X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
The absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamo...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-10-01
|
Series: | Crystals |
Subjects: | |
Online Access: | https://www.mdpi.com/2073-4352/11/10/1258 |
_version_ | 1797514964064272384 |
---|---|
author | Daniele Maria Trucchi Paolo Ascarelli |
author_facet | Daniele Maria Trucchi Paolo Ascarelli |
author_sort | Daniele Maria Trucchi |
collection | DOAJ |
description | The absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamond thin film detector exposed to the energy-selectively-attenuated X-ray beam was used for the reconstruction of the radiation spectrum. The 50 μm thick diamond detector achieves conditions of linear response to the dose rate of the incident radiation (linearity coefficient of 0.997 ± 0.003) for a bias voltage ≥90 V, corresponding to an electric field ≥1.8 × 10<sup>4</sup> V/cm. Once the absorbers method is applied, only the detector signal linearity to dose rate allows reconstructing the source X-ray bremsstrahlung spectrum with sufficiently high accuracy. |
first_indexed | 2024-03-10T06:38:59Z |
format | Article |
id | doaj.art-de8ebbe2804e451482a307aea569a652 |
institution | Directory Open Access Journal |
issn | 2073-4352 |
language | English |
last_indexed | 2024-03-10T06:38:59Z |
publishDate | 2021-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Crystals |
spelling | doaj.art-de8ebbe2804e451482a307aea569a6522023-11-22T17:54:05ZengMDPI AGCrystals2073-43522021-10-011110125810.3390/cryst11101258X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose RateDaniele Maria Trucchi0Paolo Ascarelli1DiaTHEMA Lab, Montelibretti Unit, Istituto di Struttura della Materia ISM-CNR, Via Salaria km 29.3, 00015 Monterotondo Scalo, RM, ItalyDiaTHEMA Lab, Montelibretti Unit, Istituto di Struttura della Materia ISM-CNR, Via Salaria km 29.3, 00015 Monterotondo Scalo, RM, ItalyThe absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamond thin film detector exposed to the energy-selectively-attenuated X-ray beam was used for the reconstruction of the radiation spectrum. The 50 μm thick diamond detector achieves conditions of linear response to the dose rate of the incident radiation (linearity coefficient of 0.997 ± 0.003) for a bias voltage ≥90 V, corresponding to an electric field ≥1.8 × 10<sup>4</sup> V/cm. Once the absorbers method is applied, only the detector signal linearity to dose rate allows reconstructing the source X-ray bremsstrahlung spectrum with sufficiently high accuracy.https://www.mdpi.com/2073-4352/11/10/1258diamondionizing radiation detectionX-ray spectrum reconstruction |
spellingShingle | Daniele Maria Trucchi Paolo Ascarelli X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate Crystals diamond ionizing radiation detection X-ray spectrum reconstruction |
title | X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate |
title_full | X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate |
title_fullStr | X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate |
title_full_unstemmed | X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate |
title_short | X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate |
title_sort | x ray spectrum reconstruction by diamond detectors with linear response to dose rate |
topic | diamond ionizing radiation detection X-ray spectrum reconstruction |
url | https://www.mdpi.com/2073-4352/11/10/1258 |
work_keys_str_mv | AT danielemariatrucchi xrayspectrumreconstructionbydiamonddetectorswithlinearresponsetodoserate AT paoloascarelli xrayspectrumreconstructionbydiamonddetectorswithlinearresponsetodoserate |