Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment

For problems that high temperature caused by bad contact of isolator of mine-used high-voltage distribution equipment usually leads to faults and the faults are hardly detected, a design scheme of on-line monitoring system for temperature of isolator contact of mine-used high-voltage distribution eq...

Full description

Bibliographic Details
Main Authors: WU Jun-feng, SONG Jian-cheng, QU Bing-ni
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2011-09-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/id/5410
_version_ 1797868530189729792
author WU Jun-feng
SONG Jian-cheng
QU Bing-ni
author_facet WU Jun-feng
SONG Jian-cheng
QU Bing-ni
author_sort WU Jun-feng
collection DOAJ
description For problems that high temperature caused by bad contact of isolator of mine-used high-voltage distribution equipment usually leads to faults and the faults are hardly detected, a design scheme of on-line monitoring system for temperature of isolator contact of mine-used high-voltage distribution equipment was put forward and software designs of lower computer program and on-line monitoring program based on LabVIEW of the system were introduced emphatically. The test result showed that the system can monitor temperature of isolator contact of mine-used high-voltage distribution equipment real-timely and remotely with error less than 1 ℃, which can meet requirement of actual project. Besides, the system has functions of fault diagnosis and early warning according to monitored temperature signal.
first_indexed 2024-04-09T23:57:21Z
format Article
id doaj.art-df57dd2a83034bb0984e8b8bdadbe12a
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-09T23:57:21Z
publishDate 2011-09-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-df57dd2a83034bb0984e8b8bdadbe12a2023-03-17T02:41:28ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2011-09-0137969Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution EquipmentWU Jun-fengSONG Jian-chengQU Bing-niFor problems that high temperature caused by bad contact of isolator of mine-used high-voltage distribution equipment usually leads to faults and the faults are hardly detected, a design scheme of on-line monitoring system for temperature of isolator contact of mine-used high-voltage distribution equipment was put forward and software designs of lower computer program and on-line monitoring program based on LabVIEW of the system were introduced emphatically. The test result showed that the system can monitor temperature of isolator contact of mine-used high-voltage distribution equipment real-timely and remotely with error less than 1 ℃, which can meet requirement of actual project. Besides, the system has functions of fault diagnosis and early warning according to monitored temperature signal.http://www.gkzdh.cn/article/id/5410mine-used high-voltage distribution equipment, isolator contact, temperature monitoring, fault diagnosis, early warning for fault, virtual instrument
spellingShingle WU Jun-feng
SONG Jian-cheng
QU Bing-ni
Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
Gong-kuang zidonghua
mine-used high-voltage distribution equipment, isolator contact, temperature monitoring, fault diagnosis, early warning for fault, virtual instrument
title Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
title_full Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
title_fullStr Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
title_full_unstemmed Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
title_short Design of On-line Monitoring System for Temperature of Isolator Contacts of Mine-used High-voltage Distribution Equipment
title_sort design of on line monitoring system for temperature of isolator contacts of mine used high voltage distribution equipment
topic mine-used high-voltage distribution equipment, isolator contact, temperature monitoring, fault diagnosis, early warning for fault, virtual instrument
url http://www.gkzdh.cn/article/id/5410
work_keys_str_mv AT wujunfeng designofonlinemonitoringsystemfortemperatureofisolatorcontactsofmineusedhighvoltagedistributionequipment
AT songjiancheng designofonlinemonitoringsystemfortemperatureofisolatorcontactsofmineusedhighvoltagedistributionequipment
AT qubingni designofonlinemonitoringsystemfortemperatureofisolatorcontactsofmineusedhighvoltagedistributionequipment