Mechanical design of interaction chamber for the ELIADE array at ELI-NP

This paper presents the analysis of the vibration of the interaction chamber (IC), a medium vacuum chamber, that uses linear actuators controlled on the basis of complex signals acquired from the IC and its surrounding space. This research mainly focuses on the kinematic precision assured by the mec...

Full description

Bibliographic Details
Main Authors: Mihaela Violeta Munteanu, Mircea Mihălcică, Călin Itu, Sorin Vlase, Maria Luminita Scutaru
Format: Article
Language:English
Published: AIP Publishing LLC 2020-02-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/1.5129317
_version_ 1828271661422477312
author Mihaela Violeta Munteanu
Mircea Mihălcică
Călin Itu
Sorin Vlase
Maria Luminita Scutaru
author_facet Mihaela Violeta Munteanu
Mircea Mihălcică
Călin Itu
Sorin Vlase
Maria Luminita Scutaru
author_sort Mihaela Violeta Munteanu
collection DOAJ
description This paper presents the analysis of the vibration of the interaction chamber (IC), a medium vacuum chamber, that uses linear actuators controlled on the basis of complex signals acquired from the IC and its surrounding space. This research mainly focuses on the kinematic precision assured by the mechanical system represented by the IC with component parts. The performance obtained by the quadrature acting system for the sample holder will be compared with the error introduced. The software implements two loops: the image acquisition from the digital camera and the detection of the target for the X–Y linear stage. Considering the vibration of the structure, the geometry of the whole system, the kinematics, and the dynamic model are detailed; the hardware’s influence, in conjunction with the corresponding firmware of the tracking installation, is analyzed with regard to positioning precision and dynamics. For the IC, the transmissibility from the ground to the target (which is an important measure for the correct functioning of the system) was determined. As a result, it is necessary to re-design the target’s lever in order to reduce the vibrations during the experiments.
first_indexed 2024-04-13T05:56:20Z
format Article
id doaj.art-de76d608952d4863ab19ae294df77567
institution Directory Open Access Journal
issn 2158-3226
language English
last_indexed 2024-04-13T05:56:20Z
publishDate 2020-02-01
publisher AIP Publishing LLC
record_format Article
series AIP Advances
spelling doaj.art-de76d608952d4863ab19ae294df775672022-12-22T02:59:37ZengAIP Publishing LLCAIP Advances2158-32262020-02-01102025129025129-910.1063/1.5129317Mechanical design of interaction chamber for the ELIADE array at ELI-NPMihaela Violeta Munteanu0Mircea Mihălcică1Călin Itu2Sorin Vlase3Maria Luminita Scutaru4Department of Mechanical Engineering, Faculty of Mechanical Engineering, Transilvania University of Braşov, B-dul Eroilor 29, 500036 Braşov, RomaniaDepartment of Mechanical Engineering, Faculty of Mechanical Engineering, Transilvania University of Braşov, B-dul Eroilor 29, 500036 Braşov, RomaniaDepartment of Mechanical Engineering, Faculty of Mechanical Engineering, Transilvania University of Braşov, B-dul Eroilor 29, 500036 Braşov, RomaniaDepartment of Mechanical Engineering, Faculty of Mechanical Engineering, Transilvania University of Braşov, B-dul Eroilor 29, 500036 Braşov, RomaniaDepartment of Mechanical Engineering, Faculty of Mechanical Engineering, Transilvania University of Braşov, B-dul Eroilor 29, 500036 Braşov, RomaniaThis paper presents the analysis of the vibration of the interaction chamber (IC), a medium vacuum chamber, that uses linear actuators controlled on the basis of complex signals acquired from the IC and its surrounding space. This research mainly focuses on the kinematic precision assured by the mechanical system represented by the IC with component parts. The performance obtained by the quadrature acting system for the sample holder will be compared with the error introduced. The software implements two loops: the image acquisition from the digital camera and the detection of the target for the X–Y linear stage. Considering the vibration of the structure, the geometry of the whole system, the kinematics, and the dynamic model are detailed; the hardware’s influence, in conjunction with the corresponding firmware of the tracking installation, is analyzed with regard to positioning precision and dynamics. For the IC, the transmissibility from the ground to the target (which is an important measure for the correct functioning of the system) was determined. As a result, it is necessary to re-design the target’s lever in order to reduce the vibrations during the experiments.http://dx.doi.org/10.1063/1.5129317
spellingShingle Mihaela Violeta Munteanu
Mircea Mihălcică
Călin Itu
Sorin Vlase
Maria Luminita Scutaru
Mechanical design of interaction chamber for the ELIADE array at ELI-NP
AIP Advances
title Mechanical design of interaction chamber for the ELIADE array at ELI-NP
title_full Mechanical design of interaction chamber for the ELIADE array at ELI-NP
title_fullStr Mechanical design of interaction chamber for the ELIADE array at ELI-NP
title_full_unstemmed Mechanical design of interaction chamber for the ELIADE array at ELI-NP
title_short Mechanical design of interaction chamber for the ELIADE array at ELI-NP
title_sort mechanical design of interaction chamber for the eliade array at eli np
url http://dx.doi.org/10.1063/1.5129317
work_keys_str_mv AT mihaelavioletamunteanu mechanicaldesignofinteractionchamberfortheeliadearrayatelinp
AT mirceamihalcica mechanicaldesignofinteractionchamberfortheeliadearrayatelinp
AT calinitu mechanicaldesignofinteractionchamberfortheeliadearrayatelinp
AT sorinvlase mechanicaldesignofinteractionchamberfortheeliadearrayatelinp
AT marialuminitascutaru mechanicaldesignofinteractionchamberfortheeliadearrayatelinp