Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station
Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity was conducted when heat removing from an oil tank of a power transformer of combined heat and power station (CHP). The power transformer cooling system by the closed biphasic thermosyphon w...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/matecconf/20179201058 |
_version_ | 1818343956830748672 |
---|---|
author | Nurpeiis Atlant Mamontov Gennady Valieva Lylya |
author_facet | Nurpeiis Atlant Mamontov Gennady Valieva Lylya |
author_sort | Nurpeiis Atlant |
collection | DOAJ |
description | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity was conducted when heat removing from an oil tank of a power transformer of combined heat and power station (CHP). The power transformer cooling system by the closed biphasic thermosyphon was proposed. The mathematical modeling of heat transfer and phase transitions of coolant in the thermosyphon was performed. The problem of heat transfer is formulated in dimensionless variables “velocity vorticity vector – current function – temperature” and solved by finite difference method. As a result of numerical simulation it is found that an increase in the vapor channel length from 0.15m to 1m leads to increasing the temperature difference by 3.5 K. |
first_indexed | 2024-12-13T16:38:50Z |
format | Article |
id | doaj.art-deebf5eb3b194c58a03a87f6d1efdafb |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-12-13T16:38:50Z |
publishDate | 2017-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-deebf5eb3b194c58a03a87f6d1efdafb2022-12-21T23:38:20ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-01920105810.1051/matecconf/20179201058matecconf_tibet2017_01058Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power stationNurpeiis Atlant0Mamontov Gennady1Valieva Lylya2National Research Tomsk Polytechnic UniversityNational Research Tomsk Polytechnic UniversityNational Research Tomsk Polytechnic UniversityNumerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity was conducted when heat removing from an oil tank of a power transformer of combined heat and power station (CHP). The power transformer cooling system by the closed biphasic thermosyphon was proposed. The mathematical modeling of heat transfer and phase transitions of coolant in the thermosyphon was performed. The problem of heat transfer is formulated in dimensionless variables “velocity vorticity vector – current function – temperature” and solved by finite difference method. As a result of numerical simulation it is found that an increase in the vapor channel length from 0.15m to 1m leads to increasing the temperature difference by 3.5 K.http://dx.doi.org/10.1051/matecconf/20179201058 |
spellingShingle | Nurpeiis Atlant Mamontov Gennady Valieva Lylya Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station MATEC Web of Conferences |
title | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
title_full | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
title_fullStr | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
title_full_unstemmed | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
title_short | Numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
title_sort | numerical analyses of the effect of a biphasic thermosyphon vapor channel sizes on the heat transfer intensity when heat removing from a power transformer of combined heat and power station |
url | http://dx.doi.org/10.1051/matecconf/20179201058 |
work_keys_str_mv | AT nurpeiisatlant numericalanalysesoftheeffectofabiphasicthermosyphonvaporchannelsizesontheheattransferintensitywhenheatremovingfromapowertransformerofcombinedheatandpowerstation AT mamontovgennady numericalanalysesoftheeffectofabiphasicthermosyphonvaporchannelsizesontheheattransferintensitywhenheatremovingfromapowertransformerofcombinedheatandpowerstation AT valievalylya numericalanalysesoftheeffectofabiphasicthermosyphonvaporchannelsizesontheheattransferintensitywhenheatremovingfromapowertransformerofcombinedheatandpowerstation |