor as well as the sensing principle is described. Then, experimental results, including quantification and separation of pressure and temperature sensitivity are presented. Out of these characteristics the possibility for absolute pressure sensing with temperature compensation for the application as a pressure sensor catheter is confirmed.https://doi.org/10.1515/cdbme-2022-1103fiber-optic sensorsfabry-perot-interferometerfiber bragg gratingpressure sensorcathetertemperature compensationinterrogation device
spellingShingle Friedemann Marvin
Voigt Sebastian
Mehner Jan
Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
Current Directions in Biomedical Engineering
fiber-optic sensors
fabry-perot-interferometer
fiber bragg grating
pressure sensor
catheter
temperature compensation
interrogation device
title Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
title_full Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
title_fullStr Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
title_full_unstemmed Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
title_short Pressure sensor catheter based on Fiber Tip Fabry-Pérot-Interferometer and Fiber Bragg Grating for temperature compensation
title_sort pressure sensor catheter based on fiber tip fabry perot interferometer and fiber bragg grating for temperature compensation
topic fiber-optic sensors
fabry-perot-interferometer
fiber bragg grating
pressure sensor
catheter
temperature compensation
interrogation device
url https://doi.org/10.1515/cdbme-2022-1103
work_keys_str_mv AT friedemannmarvin pressuresensorcatheterbasedonfibertipfabryperotinterferometerandfiberbragggratingfortemperaturecompensation
AT voigtsebastian pressuresensorcatheterbasedonfibertipfabryperotinterferometerandfiberbragggratingfortemperaturecompensation
AT mehnerjan pressuresensorcatheterbasedonfibertipfabryperotinterferometerandfiberbragggratingfortemperaturecompensation