A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden

The building sector accounts for a third of the total energy use in Sweden, and district heating provides half of the heating needs. The peak demand loads within a district heating network occur both regularly and irregularly and impose a burden on the energy company to fulfill the demand, often by...

Full description

Bibliographic Details
Main Authors: Abolfazl Hayati, Jan Akander, Martin Eriksson
Format: Article
Language:English
Published: MDPI AG 2022-07-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/7/1007
_version_ 1797433767171719168
author Abolfazl Hayati
Jan Akander
Martin Eriksson
author_facet Abolfazl Hayati
Jan Akander
Martin Eriksson
author_sort Abolfazl Hayati
collection DOAJ
description The building sector accounts for a third of the total energy use in Sweden, and district heating provides half of the heating needs. The peak demand loads within a district heating network occur both regularly and irregularly and impose a burden on the energy company to fulfill the demand, often by using more expensive and less environmentally friendly resources (e.g., fossil fuels) instead of the waste heat from industry or biofuels. Heat storage during hours of less demand and prior to colder periods can be used for load management and sustainable planning of energy supply, as well as reduction of total greenhouse gas emissions. Thus, heat supply to the building can be lowered temporarily during the peak power period to utilize the stored thermal energy within the building thermal inertia. The use of indoor temperature decay and the delivery of heating power to a multifamily building are studied here, and heating storage capacity and thermal inertia are calculated. During the performed decay test, the energy supply was estimated to be reduced by 61% for 5 h, which resulted in only a 0.3 °C temperature decay. Therefore, the suggested method can shave eventual peaks in supplied heat with minimal influence on the thermal comfort.
first_indexed 2024-03-09T10:21:42Z
format Article
id doaj.art-df1aa57a5f6e4f6bae5aed43bf4c39f5
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T10:21:42Z
publishDate 2022-07-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-df1aa57a5f6e4f6bae5aed43bf4c39f52023-12-01T21:58:39ZengMDPI AGBuildings2075-53092022-07-01127100710.3390/buildings12071007A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-SwedenAbolfazl Hayati0Jan Akander1Martin Eriksson2Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, SwedenDepartment of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, SwedenDepartment of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, SwedenThe building sector accounts for a third of the total energy use in Sweden, and district heating provides half of the heating needs. The peak demand loads within a district heating network occur both regularly and irregularly and impose a burden on the energy company to fulfill the demand, often by using more expensive and less environmentally friendly resources (e.g., fossil fuels) instead of the waste heat from industry or biofuels. Heat storage during hours of less demand and prior to colder periods can be used for load management and sustainable planning of energy supply, as well as reduction of total greenhouse gas emissions. Thus, heat supply to the building can be lowered temporarily during the peak power period to utilize the stored thermal energy within the building thermal inertia. The use of indoor temperature decay and the delivery of heating power to a multifamily building are studied here, and heating storage capacity and thermal inertia are calculated. During the performed decay test, the energy supply was estimated to be reduced by 61% for 5 h, which resulted in only a 0.3 °C temperature decay. Therefore, the suggested method can shave eventual peaks in supplied heat with minimal influence on the thermal comfort.https://www.mdpi.com/2075-5309/12/7/1007district heatingload managementpeak shavingthermal storageenergy signaturethermal inertia of buildings
spellingShingle Abolfazl Hayati
Jan Akander
Martin Eriksson
A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
Buildings
district heating
load management
peak shaving
thermal storage
energy signature
thermal inertia of buildings
title A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
title_full A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
title_fullStr A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
title_full_unstemmed A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
title_short A Case Study of Mapping the Heating Storage Capacity in a Multifamily Building within a District Heating Network in Mid-Sweden
title_sort case study of mapping the heating storage capacity in a multifamily building within a district heating network in mid sweden
topic district heating
load management
peak shaving
thermal storage
energy signature
thermal inertia of buildings
url https://www.mdpi.com/2075-5309/12/7/1007
work_keys_str_mv AT abolfazlhayati acasestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden
AT janakander acasestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden
AT martineriksson acasestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden
AT abolfazlhayati casestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden
AT janakander casestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden
AT martineriksson casestudyofmappingtheheatingstoragecapacityinamultifamilybuildingwithinadistrictheatingnetworkinmidsweden