Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility

Purpose. To study approaches to the quantitative assessment of breast arterial calcification (BAC) – a new surrogate marker of high cardiovascular risk in women, to determine the most detailed way to quantify BAC and to assess the reproducibility of these parameters.Material and methods. Mammograms...

Full description

Bibliographic Details
Main Authors: E. V. Bochkareva, E. K. Butina, N. Kh. Bayramkulova, O. A. Abdalova, V. A. Kutsenko, O. M. Drapkina
Format: Article
Language:English
Published: Столичная издательская компания 2021-11-01
Series:Рациональная фармакотерапия в кардиологии
Subjects:
Online Access:https://www.rpcardio.online/jour/article/view/2578
_version_ 1797232121041911808
author E. V. Bochkareva
E. K. Butina
N. Kh. Bayramkulova
O. A. Abdalova
V. A. Kutsenko
O. M. Drapkina
author_facet E. V. Bochkareva
E. K. Butina
N. Kh. Bayramkulova
O. A. Abdalova
V. A. Kutsenko
O. M. Drapkina
author_sort E. V. Bochkareva
collection DOAJ
description Purpose. To study approaches to the quantitative assessment of breast arterial calcification (BAC) – a new surrogate marker of high cardiovascular risk in women, to determine the most detailed way to quantify BAC and to assess the reproducibility of these parameters.Material and methods. Mammograms of 1,078 women were analyzed for the presence of BAC. The intraoperator reproducibility of the assessment of the severity of BAC using a 12-point scale (Margolies L et al., 2016) was studied by analyzing 20 mammograms by the same operator twice with an interval of at least 2 weeks. Inter-operator reproducibility was studied by analyzing 99 mammograms by two independent operators.Results. When assessing the intraoperative reproducibility of the total score for each mammary gland, the exact coincidence of the results was noted in 70% (95% confidence interval [CI] 53.5-83.4), in cases of difference of no more than 1 point – in 27.5% (95%CI 14.6-43.9), only in 1 case the difference in assessments was 2 points. No systematic error was found between the two measurements (p=1.0), the correlation coefficient was rs=0.973. The assessment of inter-operator reproducibility showed that the exact coincidence of indicators was present in 48.5% (95%CI 41.3-55.7), in 91.4% (95% CI 86.6-94.9) cases, the total score for each the mammary gland differed by no more than 1 point. There was no systematic error between the measurements of the two experts (p=0.438), the correlation coefficient was rs=0.942.Conclusion. A good intraoperator and interoperator reproducibility of indicators of the severity of BAC on a 12-point scale has been shown, which makes it possible to recommend it for use in science and practice.
first_indexed 2024-03-08T14:00:33Z
format Article
id doaj.art-df3d8f17c3734733b2dc427a54433412
institution Directory Open Access Journal
issn 1819-6446
2225-3653
language English
last_indexed 2024-04-24T15:55:14Z
publishDate 2021-11-01
publisher Столичная издательская компания
record_format Article
series Рациональная фармакотерапия в кардиологии
spelling doaj.art-df3d8f17c3734733b2dc427a544334122024-04-01T07:43:41ZengСтоличная издательская компанияРациональная фармакотерапия в кардиологии1819-64462225-36532021-11-0117568869510.20996/1819-6446-2021-10-071943Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator ReproducibilityE. V. Bochkareva0E. K. Butina1N. Kh. Bayramkulova2O. A. Abdalova3V. A. Kutsenko4O. M. Drapkina5National Medical Research Center for Therapy and Preventive MedicineNational Medical Research Center for Therapy and Preventive MedicineNational Medical Research Center for Therapy and Preventive MedicineNational Medical Research Center for Therapy and Preventive MedicineNational Medical Research Center for Therapy and Preventive MedicineNational Medical Research Center for Therapy and Preventive MedicinePurpose. To study approaches to the quantitative assessment of breast arterial calcification (BAC) – a new surrogate marker of high cardiovascular risk in women, to determine the most detailed way to quantify BAC and to assess the reproducibility of these parameters.Material and methods. Mammograms of 1,078 women were analyzed for the presence of BAC. The intraoperator reproducibility of the assessment of the severity of BAC using a 12-point scale (Margolies L et al., 2016) was studied by analyzing 20 mammograms by the same operator twice with an interval of at least 2 weeks. Inter-operator reproducibility was studied by analyzing 99 mammograms by two independent operators.Results. When assessing the intraoperative reproducibility of the total score for each mammary gland, the exact coincidence of the results was noted in 70% (95% confidence interval [CI] 53.5-83.4), in cases of difference of no more than 1 point – in 27.5% (95%CI 14.6-43.9), only in 1 case the difference in assessments was 2 points. No systematic error was found between the two measurements (p=1.0), the correlation coefficient was rs=0.973. The assessment of inter-operator reproducibility showed that the exact coincidence of indicators was present in 48.5% (95%CI 41.3-55.7), in 91.4% (95% CI 86.6-94.9) cases, the total score for each the mammary gland differed by no more than 1 point. There was no systematic error between the measurements of the two experts (p=0.438), the correlation coefficient was rs=0.942.Conclusion. A good intraoperator and interoperator reproducibility of indicators of the severity of BAC on a 12-point scale has been shown, which makes it possible to recommend it for use in science and practice.https://www.rpcardio.online/jour/article/view/2578breast arterial calcificationmammogramsreproducibility
spellingShingle E. V. Bochkareva
E. K. Butina
N. Kh. Bayramkulova
O. A. Abdalova
V. A. Kutsenko
O. M. Drapkina
Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
Рациональная фармакотерапия в кардиологии
breast arterial calcification
mammograms
reproducibility
title Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
title_full Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
title_fullStr Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
title_full_unstemmed Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
title_short Assessment of the Severity of Breast Artery Calcification on a Mammogram: Intraoperator and Interoperator Reproducibility
title_sort assessment of the severity of breast artery calcification on a mammogram intraoperator and interoperator reproducibility
topic breast arterial calcification
mammograms
reproducibility
url https://www.rpcardio.online/jour/article/view/2578
work_keys_str_mv AT evbochkareva assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility
AT ekbutina assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility
AT nkhbayramkulova assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility
AT oaabdalova assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility
AT vakutsenko assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility
AT omdrapkina assessmentoftheseverityofbreastarterycalcificationonamammogramintraoperatorandinteroperatorreproducibility