Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator
For the problem that industrial computer is easy to crash after a certain number of years in switchover control system without blowing-out of mine main ventilator, the paper proposed the solution of connecting sensor to the switch, and using multiple industrial computers to read data at the same tim...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2012-11-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/id/8727 |
_version_ | 1827988180445429760 |
---|---|
author | MENG Lin-shan MA Xiao-ping LI Quan-bao |
author_facet | MENG Lin-shan MA Xiao-ping LI Quan-bao |
author_sort | MENG Lin-shan |
collection | DOAJ |
description | For the problem that industrial computer is easy to crash after a certain number of years in switchover control system without blowing-out of mine main ventilator, the paper proposed the solution of connecting sensor to the switch, and using multiple industrial computers to read data at the same time. For the problem that RS485 signal output by temperature logging devices and electrical parameters acquisition modules cannot directly access the switch, the paper proposed two improvement schemes, namely adding serial servers or RS485 modules of PLC. It analyzed advantages and disadvantages of the schemes and ultimately chose the scheme of adding RS485 module of PLC. The practical application shows that the improved system runs well and achieves the desired effect. |
first_indexed | 2024-04-09T23:58:27Z |
format | Article |
id | doaj.art-de974ae9fa5f4f848ea6ffb67a444cec |
institution | Directory Open Access Journal |
issn | 1671-251X |
language | zho |
last_indexed | 2024-04-09T23:58:27Z |
publishDate | 2012-11-01 |
publisher | Editorial Department of Industry and Mine Automation |
record_format | Article |
series | Gong-kuang zidonghua |
spelling | doaj.art-de974ae9fa5f4f848ea6ffb67a444cec2023-03-17T01:59:41ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2012-11-013811910Improvement Scheme of Switchover Control System without Blowing-out of Mine Main VentilatorMENG Lin-shanMA Xiao-pingLI Quan-baoFor the problem that industrial computer is easy to crash after a certain number of years in switchover control system without blowing-out of mine main ventilator, the paper proposed the solution of connecting sensor to the switch, and using multiple industrial computers to read data at the same time. For the problem that RS485 signal output by temperature logging devices and electrical parameters acquisition modules cannot directly access the switch, the paper proposed two improvement schemes, namely adding serial servers or RS485 modules of PLC. It analyzed advantages and disadvantages of the schemes and ultimately chose the scheme of adding RS485 module of PLC. The practical application shows that the improved system runs well and achieves the desired effect.http://www.gkzdh.cn/article/id/8727mine ventilator, switchover without blowing-out, serial server, plc |
spellingShingle | MENG Lin-shan MA Xiao-ping LI Quan-bao Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator Gong-kuang zidonghua mine ventilator, switchover without blowing-out, serial server, plc |
title | Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator |
title_full | Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator |
title_fullStr | Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator |
title_full_unstemmed | Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator |
title_short | Improvement Scheme of Switchover Control System without Blowing-out of Mine Main Ventilator |
title_sort | improvement scheme of switchover control system without blowing out of mine main ventilator |
topic | mine ventilator, switchover without blowing-out, serial server, plc |
url | http://www.gkzdh.cn/article/id/8727 |
work_keys_str_mv | AT menglinshan improvementschemeofswitchovercontrolsystemwithoutblowingoutofminemainventilator AT maxiaoping improvementschemeofswitchovercontrolsystemwithoutblowingoutofminemainventilator AT liquanbao improvementschemeofswitchovercontrolsystemwithoutblowingoutofminemainventilator |