Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis

A novel field olfactometer, Scentroid SM110 (IDES Canada Inc., 2012), based on a new technology, has been tested in comparison with another portable olfactometer, Nasal Ranger (St. Croix Sensory Inc., 2003). Responses of both devices during a measurement campaign were compared with odour predicted v...

Full description

Bibliographic Details
Main Authors: M. Benzo, A. Mantovani, A. Pittarello
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2012-09-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/6957
_version_ 1818923035233615872
author M. Benzo
A. Mantovani
A. Pittarello
author_facet M. Benzo
A. Mantovani
A. Pittarello
author_sort M. Benzo
collection DOAJ
description A novel field olfactometer, Scentroid SM110 (IDES Canada Inc., 2012), based on a new technology, has been tested in comparison with another portable olfactometer, Nasal Ranger (St. Croix Sensory Inc., 2003). Responses of both devices during a measurement campaign were compared with odour predicted values by a dispersion model and with chemical data of emission marker’s analysis. The measurement test was performed in an anaerobic digestion plant located near Vicenza (Italy) and one typical odour source was a biofilter with an emission of 350 ouE/m3. The objective of this study is to compare different techniques (field olfactometry, marker’s analysis, dispersion model) for assessing the concentration of odour in ambient air. The analysis of results shows a clear and measurable influence of background odour in ambient air, resulting in higher odour levels when measured using field olfactometry than is predicted using chemical analysis or dispersion modeling. Furthermore, a good agreement was found between chemical data and predicted values from CALPUFF dispersion model.
first_indexed 2024-12-20T02:03:02Z
format Article
id doaj.art-df96aa770ef7489b8e46cab8a83fe4a2
institution Directory Open Access Journal
issn 2283-9216
language English
last_indexed 2024-12-20T02:03:02Z
publishDate 2012-09-01
publisher AIDIC Servizi S.r.l.
record_format Article
series Chemical Engineering Transactions
spelling doaj.art-df96aa770ef7489b8e46cab8a83fe4a22022-12-21T19:57:16ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162012-09-013010.3303/CET1230018Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical AnalysisM. BenzoA. MantovaniA. PittarelloA novel field olfactometer, Scentroid SM110 (IDES Canada Inc., 2012), based on a new technology, has been tested in comparison with another portable olfactometer, Nasal Ranger (St. Croix Sensory Inc., 2003). Responses of both devices during a measurement campaign were compared with odour predicted values by a dispersion model and with chemical data of emission marker’s analysis. The measurement test was performed in an anaerobic digestion plant located near Vicenza (Italy) and one typical odour source was a biofilter with an emission of 350 ouE/m3. The objective of this study is to compare different techniques (field olfactometry, marker’s analysis, dispersion model) for assessing the concentration of odour in ambient air. The analysis of results shows a clear and measurable influence of background odour in ambient air, resulting in higher odour levels when measured using field olfactometry than is predicted using chemical analysis or dispersion modeling. Furthermore, a good agreement was found between chemical data and predicted values from CALPUFF dispersion model.https://www.cetjournal.it/index.php/cet/article/view/6957
spellingShingle M. Benzo
A. Mantovani
A. Pittarello
Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
Chemical Engineering Transactions
title Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
title_full Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
title_fullStr Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
title_full_unstemmed Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
title_short Measurement of Odour Concentration of Immissions using a New Field Olfactometer and Markers’ Chemical Analysis
title_sort measurement of odour concentration of immissions using a new field olfactometer and markers chemical analysis
url https://www.cetjournal.it/index.php/cet/article/view/6957
work_keys_str_mv AT mbenzo measurementofodourconcentrationofimmissionsusinganewfieldolfactometerandmarkerschemicalanalysis
AT amantovani measurementofodourconcentrationofimmissionsusinganewfieldolfactometerandmarkerschemicalanalysis
AT apittarello measurementofodourconcentrationofimmissionsusinganewfieldolfactometerandmarkerschemicalanalysis