X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate

The absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamo...

Full description

Bibliographic Details
Main Authors: Daniele Maria Trucchi, Paolo Ascarelli
Format: Article
Language:English
Published: MDPI AG 2021-10-01
Series:Crystals
Subjects:
Online Access:https://www.mdpi.com/2073-4352/11/10/1258
_version_ 1797514964064272384
author Daniele Maria Trucchi
Paolo Ascarelli
author_facet Daniele Maria Trucchi
Paolo Ascarelli
author_sort Daniele Maria Trucchi
collection DOAJ
description The absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamond thin film detector exposed to the energy-selectively-attenuated X-ray beam was used for the reconstruction of the radiation spectrum. The 50 μm thick diamond detector achieves conditions of linear response to the dose rate of the incident radiation (linearity coefficient of 0.997 ± 0.003) for a bias voltage ≥90 V, corresponding to an electric field ≥1.8 × 10<sup>4</sup> V/cm. Once the absorbers method is applied, only the detector signal linearity to dose rate allows reconstructing the source X-ray bremsstrahlung spectrum with sufficiently high accuracy.
first_indexed 2024-03-10T06:38:59Z
format Article
id doaj.art-de8ebbe2804e451482a307aea569a652
institution Directory Open Access Journal
issn 2073-4352
language English
last_indexed 2024-03-10T06:38:59Z
publishDate 2021-10-01
publisher MDPI AG
record_format Article
series Crystals
spelling doaj.art-de8ebbe2804e451482a307aea569a6522023-11-22T17:54:05ZengMDPI AGCrystals2073-43522021-10-011110125810.3390/cryst11101258X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose RateDaniele Maria Trucchi0Paolo Ascarelli1DiaTHEMA Lab, Montelibretti Unit, Istituto di Struttura della Materia ISM-CNR, Via Salaria km 29.3, 00015 Monterotondo Scalo, RM, ItalyDiaTHEMA Lab, Montelibretti Unit, Istituto di Struttura della Materia ISM-CNR, Via Salaria km 29.3, 00015 Monterotondo Scalo, RM, ItalyThe absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis of the signal provided by a polycrystalline diamond thin film detector exposed to the energy-selectively-attenuated X-ray beam was used for the reconstruction of the radiation spectrum. The 50 μm thick diamond detector achieves conditions of linear response to the dose rate of the incident radiation (linearity coefficient of 0.997 ± 0.003) for a bias voltage ≥90 V, corresponding to an electric field ≥1.8 × 10<sup>4</sup> V/cm. Once the absorbers method is applied, only the detector signal linearity to dose rate allows reconstructing the source X-ray bremsstrahlung spectrum with sufficiently high accuracy.https://www.mdpi.com/2073-4352/11/10/1258diamondionizing radiation detectionX-ray spectrum reconstruction
spellingShingle Daniele Maria Trucchi
Paolo Ascarelli
X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
Crystals
diamond
ionizing radiation detection
X-ray spectrum reconstruction
title X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
title_full X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
title_fullStr X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
title_full_unstemmed X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
title_short X-ray Spectrum Reconstruction by Diamond Detectors with Linear Response to Dose Rate
title_sort x ray spectrum reconstruction by diamond detectors with linear response to dose rate
topic diamond
ionizing radiation detection
X-ray spectrum reconstruction
url https://www.mdpi.com/2073-4352/11/10/1258
work_keys_str_mv AT danielemariatrucchi xrayspectrumreconstructionbydiamonddetectorswithlinearresponsetodoserate
AT paoloascarelli xrayspectrumreconstructionbydiamonddetectorswithlinearresponsetodoserate