Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss

<i>Introduction</i>: a primary goal in revision total knee arthroplasty is to recreate and restore near-normal knee biomechanics by reapproximating the native anatomy. Tibial bone loss poses a challenge for surgeons. Bone cement, bone allograft, screws-in-cement, metaphyseal sleeves or c...

Full description

Bibliographic Details
Main Authors: Max Jiganti, Nicholas Tedesco
Format: Article
Language:English
Published: MDPI AG 2023-01-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/59/1/162
_version_ 1797438894712553472
author Max Jiganti
Nicholas Tedesco
author_facet Max Jiganti
Nicholas Tedesco
author_sort Max Jiganti
collection DOAJ
description <i>Introduction</i>: a primary goal in revision total knee arthroplasty is to recreate and restore near-normal knee biomechanics by reapproximating the native anatomy. Tibial bone loss poses a challenge for surgeons. Bone cement, bone allograft, screws-in-cement, metaphyseal sleeves or cones, and metallic augments are some options for addressing bony deficiency, with endoprosthetic proximal tibia replacement a consideration for the most severe cases. <i>Case Description</i>: we present a case for the novel use of threaded Steinmann pins augmented with cement to reconstruct a massive tibial metaphyseal cortical defect during revision knee arthroplasty. A 76-year-old male presented with an infected primary total knee arthroplasty using MSIS (Musculoskeletal Infection Society) criteria and underwent a standard two-stage revision total knee arthroplasty once the knee was confirmed sterile. Intraoperatively, significant posteromedial and metaphyseal tibial bone loss was identified. In order to avoid proximal tibial replacement and the extensor mechanism complications seen with these, coupled with obligate gastrocnemius flap, a metaphyseal cone was utilized in the proximal tibia with four vertical threaded Steinmann pins spaced approximately 1 cm apart at its periphery, subsequently cut flush with the level of the cone after cementation to recreate the tibial cortex. The patient’s function and range of motion continue to improve with no evidence of structural complication at 2.5 years of follow-up. <i>Discussion</i>: the implementation of threaded Steinmann pins was utilized in this case to stabilize a cemented metaphyseal cone in the revision of an infected total knee with significant tibial bone loss. The threaded property may help prevent migration of these pins in comparison to smooth pins. Creation of a stable platform in a revision total knee arthroplasty poses a substantial challenge in the context of significant bone loss, and our case depicts a good short-term outcome and another option for surgeons to consider before moving toward endoprostheses.
first_indexed 2024-03-09T11:44:54Z
format Article
id doaj.art-df631ef7d5624026b7091de96025c10f
institution Directory Open Access Journal
issn 1010-660X
1648-9144
language English
last_indexed 2024-03-09T11:44:54Z
publishDate 2023-01-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj.art-df631ef7d5624026b7091de96025c10f2023-11-30T23:25:16ZengMDPI AGMedicina1010-660X1648-91442023-01-0159116210.3390/medicina59010162Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone LossMax Jiganti0Nicholas Tedesco1Good Samaritan Regional Medical Center, Corvallis, OR 97330, USAGood Samaritan Regional Medical Center, Corvallis, OR 97330, USA<i>Introduction</i>: a primary goal in revision total knee arthroplasty is to recreate and restore near-normal knee biomechanics by reapproximating the native anatomy. Tibial bone loss poses a challenge for surgeons. Bone cement, bone allograft, screws-in-cement, metaphyseal sleeves or cones, and metallic augments are some options for addressing bony deficiency, with endoprosthetic proximal tibia replacement a consideration for the most severe cases. <i>Case Description</i>: we present a case for the novel use of threaded Steinmann pins augmented with cement to reconstruct a massive tibial metaphyseal cortical defect during revision knee arthroplasty. A 76-year-old male presented with an infected primary total knee arthroplasty using MSIS (Musculoskeletal Infection Society) criteria and underwent a standard two-stage revision total knee arthroplasty once the knee was confirmed sterile. Intraoperatively, significant posteromedial and metaphyseal tibial bone loss was identified. In order to avoid proximal tibial replacement and the extensor mechanism complications seen with these, coupled with obligate gastrocnemius flap, a metaphyseal cone was utilized in the proximal tibia with four vertical threaded Steinmann pins spaced approximately 1 cm apart at its periphery, subsequently cut flush with the level of the cone after cementation to recreate the tibial cortex. The patient’s function and range of motion continue to improve with no evidence of structural complication at 2.5 years of follow-up. <i>Discussion</i>: the implementation of threaded Steinmann pins was utilized in this case to stabilize a cemented metaphyseal cone in the revision of an infected total knee with significant tibial bone loss. The threaded property may help prevent migration of these pins in comparison to smooth pins. Creation of a stable platform in a revision total knee arthroplasty poses a substantial challenge in the context of significant bone loss, and our case depicts a good short-term outcome and another option for surgeons to consider before moving toward endoprostheses.https://www.mdpi.com/1648-9144/59/1/162revision total knee arthroplastymetaphyseal conecemented stemtibial bone lossSteinmann pin
spellingShingle Max Jiganti
Nicholas Tedesco
Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
Medicina
revision total knee arthroplasty
metaphyseal cone
cemented stem
tibial bone loss
Steinmann pin
title Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
title_full Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
title_fullStr Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
title_full_unstemmed Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
title_short Revision Total Knee Arthroplasty Utilizing Threaded Pins in Cement for Tibial Bone Loss
title_sort revision total knee arthroplasty utilizing threaded pins in cement for tibial bone loss
topic revision total knee arthroplasty
metaphyseal cone
cemented stem
tibial bone loss
Steinmann pin
url https://www.mdpi.com/1648-9144/59/1/162
work_keys_str_mv AT maxjiganti revisiontotalkneearthroplastyutilizingthreadedpinsincementfortibialboneloss
AT nicholastedesco revisiontotalkneearthroplastyutilizingthreadedpinsincementfortibialboneloss